13B-249
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF898
PRESENT
OR
STOREDPRESSURE REGULATOR CIRCUIT ON RAILCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault reappears after:
– the ignition is switched on,
– the regulator is controlled using command AC225 Rail pressure regulator.
Special notes:
The rail pressure regulator (DRV) is built into the high pressure rail.
The DF898 Rail pressure regulator circuit depends on the pressure regulator on the
rail (DRV).
If the fault is present:
– the quantity of fuel injected is limited and the engine speed is limited to 3000 rpm:
CO, CC.1, 1.DEF,
–the level 2 warning light will be lit,
– the engine stops immediately for CO, CC.1, 1.DEF,
– the engine stops after a few minutes for CC.0,
– the rail pressure is regulated by the pump pressure regulator (MPROP).
Use bornier Elé. 1681 for all operations on the engine management computer
connectors.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF898 / EDC16CP33_V1C_DF898 / EDC16CP33_V54_DF898 / EDC16CP33_V20_DF898 / EDC16CP33_V58_DF898 /
EDC16CP33_V5C_DF898 / EDC16CP33_V24_DF898 / EDC16CP33_V04_DF898 / EDC16CP33_V08_DF898 / EDC16CP33_V44_DF898 /
EDC16CP33_V4C_DF898 / EDC16CP33_V34_DF898 / EDC16CP33_V38_DF898 / EDC16CP33_V74_DF898 / EDC16CP33_V28_DF898 /
EDC16CP33_V62_DF898 / EDC16CP33_V26_DF898 / EDC16CP33_V60_DF898
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74