PETROL INJECTION
Fault finding - Interpretation of commands
17B
17B - 216
PETROL INJECTION
Fault finding - Interpretation of commands
17B
17B - 216V9 MR-372-J84-17B050$799.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
AC079
ACTUATOR STATIC TEST
NOTESThere must be no present or stored faults.
Switch the ignition on and run command AC079 Actuator static test.
If the following actuators are not working, apply the interpretation of the associated fault:
– Fuel pump relay, apply the interpretation of DF085 Fuel pump relay circuit.
– The motorised throttle, apply the interpretation of DF079 Motorised throttle valve servo control.
– The electric coolant pump, apply the interpretation of DF570 Coolant pump relay.
–Upstream O
2 sensor heating, apply the interpretation of DF601 Upstream O2 sensor heating power circuit.
– Downstream O
2 sensor heating, apply the interpretation of DF602 Downstream O2 sensor heating power
circuit.
AFTER REPAIRRepeat the conformity check from the start.
S3000_V4C_AC079/S3000_V54_AC079