LAN-190
< DTC/CIRCUIT DIAGNOSIS >[CAN SYSTEM (TYPE 3)]
IPDM-E BRANCH LINE CIRCUIT
IPDM-E BRANCH LINE CIRCUIT
Diagnosis ProcedureINFOID:0000000006256348
1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the following terminals and connectors fo r damage, bend and loose connection (unit side and con-
nector side).
-IPDME/R
- Harness connector E105
- Harness connector M77
- Harness connector M19 (Without ICC system)
- Harness connector B2 (Without ICC system)
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of IPDM E/R.
2. Check the resistance between the IPDM E/R harness connector terminals.
Is the measurement value within the specification?
YES >> GO TO 3.
NO >> Repair the IPDM E/R branch line.
3.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the IPDM E/R. Refer to PCS-31, "
Diagnosis Procedure".
Is the inspection result normal?
YES (Present error)>>Replace the IPDM E/R. Refer to PCS-32, "Removal and Installation".
YES (Past error)>>Error was detec ted in the IPDM E/R branch line.
NO >> Repair the power supply and the ground circuit.
IPDM E/R harness connector Resistance (Ω)
Connector No. Terminal No.
E13 27 26 Approx. 108 – 132
Revision: 2010 May2011 QX56
LAN
ADP BRANCH LINE CIRCUITLAN-191
< DTC/CIRCUIT DIAGNOSIS > [CAN SYSTEM (TYPE 3)]
C
D
E
F
G H
I
J
K L
B A
O P
N
ADP BRANCH LINE CIRCUIT
Diagnosis ProcedureINFOID:0000000006256349
1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cabl e from the negative terminal.
3. Check the following terminals and connectors for damage, bend and loose connection (unit side and con- nector side).
- Driver seat control unit
- Harness connector B460
- Harness connector B24
- CAN gateway (With ICC system)
Is the inspection result normal?
YES (With ICC system)>>GO TO 2.
YES (Without ICC system)>>GO TO 3.
NO >> Repair the terminal and connector.
2.CHECK HARNESS CONTI NUITY (OPEN CIRCUIT)
1. Disconnect the connector of CAN gateway.
2. Check the continuity between the CAN gateway harness connector terminals.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Check the harness and repair the root cause (CAN communication circuit 2). Refer to LAN-57,
"System Diagram".
3.CHECK HARNESS FOR OPEN CIRCUIT
1. Connect the connector of CAN gateway. (With ICC system)
2. Disconnect the connector of driver seat control unit.
3. Check the resistance between the driver s eat control unit harness connector terminals.
Is the measurement value within the specification?
YES >> GO TO 4.
NO >> Repair the driver seat control unit branch line.
4.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the driver seat control unit. Refer to ADP-67, "
DRIVER SEAT
CONTROL UNIT : DiagnosisProcedure".
Is the inspection result normal?
YES (Present error)>>Replace the driver seat control unit. Refer to ADP-135, "Removal and Installation".
YES (Past error)>>Error was detected in the driver seat control unit branch line.
NO >> Repair the power supply and the ground circuit.
CAN gateway harness connector Continuity
Connector No. Terminal No.
M125 46Existed
10 12 Existed
Driver seat control unit harness connector Resistance (Ω)
Connector No. Terminal No.
B451 1 17 Approx. 54 – 66
Revision: 2010 May2011 QX56
LAN-192
< DTC/CIRCUIT DIAGNOSIS >[CAN SYSTEM (TYPE 3)]
E-SUS BRANCH LINE CIRCUIT
E-SUS BRANCH LINE CIRCUIT
Diagnosis ProcedureINFOID:0000000006256351
1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the following terminals and connectors fo r damage, bend and loose connection (unit side and con-
nector side).
- Air levelizer control module
- CAN gateway (With ICC system)
Is the inspection result normal?
YES (With ICC system)>>GO TO 2.
YES (Without ICC sy stem)>>GO TO 3.
NO >> Repair the terminal and connector.
2.CHECK HARNESS CONTI NUITY (OPEN CIRCUIT)
1. Disconnect the connector of CAN gateway.
2. Check the continuity between the CA N gateway harness connector terminals.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Check the harness and repair the root cause (CAN communication circuit 2). Refer to LAN-57,
"System Diagram".
3.CHECK HARNESS FOR OPEN CIRCUIT
1. Connect the connector of CAN gateway. (With ICC system)
2. Disconnect the connector of air levelizer control module.
3. Check the resistance between the air leveliz er control module harness connector terminals.
Is the measurement value within the specification?
YES >> GO TO 4.
NO >> Repair the air levelizer control module branch line.
4.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the air levelizer control module. Refer to SCS-89,
"DiagnosisProcedure".
Is the inspection result normal?
YES (Present error)>>Replace the air levelizer control module. Refer to SCS-94, "Removal and Installation".
YES (Past error)>>Error was detected in t he air levelizer control module branch line.
NO >> Repair the power supply and the ground circuit.
CAN gateway harness connector Continuity
Connector No. Terminal No.
M125 46Existed
10 12 Existed
Air levelizer control mo dule harness connector
Resistance (Ω)
Connector No. Terminal No.
B84 16 7 Approx. 54 – 66
Revision: 2010 May2011 QX56
LAN
PWBD BRANCH LINE CIRCUITLAN-193
< DTC/CIRCUIT DIAGNOSIS > [CAN SYSTEM (TYPE 3)]
C
D
E
F
G H
I
J
K L
B A
O P
N
PWBD BRANCH LINE CIRCUIT
Diagnosis ProcedureINFOID:0000000006256353
1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cabl e from the negative terminal.
3. Check the following terminals and connectors for damage, bend and loose connection (unit side and con- nector side).
- Automatic back door control module
- CAN gateway (With ICC system)
Is the inspection result normal?
YES (With ICC system)>>GO TO 2.
YES (Without ICC system)>>GO TO 3.
NO >> Repair the terminal and connector.
2.CHECK HARNESS CONTI NUITY (OPEN CIRCUIT)
1. Disconnect the connector of CAN gateway.
2. Check the continuity between the CAN gateway harness connector terminals.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Check the harness and repair the root cause (CAN communication circuit 2). Refer to LAN-57,
"System Diagram".
3.CHECK HARNESS FOR OPEN CIRCUIT
1. Connect the connector of CAN gateway. (With ICC system)
2. Disconnect the connector of automatic back door control module.
3. Check the resistance between the automatic bac k door control module harness connector terminals.
Is the measurement value within the specification?
YES >> GO TO 4.
NO >> Repair the automatic back door control module branch line.
4.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of t he automatic back door control module. Refer to DLK-116,
"AUTOMATIC BACK DOOR CONTROL UNIT : Diagnosis Procedure".
Is the inspection result normal?
YES (Present error)>>Replace the automat ic back door control module. Refer to DLK-262, "Removal and
Installation".
YES (Past error)>>Error was detected in the automatic back door control module branch line.
NO >> Repair the power supply and the ground circuit.
CAN gateway harness connector Continuity
Connector No. Terminal No.
M125 46Existed
10 12 Existed
Automatic back door control module harness connector Resistance (Ω)
Connector No. Terminal No.
B26 7 6 Approx. 54 – 66
Revision: 2010 May2011 QX56
LAN-194
< DTC/CIRCUIT DIAGNOSIS >[CAN SYSTEM (TYPE 3)]
CAN COMMUNICATION CIRCUIT
CAN COMMUNICATION CIRCUIT
Diagnosis ProcedureINFOID:0000000006256359
1.CONNECTOR INSPECTION
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Disconnect all the unit connectors on CAN communication circuit.
4. Check terminals and connectors for damage, bend and loose connection.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair the terminal and connector.
2.CHECK HARNESS CONTI NUITY (SHORT CIRCUIT)
Check the continuity between t he data link connector terminals.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Check the harness and repair the root cause.
3.CHECK HARNESS CONTI NUITY (SHORT CIRCUIT)
Check the continuity between the data link connector and the ground.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Check the harness and repair the root cause.
4.CHECK ECM AND IPDM E/R TERMINATION CIRCUIT
1. Remove the ECM and the IPDM E/R.
2. Check the resistance between the ECM terminals.
3. Check the resistance between the IPDM E/R terminals.
Is the measurement value within the specification?
YES >> GO TO 5.
NO >> Replace the ECM and/or the IPDM E/R.
5.CHECK SYMPTOM
Connect all the connectors. Check if the symptoms descri bed in the “Symptom (Results from interview with
customer)” are reproduced.
Data link connector Continuity
Connector No. Terminal No.
M4 6 14 Not existed
Data link connector
GroundContinuity
Connector No. Terminal No.
M4 6 Not existed
14 Not existed
ECM Resistance (Ω)
Te r m i n a l N o .
146 151 Approx. 108 – 132
IPDM E/R Resistance (Ω)
Te r m i n a l N o .
27 26 Approx. 108 – 132
Revision: 2010 May2011 QX56
LAN-202
< DTC/CIRCUIT DIAGNOSIS >[CAN SYSTEM (TYPE 4)]
ECM BRANCH LINE CIRCUIT
ECM BRANCH LINE CIRCUIT
Diagnosis ProcedureINFOID:0000000006256373
1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the ECM for damage, bend and loose connection (unit side and connector side).
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of ECM.
2. Check the resistance between the ECM harness connector terminals.
Is the measurement value within the specification?
YES >> GO TO 3.
NO >> Repair the ECM branch line.
3.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the ECM. Refer to EC-168, "
Diagnosis Procedure".
Is the inspection result normal?
YES (Present error)>>Replace the ECM. Refer to EC-535, "Removal and Installation".
YES (Past error)>>Error was detected in the ECM branch line.
NO >> Repair the power supply and the ground circuit.
ECM harness connector Resistance (Ω)
Connector No. Terminal No.
E80 146 151 Approx. 108 – 132
Revision: 2010 May2011 QX56
LAN
4WD BRANCH LINE CIRCUITLAN-203
< DTC/CIRCUIT DIAGNOSIS > [CAN SYSTEM (TYPE 4)]
C
D
E
F
G H
I
J
K L
B A
O P
N
4WD BRANCH LINE CIRCUIT
Diagnosis ProcedureINFOID:0000000006256374
1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cabl e from the negative terminal.
3. Check the terminals and connectors of the trans fer control unit for damage, bend and loose connection
(unit side and connector side).
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of transfer control unit.
2. Check the resistance between the transfe r control unit harness connector terminals.
Is the measurement value within the specification?
YES >> GO TO 3.
NO >> Repair the transfer control unit branch line.
3.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the transfer control unit. Refer to DLN-93, "
Diagnosis Proce-
dure".
Is the inspection result normal?
YES (Present error)>>Replace the transfer control unit. Refer to DLN-107, "Removal and Installation".
YES (Past error)>>Error was detected in the transfer control unit branch line.
NO >> Repair the power supply and the ground circuit.
Transfer control unit harness connector Resistance (Ω)
Connector No. Terminal No.
E59 12 13 Approx. 54 – 66
Revision: 2010 May2011 QX56
LAN-204
< DTC/CIRCUIT DIAGNOSIS >[CAN SYSTEM (TYPE 4)]
ABS BRANCH LINE CIRCUIT
ABS BRANCH LINE CIRCUIT
Diagnosis ProcedureINFOID:0000000006256375
1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the ABS act uator and electric unit (control unit) for damage, bend
and loose connection (unit side and connector side).
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of ABS actuat or and electric unit (control unit).
2. Check the resistance between the ABS actuator and electric unit (control unit) harness connector termi-
nals.
Is the measurement value within the specification?
YES >> GO TO 3.
NO >> Repair the ABS actuator and electric unit (control unit) branch line.
3.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the AB S actuator and electric unit (control unit). Refer to
BRC-113, "
Diagnosis Procedure".
Is the inspection result normal?
YES (Present error)>>Replace the ABS actuator and electric unit (control unit). Refer to BRC-137, "Removal
and Installation".
YES (Past error)>>Error was detected in the ABS ac tuator and electric unit (control unit) branch line.
NO >> Repair the power supply and the ground circuit.
ABS actuator and electric unit (c ontrol unit) harness connector
Resistance (Ω)
Connector No. Terminal No.
E36 41 27 Approx. 54 – 66
Revision: 2010 May2011 QX56