13B-201
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$104.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
*ADAC: Trip Computer
DF1020
PRESENT
OR
STOREDENGINE OIL DILUTION
1. DEF: Above maximum threshold
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the engine is started.
– a road test.
Special notes:
If the fault is present:
– particle filter regeneration is inhibited.
Use bornier Elé. 1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
Note:
This fault is activated in case of considerable oil dilution due to a significant number of particle filter regenerations.
Carry out the following:
– An oil change (see MR 364 (Mégane II) or MR 370 (Scénic II), Mechanical, 10A Engine and peripherals,
Engine oil: Draining – Filling),
– reset the oil wear meter,
– clear the faults.
Reset the oil wear meter after the oil change:
It will be necessary to reinitialise the display of the trip computer.
With the ignition on:
– hold down the TC* button for 5 s.
Re-initialisation has worked when the on-board computer no longer displays the key.
If this is not the case, restart the procedure.
Specific case:
If an oil change is performed before the oil service interval warning is exceeded, reinitialise the display.
EDC16C36_V50_DF1020/EDC16C36_V58_DF1020EDC16 C36
Program No.: 91
Vdiag No.: 50, 58