13B - 25
DIESEL INJECTION
Fault finding - Fault summary table13B
V10 MR-372-J84-13B150$235.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
FAULT WARNING LIGHT MANAGEMENT (continued)
Tool
fault
Associated
DTCDiagnostic tool titleLevel 1
fault warning
light (Orange
heater plugs
“on” indicator
light)Level 2 fault
warning light
(Red overheating
warning light)No fault
warning
light litOBD
warning
light lit
DF091 500Vehicle speed signal ... ... 1.DEF/
2.DEF/
3.DEF/
4.DEF/5.DEF...
DF097 340Camshaft sensor circuit 1.DEF/2.DEF
DF098 180Fuel temperature sensor circuit ... ... CC.0 / CO.1
DF114 400EGR solenoid valve circuit ... ... 1.DEF/2.DEF
DF118 409EGR solenoid valve servo-
control... ... 1.DEF/2.DEF ...
DF119 365Camshaft sensor signal ... ... 1.DEF/2.DEF ...
DF120 385Engine speed sensor signal ... 1.DEF/2.DEF ...
DF209 486EGR valve position sensor circuit 1.DEF CC.1/CO.0
DF250 C122ESP function ... ... 1.DEF/2.DEF ...
DF272 403EGR valve control circuit CC.0 CC.1 / CO/
1.DEFCC.0
DF276 611Injector code programming 1.DEF/2.DEF
DF530 148AEGR programming adaptives X
DF619 487EGR valve jammed open X ... ... ...
DF620 148BEGR valve fouled X ... ... ...
DF621 2413EGR valve is jammed open
(OBD fault)... ... ... X
DF622 2142EGR valve jammed open ... ... X ...
DF1070 534Cold loop
13B-105
DIESEL INJECTION
Fault finding - Interpretation of faults
13B
V10 MR-372-J84-13B150$376.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 48
DF620
PRESENT
OR
STOREDEGR VALVE FOULED
WARNING
This fault only appears in Vdiag 48.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– a road test,
– an actuator command AC002 EGR solenoid valve.
Special notes:
The EGR and turbocharging functions are inhibited.
The level 1 warning light comes on.
Use bornier Ele. 1681 for all operations on the injection computer connectors.
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Clear any stored faults.
Run command RZ002 EGR Adaptives to reinitialise the valve operating values.
Switch off the ignition and wait for the engine immobiliser warning light to start flashing.
Switch the ignition on again and check the system faults.
If the fault is still present:
– remove the EGR valve, and then reconnect it,
– check that the movement of the valve is not being blocked by a particle,
– check that the valve is not jammed or stuck in one position,
– run command AC002 EGR solenoid valve,
– check the movement of the solenoid valve,
– check that the solenoid valve is completely closed,
– if there is no movement, or if the valve is seized and cannot be repaired, replace the EGR solenoid valve.
AFTER REPAIRDeal with any faults.
Carry out a road test, then check with the diagnostic tool.
EDC16_V44_DF620/EDC16_V48_DF620/EDC16_V4C_DF620