14-110000-00
Inspection ▶
Measure the current while removing the fuses one by one. If the current drops sharply when a certain
fuse is removed, inspect the affected circuit. 1.
Specified valuebelow 0.05A
6. INSPECTION - DARK CURRENT
Perform the basic inspection. -
Setting up the tester ▶
Preparation ▶
Disconnect the negative cable from the battery.
Set up the ammeter as shown in the figure above. 1.
2.
1) When Using Multi-tester
Connect the “+” probe to ground wiring and “-“probe to “-“terminal of battery.
14-12
Specified valuebelow 0.05A
Setting up the tester ▶
Preparation ▶
Disconnect the negative cable from the
battery.
Set up the ammeter and MSM as shown in
the figure above. 1.
2.
2) When Using MSM
Connect the negative cable to the
battery. 3.
Make sure to set up the tester while keeping
its polarity.
Measure the current while removing the fuses
one by one. If the current drops sharply when
a certain fuse is removed, inspect the affected
circuit.