13B-20V12 MR-372-J84-13B300$030.mif
DIESEL INJECTION
Fault finding – System operation13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
EOBD management (European On Board Diagnostic):
The EOBD system enables the detection of any faults relating to the vehicle emission control system
(EOBD EURO IV emission control standards exceeded).
This system should be active for the entire life of the vehicle.
1. Conditions for an EOBD fault appearing
An EOBD fault will be detected after 3 driving cycles.
It allows the driver to know whether the vehicle has a fault directly linked to the emission control system.
2. System faults displayed by the EOBD
Only a few faults are indicated by the EOBD system:
– DF002 Air temperature sensor circuit.
– DF004 Turbocharging pressure sensor circuit.
– DF011 Sensor feed voltage no. 1.
– DF012 Sensor feed voltage no. 2.
– DF013 Sensor feed voltage no. 3.
– DF026 Cylinder 1 injector control circuit.
– DF027 Cylinder 2 injector control circuit.
– DF028 Cylinder 3 injector control circuit.
– DF029 Cylinder 4 injector control circuit.
– DF054 Turbocharging solenoid valve control circuit.
– DF056 Air flow sensor circuit.
– DF107 Computer memory.
– DF200 Atmospheric pressure sensor.
– DF209 EGR position sensor circuit.
– DF272 EGR valve control circuit.
– DF569 Turbocharging circuit.
Some repair operations require programming to ensure that certain engine components function correctly.
Follow the programming procedures (see Replacement of components), if replacing the exhaust gas
recirculation valve or an injector.
3. Conditions for clearing an EOBD fault
An EOBD fault is cleared in several phases.
The fault present in the diagnostic tool will only be stored (following repair) after the vehicle has been driven
3times.
The EOBD warning light will only go out after these 3 driving cycles.
The instrument panel warning light coming on does not automatically mean that the system has a fault.
In order for the EOBD fault and display parameters to be cleared from the computer, the system must go
through 40 engine heating cycles.
An engine heating cycle is a driving cycle during which:
– the engine coolant temperature reaches at least 71.1°C,
– the engine coolant temperature varies by 22.2°C in relation to the engine starting temperature.
If one of these conditions is not fulfilled, the EOBD fault will still be present or stored in the injection
computer.

13B-29V12 MR-372-J84-13B300$060.mif
DIESEL INJECTION
Fault finding – Fault summary table13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Tool faultAssociated
DTCDiagnostic tool title
DF066611 Injector code(s)
DF0691655 Impact detected signal
DF0862600 Coolant pump relay control circuit
DF091500 Vehicle speed signal
DF098180 Fuel temperature sensor circuit
DF10762F Computer memory
DF119340 Camshaft sensor signal
DF120335 Engine speed sensor signal
DF151685 Main relay circuit
DF1652299 Accelerator pedal position sensor circuit
DF19516 Camshaft/engine speed sensor consistency
DF196225 Pedal sensor circuit gang 1
DF1982120 Pedal sensor circuit gang 2
DF2002226 Atmospheric pressure sensor
DF209409 EGR valve position sensor circuit
DF221830 Clutch switch signal
DF228571 Brake signal
DF24962B Injector control
DF2651201 Injector No. 1
DF2661202 Injector No. 2
DF2671203 Injector No.3
DF2681204 Injector No. 4
DF272487 EGR valve control circuit
DF2932269 Water in diesel fuel sensor
DF2972002 Particle filter
DF3042425 EGR by-pass circuit
DF308242F Clogged particle filter
DF309242A Particle filter downstream temp.* sensor
DF3102031 Particle filter upstream temp.* sensor
DF3111435 Failed regenerations limit exceeded
DF3121436 Speed request

13B-180
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$073.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF272
PRESENT
OR
STOREDEGR VALVE CONTROL CIRCUITCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
CC: Short circuit
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on,
– the engine is started,
– a road test.
Special notes:
If the fault is present:
–the EOBD (European On Board Diagnostic) warning light is lit,
– the EGR function is inhibited,
Use bornier Elé. 1681 for all operations on the engine management computer
connector.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
CO
NOTESNone.
Check the condition of the EGR valve (see Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2,
Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1460 or 169).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance between connections 3VP and 3VQ of component 1460 or 169.
If the resistance of the EGR valve is greater than 400 Ω, replace the valve.
After replacement, run command SC036 Reinitialise programming and select EGR valve to reinitialise the EGR
valve offsets.
EDC16CP33_V18_DF272 / EDC16CP33_V1C_DF272 / EDC16CP33_V54_DF272 / EDC16CP33_V20_DF272 / EDC16CP33_V58_DF272 /
EDC16CP33_V5C_DF272 / EDC16CP33_V24_DF272 / EDC16CP33_V04_DF272 / EDC16CP33_V08_DF272 / EDC16CP33_V44_DF272 /
EDC16CP33_V4C_DF272 / EDC16CP33_V34_DF272 / EDC16CP33_V38_DF272 / EDC16CP33_V74_DF272 / EDC16CP33_V28_DF272 /
EDC16CP33_V62_DF272 / EDC16CP33_V26_DF272 / EDC16CP33_V60_DF272
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74

13B-181
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$073.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF272
CONTINUED 1
Check the continuity of the following connections:
•3VP between components 120 and 1460 or 169,
•3VQ between components 120 and 1460 or 169.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact the Techline.
CC.0
CC.1
NOTESNone.
Check the condition of the EGR valve (see Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2,
Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1460 or 169).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance between connections 3VP and 3VQ of component 1460 or 169.
If the resistance of the EGR valve is less than 1 Ω or greater than 400 Ω, replace the EGR valve.
After replacement, run command SC036 Reinitialise programming and select EGR valve to reinitialise the EGR
valve offsets.
Check the insulation from + 12 V of the following connections:
•3VP between components 120 and 1460 or 169,
•3VQ between components 120 and 1460 or 169.
Check the insulation to earth of the following connections:
•3VP between components 120 and 1460 or 169,
•3VQ between components 120 and 1460 or 169.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring,
otherwise replace the wiring.
If the fault is still present, contact the Techline.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74

13B-182
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$073.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF272
CONTINUED 2
CCNOTESNone.
Check the condition of the EGR valve (see Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2,
Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1460 or 169).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance between connections 3VP and 3VQ of component 1460 or 169.
If the resistance of the EGR valve is less than 1 Ω or greater than 400 Ω, replace the EGR valve.
After replacement, run command SC036 Reinitialise programming and select EGR valve to reinitialise the EGR
valve offsets.
Check the insulation between the following connections:
•3VP between components 120 and 1460 or 169,
•3VQ between components 120 and 1460 or 169.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact the Techline.
1.DEF
NOTESSpecial notes:
This fault appears when the computer control section has
overheated.
Priorities when dealing with a number of faults:
Deal with CO, CC.O, CC.1 and CC first if they are present or
stored.
If the fault is still present, contact the Techline.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74

13B-191
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$073.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
diff.*: Differential
temp.*: Temperature
DF308
PRESENT
OR
STOREDCLOGGED PARTICLE FILTER
1.DEF: Maximum limit
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– the EGR function is inhibited,
– the vehicle performance is reduced,
–the level 1 warning light is lit and a warning message (or warning light) is displayed
on the instrument panel,
–the EOBD (European On Board Diagnostic) warning light is lit (except Vdiag 18,
1C, 24 and 54).
Priorities when dealing with a number of faults:
Deal with the following faults first:
– DF315 Particle filter differential pressure sensor if it is present.
– DF308 if DF315 is stored.
– DF717 Particle filter upstream pressure if it is present or stored.
– DF645 Damper valve position regulation if it is present or stored.
– DF272 EGR valve control circuit if it is present or stored.
– DF647 EGR valve position regulation if it is present or stored.
– DF309 Particle filter downstream temperature sensor if it is present or stored.
– DF899 Regeneration temperature threshold exceeded if it is present or stored.
– DF310 Particle filter upstream temperature sensor if it is present or stored.
– DF652 Turbine upstream temperature sensor circuit if it is present or stored.
EDC16CP33_V18_DF308 / EDC16CP33_V1C_DF308 / EDC16CP33_V54_DF308 / EDC16CP33_V20_DF308 / EDC16CP33_V58_DF308 /
EDC16CP33_V5C_DF308 / EDC16CP33_V24_DF308 / EDC16CP33_V28_DF308 / EDC16CP33_V62_DF308 / EDC16CP33_V26_DF308 /
EDC16CP33_V60_DF308
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62

13B-197
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$073.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
diff.*: Differential
temp.*: Temperature
DF311
PRESENT
OR
STOREDFAILED REGENERATIONS LIMIT EXCEEDED
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
–the level 1 warning light is lit,
– particle filter regenerations when driving are inhibited.
Priorities when dealing with a number of faults:
Deal with the following faults first:
– DF308 Particle filter clogged if it is present or stored.
– DF315 Particle filter diff.* pressure sensor if it is present or stored.
– DF717 Particle filter upstream pressure if it is present or stored.
– DF569 Turbocharging circuit if it is present or stored.
– DF309 Particle filter downstream temperature sensor if it is present or stored.
– DF899 Regeneration temperature threshold exceeded if it is present or stored.
– DF310 Particle filter upstream temperature sensor if it is present or stored.
– DF652 Turbine upstream temperature sensor circuit if it is present or stored.
– DF272 EGR valve control circuit if it is present or stored.
– DF647 EGR valve position regulation if it is present or stored.
EDC16CP33_V18_DF311 / EDC16CP33_V1C_DF311 / EDC16CP33_V54_DF311 / EDC16CP33_V20_DF311 / EDC16CP33_V58_DF311 /
EDC16CP33_V5C_DF311 / EDC16CP33_V24_DF311 / EDC16CP33_V26_DF311 / EDC16CP33_V60_DF311
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 54, 58, 5C, 60

13B-226
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF647
PRESENT
OR
STOREDEGR VALVE POSITION REGULATION1.DEF: EGR 1 offset inconsistency
2.DEF: EGR 2 offset inconsistency
3.DEF: Valve jammed closed
4.DEF: Valve jammed open
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on.
– the engine is started,
– a road test,
– if the air flowmeter temperature > 5°C.
Priorities when dealing with a number of faults:
– DF209 EGR valve position sensor circuit,
– DF046 Battery voltage,
– DF012 Sensor supply voltage no. 2,
– DF272 EGR valve control circuit.
Special notes:
–the level 1 and EOBD (European On Board Diagnostic) warning lights are lit for
1.DEF, 2.DEF, and 4.DEF
– only the EOBD (European On Board Diagnostic) warning light is lit for 3.DEF,
– the EGR function is inhibited by the engine management computer,
– reduced performance for 2.DEF and 3.DEF or 1.DEF and 2.DEF (for Vdiags 5C, 58
and 24, and 20, 26, 28, 60, 62).
Use bornier Elé. 1681 for all operations on the engine management computer
connector.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF647 / EDC16CP33_V1C_DF647 / EDC16CP33_V54_DF647 / EDC16CP33_V20_DF647 / EDC16CP33_V58_DF647 /
EDC16CP33_V5C_DF647 / EDC16CP33_V24_DF647 / EDC16CP33_V04_DF647 / EDC16CP33_V08_DF647 / EDC16CP33_V44_DF647 /
EDC16CP33_V4C_DF647 / EDC16CP33_V34_DF647 / EDC16CP33_V38_DF647 / EDC16CP33_V74_DF647 / EDC16CP33_V28_DF647 /
EDC16CP33_V62_DF647 / EDC16CP33_V26_DF647 / EDC16CP33_V60_DF647
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74