13B-211
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF333
PRESENT
OR
STOREDINJECTION -> AUTOMATIC TRANSMISSION CONNECTION
1.DEF: Multiplex network
NOTESSpecial notes:
– Use bornier Elé. 1681 for all operations on the engine management computer
connectors.
–Do not clear the fault before reading the contexts of the fault.
(see Wiring diagram Technical Note for Mégane II ph2, Scénic II ph2,
Espace IV ph2)
Conditions for applying the fault finding procedure to a stored fault:
– The fault is declared present if the EOBD (European On Board Diagnostic)
warning light is lit.
Check the multiplex network.
Check the condition of the automatic transmission computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, Espace IV ph2, component code 119).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, Espace IV ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation to earth, the continuity and absence of interference resistance on the following
connections:
•3MT between components 119 and 120,
•3MS between components 119 and 120.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, check that the automatic transmission computer is recognised by the CLIP diagnostic
tool.
If dialogue is not established (see MR 366, 372, 407, 23A, Automatic transmission).
EDC16CP33_V18_DF333 / EDC16CP33_V1C_DF333 / EDC16CP33_V54_DF333 / EDC16CP33_V20_DF333 / EDC16CP33_V58_DF333 /
EDC16CP33_V5C_DF333 / EDC16CP33_V24_DF333 / EDC16CP33_V28_DF333 / EDC16CP33_V62_DF333 / EDC16CP33_V26_DF333 /
EDC16CP33_V60_DF333
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62
13B-218
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF569
PRESENT
OR
STOREDTURBOCHARGING CIRCUIT
1.DEF: Turbocharging pressure too high
2.DEF: Turbocharging pressure too low
3DEF: Inconsistency
NOTESPriorities when dealing with a number of faults:
– DF054 Turbocharging solenoid valve control circuit
– DF004 Turbocharging pressure sensor circuit.
Conditions for applying the fault finding procedure to a stored fault:
If the fault is declared present after:
– the ignition is switched on,
– starting for 2.DEF,
– a road test,
– in turbo regulation phase for 1.DEF,
– engine speed > 3000 rpm for 1.DEF,
– system flow > 20 mg/st for 1.DEF.
Special notes:
Use bornier Elé.1681 for any operations on the injection computer connectors.
If the fault is present:
– particle filter regenerations are inhibited (for Vdiag 18, 1C, 54, 20, 58, 5C, 24 only),
– engine torque limited,
– turbocharging regulation is inhibited,
– the EGR function is inhibited,
–the level 1 and EOBD (European On Board Diagnostic) warning lights are lit.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF569 / EDC16CP33_V1C_DF569 / EDC16CP33_V54_DF569 / EDC16CP33_V20_DF569 / EDC16CP33_V58_DF569 /
EDC16CP33_V5C_DF569 / EDC16CP33_V24_DF569 / EDC16CP33_V04_DF569 / EDC16CP33_V08_DF569 / EDC16CP33_V44_DF569 /
EDC16CP33_V4C_DF569 / EDC16CP33_V34_DF569 / EDC16CP33_V38_DF569 / EDC16CP33_V74_DF569 / EDC16CP33_V28_DF569 /
EDC16CP33_V62_DF569 / EDC16CP33_V26_DF569 / EDC16CP33_V60_DF569
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
13B-219
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF569
CONTINUED 1
1.DEF
2.DEF
3.DEF
NOTESNone.
If the specification of this fault is: 2.DEF: Turbocharging pressure too low, apply test 6: Fuel circuit return
valve check.
Continue fault finding, regardless of whether or not the fuel return rail has been replaced.
For the other specifications, move on to the next step.
If the loss of power was not noted during slight acceleration and if there was a loss of engine power during each
acceleration at full load, replace the diesel fuel injector return rail and its overpressure valve (see MR364
(Mégane II ph2), MR370 (Scénic II ph2), MR 395 (Laguna II ph2), 402 (Vel Satis ph2), 405 (Espace IV ph2)
Mechanical, 13B, Diesel fuel injector return rail: Removal - Refitting).
Check the condition of the turbocharging pressure sensor connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1071).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
13B-221
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF645
PRESENT
OR
STOREDDAMPER VALVE POSITION REGULATION
1.DEF: Data inconsistency
2.DEF: Value outside permitted tolerance values
3.DEF: Damper valve jammed open
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– with the engine running,
– the battery voltage X > 8V.
Priorities when dealing with a number of faults:
– DF038 Computer,
– DF323 Damper valve,
– DF012 Sensor supply voltage no. 2,
– DF646 Damper valve position sensor.
Special notes:
If the fault is present:
–the level 1 warning light is lit (for Vdiag 20, 58, 24, 5C, 26, 28, 60 and 62),
– particle filter regeneration is inhibited.
Use bornier Elé. 1681 for all operations on the engine management computer
connector.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
Check the condition and connection of the damper valve connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1461).
Check the condition and connection of the engine management computer connector (see Wiring Diagram
Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code
120).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33_V18_DF645 / EDC16CP33_V1C_DF645 / EDC16CP33_V54_DF645 / EDC16CP33_V20_DF645 / EDC16CP33_V58_DF645 /
EDC16CP33_V5C_DF645 / EDC16CP33_V24_DF645 / EDC16CP33_V04_DF645 / EDC16CP33_V08_DF645 / EDC16CP33_V44_DF645 /
EDC16CP33_V4C_DF645 / EDC16CP33_V34_DF645 / EDC16CP33_V38_DF645 / EDC16CP33_V74_DF645 / EDC16CP33_V28_DF645 /
EDC16CP33_V62_DF645 / EDC16CP33_V26_DF645 / EDC16CP33_V60_DF645
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
13B-223
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF646
PRESENT
OR
STOREDDAMPER VALVE POSITION SENSORCC.0: Short circuit to earth
CO.0: Open circuit or short circuit to earth
CO.1: Open circuit or short circuit to +12 V
1.DEF: Open circuit or short circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the engine is started,
– a road test.
Priorities when dealing with a number of faults:
– DF012 Sensor supply voltage no. 2.
Special notes:
If the fault is present:
–the level 1 warning light is lit (for Vdiag 20, 58, 24, 5C, 26, 28, 60 and 62),
– particle filter regeneration is inhibited.
Use bornier Elé. 1681 for all operations on the engine management computer
connector.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
CO.1
1.DEF
NOTESNone.
Check the condition of the damper valve connector (see Wiring Diagram Technical Note, Laguna II ph2, Vel
Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1461).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33_V18_DF646 / EDC16CP33_V1C_DF646 / EDC16CP33_V54_DF646 / EDC16CP33_V20_DF646 / EDC16CP33_V58_DF646 /
EDC16CP33_V5C_DF646 / EDC16CP33_V24_DF646 / EDC16CP33_V04_DF646 / EDC16CP33_V08_DF646 / EDC16CP33_V44_DF646 /
EDC16CP33_V4C_DF646 / EDC16CP33_V34_DF646 / EDC16CP33_V38_DF646 / EDC16CP33_V74_DF646 / EDC16CP33_V28_DF646 /
EDC16CP33_V62_DF646 / EDC16CP33_V26_DF646 / EDC16CP33_V60_DF646
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
13B-226
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF647
PRESENT
OR
STOREDEGR VALVE POSITION REGULATION1.DEF: EGR 1 offset inconsistency
2.DEF: EGR 2 offset inconsistency
3.DEF: Valve jammed closed
4.DEF: Valve jammed open
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on.
– the engine is started,
– a road test,
– if the air flowmeter temperature > 5°C.
Priorities when dealing with a number of faults:
– DF209 EGR valve position sensor circuit,
– DF046 Battery voltage,
– DF012 Sensor supply voltage no. 2,
– DF272 EGR valve control circuit.
Special notes:
–the level 1 and EOBD (European On Board Diagnostic) warning lights are lit for
1.DEF, 2.DEF, and 4.DEF
– only the EOBD (European On Board Diagnostic) warning light is lit for 3.DEF,
– the EGR function is inhibited by the engine management computer,
– reduced performance for 2.DEF and 3.DEF or 1.DEF and 2.DEF (for Vdiags 5C, 58
and 24, and 20, 26, 28, 60, 62).
Use bornier Elé. 1681 for all operations on the engine management computer
connector.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF647 / EDC16CP33_V1C_DF647 / EDC16CP33_V54_DF647 / EDC16CP33_V20_DF647 / EDC16CP33_V58_DF647 /
EDC16CP33_V5C_DF647 / EDC16CP33_V24_DF647 / EDC16CP33_V04_DF647 / EDC16CP33_V08_DF647 / EDC16CP33_V44_DF647 /
EDC16CP33_V4C_DF647 / EDC16CP33_V34_DF647 / EDC16CP33_V38_DF647 / EDC16CP33_V74_DF647 / EDC16CP33_V28_DF647 /
EDC16CP33_V62_DF647 / EDC16CP33_V26_DF647 / EDC16CP33_V60_DF647
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
13B-229
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF651
PRESENT
OR
STOREDTURBINE UPSTREAM PRESSURE SENSOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistency
NOTESConditions for applying the fault finding procedure to a stored fault:
If the fault is declared present after:
– With the ignition on,
– when the engine is running.
Special notes:
If the fault is present:
– engine torque limited,
– the EGR function is inhibited by the engine management computer,
– the vehicle performance is reduced,
– particle filter regeneration is inhibited,
–the level 1 warning light is illuminated,
–the EOBD (European On Board Diagnostic) warning light is lit (for Vdiag 5C, 58,
24 and 20 (only for M9R761, M9R722, M9R760 and M9R724)).
Priorities when dealing with a number of faults:
DF011 Sensor supply voltage no. 1.
CO.0
NOTESNone.
Check the condition of the turbine upstream pressure sensor connector (component code 1299).
Check the condition of the engine management computer connector (component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33_V18_DF651 / EDC16CP33_V1C_DF651 / EDC16CP33_V54_DF651 / EDC16CP33_V20_DF651 / EDC16CP33_V58_DF651 /
EDC16CP33_V5C_DF651 / EDC16CP33_V24_DF651 / EDC16CP33_V28_DF651 / EDC16CP33_V62_DF651 / EDC16CP33_V26_DF651 /
EDC16CP33_V60_DF651
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62
13B-232
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF652
PRESENT
OR
STOREDTURBINE UPSTREAM TEMPERATURE SENSOR CIRCUIT
CC.0: Short circuit to earth
CO.1: Open circuit or short circuit to +12 V
NOTESConditions for applying fault finding procedures to stored faults:
The fault becomes present if:
– the ignition is on (CC.0) or after a road test with the engine warm (CO.1).
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– the vehicle performance is reduced,
– temperature regulation upstream of the particle filter is inhibited,
–the level 1 warning light is illuminated,
–the EOBD (European On Board Diagnostic) warning light is lit (for Vdiag 5C, 58,
24 and 20).
CC.0
NOTESNone.
Check the condition of the turbine upstream temperature sensor connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1589).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation from earth of the following connections:
•3ABS between components 120 and 1589,
•3ABT between components 120 and 1589.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If fault is still present, replace the turbine upstream temperature sensor
EDC16CP33_V18_DF652 / EDC16CP33_V1C_DF652 / EDC16CP33_V54_DF652 / EDC16CP33_V20_DF652 / EDC16CP33_V58_DF652 /
EDC16CP33_V5C_DF652 / EDC16CP33_V24_DF652 / EDC16CP33_V28_DF652 / EDC16CP33_V62_DF652 / EDC16CP33_V26_DF652 /
EDC16CP33_V60_DF652
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62