DTC P0222, P0223 TP SENSOR
EC-781
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
1. Disconnect electric throttle c
ontrol actuator (1) harness connec-
tor.
- : Vehicle front
2. Turn ignition switch ON.
3. Check voltage between electric throttle control actuator terminal 2 and ground with CONSULT-III or tester.
OK or NG
OK >> GO TO 3.
NG >> Repair open circuit or short to ground or short to power in harness connectors.
3.CHECK THROTTLE POSITION SENSOR 1 GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 36 and electric throttle control actuator terminal 4.
Refer to Wiring Diagram.
4. Also check harness for short to ground or short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK THROTTLE POSITION SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal 33 and electric throttle control actuator terminal 1.
Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK THROTTLE POSITION SENSOR
Refer to EC-782, "
Component Inspection".
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6.REPLACE ELECTRIC THROTTLE CONTROL ACTUATOR
1. Replace the electric throttle control actuator.
2. Perform EC-580, "
Throttle Valve Closed Position Learning".
3. Perform EC-580, "
Idle Air Volume Learning".
PBIB3325E
Voltage: Approximately 5 V
PBIB3311E
Continuity should exist.
Continuity should exist.
Revision: January 20102010 Versa
DTC P0327, P0328 KSEC-791
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Diagnosis ProcedureINFOID:0000000005532634
1.CHECK KNOCK SENSOR INPUT SIGNAL CIRCUIT-I
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check resistance between ECM terminal 37 and ground. Refer to Wiring Diagram. NOTE:
It is necessary to use an ohmmeter which can measure more than 10 MΩ .
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> GO TO 2.
2.CHECK KNOCK SENSOR INPUT SIGNAL CIRCUIT-II
1. Disconnect knock sensor (1) harness connector.
- : Vehicle front
2. Check harness continuity between ECM terminal 37 and knock sensor terminal 1. Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 3.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK KNOCK SENSOR
Refer to EC-792, "
Component Inspection".
OK or NG
OK >> GO TO 6.
NG >> Replace knock sensor.
4.CHECK GROUND CONNECTIONS
Loosen and retighten ground screws on the body.
Refer to EC-638, "
Ground Inspection".
TERMI-
NAL NO. WIRE
COLOR ITEM
CONDITION DATA (DC Voltage)
37 W Knock sensor [Engine is running]
• Idle speed
Approximately 2.5 V
40 — Sensor ground
(Knock sensor) [Engine is running]
•
Warm-up condition
• Idle speed Approximately 0 V
Resistance: Approximately 532 - 588 k
Ω [at 20 °C (68° F)]
Continuity should exist.
PBIB3264E
BBIA0698E
Revision: January 20102010 Versa
DTC P0335 CKP SENSOR (POS)EC-797
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
5.CHECK COMPONENTS
Check the following.
• Refrigerant pressure sensor. (Refer to EC-1030
.)
• EVAP control system pressure sensor. (Refer to EC-850
.)
OK or NG
OK >> GO TO 6.
NG >> Replace malfunctioning components.
6.CHECK APP SENSOR
Refer to EC-969, "
Component Inspection".
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7.REPLACE ACCELERATOR PEDAL ASSEMBLY
1. Replace accelerator pedal assembly.
2. Perform EC-580, "
Accelerator Pedal Released Position Learning".
3. Perform EC-580, "
Throttle Valve Closed Position Learning".
4. Perform EC-580, "
Idle Air Volume Learning".
>> INSPECTION END
8.CHECK CKP SENSOR (POS) GRO UND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between CKP sens or (POS) terminal 2 and ECM terminal 62.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
9.CHECK CKP SENSOR (POS) INPUT SI GNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between CKP s ensor (POS) terminal 3 and ECM terminal 61.
Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 10.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
10.CHECK CRANKSHAFT POSI TION SENSOR (POS)
Refer to EC-798, "
Component Inspection".
OK or NG
OK >> GO TO 11.
NG >> Replace crankshaft position sensor (POS).
11 .CHECK GEAR TOOTH
Visually check for chipping signal plate gear tooth.
OK or NG
OK >> GO TO 12.
NG >> Replace the signal plate. Continuity should exist.
Continuity should exist.
Revision: January 20102010 Versa
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-827
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
4. Check voltage between EVAP canister purge volume control
solenoid valve terminal 1 and ground with CONSULT-III or
tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2.DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors E8, F8
• Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 9 and EVAP canister purge volume control solenoid valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK EVAP CONTRO L SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness con-
nector.
- EVAP control system pressure sensor (1)
- EVAP canister (2)
- EVAP canister vent control valve (3)
2. Check connectors for water.
OK or NG
OK >> GO TO 5.
NG >> Replace EVAP control system pressure sensor.
5.CHECK EVAP CONTROL SYS TEM PRESSURE SENSOR
Refer to EC-850, "
Component Inspection".
OK or NG
OK (With CONSULT-III)>>GO TO 6.
OK (Without CONSULT-III)>>GO TO 7.
NG >> Replace EVAP control system pressure sensor.
6.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
With CONSULT-III
1. Turn ignition switch OFF.
2. Reconnect harness connectors disconnected.
3. Start engine. Voltage: Battery voltage
PBIB0080E
Continuity should exist.
Water should not exist.
BBIA0693E
Revision: January 20102010 Versa
EC-834
< SERVICE INFORMATION >[MR18DE]
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
4. Check voltage between EVAP canister purge volume control
solenoid valve terminal 1 and ground with CONSULT-III or
tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2.DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors E8, F8
• Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK EVAP CANISTER PURGE VOLUME CONTRO L SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 9 and EVAP canister purge volume control solenoid
valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK (With CONSULT-III)>>GO TO 4.
OK (Without CONSULT-III)>>GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-III
1. Reconnect all harness connectors disconnected.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-III. Check that engine speed var- ies according to the valve opening.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
Refer to EC-829, "
Component Inspection".
OK or NG
OK >> GO TO 6.
NG >> Replace EVAP canister purge volume control solenoid valve.
6.CHECK INTERMITTENT INCIDENT
Refer to EC-632
.
>> INSPECTION END
Component InspectionINFOID:0000000005532681
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Voltage: Battery voltage
SEF206W
Continuity should exist.
Revision: January 20102010 Versa
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-839
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
4. Check voltage between EVAP canister vent control valve termi-
nal 1 and ground with CONSULT-III or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4.DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors E8, F8
• Harness connectors E7, M69
• Harness connectors M12, B101
• Harness for open or short between EVAP cani ster vent control valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 28 and EVAP canister vent control valve terminal 2.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6.DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors E8, F8
• Harness connectors E7, M69
• Harness connectors M13, B102
• Harness for open or short between EVAP c anister vent control valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
7.CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EV AP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK >> GO TO 8.
NG >> Clean the rubber tube using an air blower.
8.CHECK DRAIN FILTER
Refer to EC-814, "
Component Inspection".
OK or NG
OK >> GO TO 9.
NG >> Replace drain filter.
9.CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-840, "
Component Inspection".
Voltage: Battery voltage
PBIB0080E
Continuity should exist.
Revision: January 20102010 Versa
EC-850
< SERVICE INFORMATION >[MR18DE]
DTC P0451 EVAP CONTROL
SYSTEM PRESSURE SENSOR
• Refrigerant pressure sensor (Refer to MTC-38.)
• Crankshaft position sensor (POS) (Refer to EC-798, "
Component Inspection".)
OK or NG
OK >> GO TO 5.
NG >> Replace malfunctioning components.
5.CHECK APP SENSOR
Refer to EC-969, "
Component Inspection".
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6.REPLACE ACCELERATOR PEDAL ASSEMBLY
1. Replace accelerator pedal assembly.
2. Perform EC-580, "
Accelerator Pedal Released Position Learning".
3. Perform EC-580, "
Throttle Valve Closed Position Learning".
4. Perform EC-580, "
Idle Air Volume Learning".
>> INSPECTION END
7.CHECK EVAP CONTROL SY STEM PRESSURE SENSOR
Refer to EC-850, "
Component Inspection".
OK or NG
OK >> GO TO 8.
NG >> Replace EVAP control system pressure sensor.
8.CHECK INTERMITTENT INCIDENT
Refer to EC-632
.
For wiring diagram, refer to EC-853, "
Wiring Diagram".
>> INSPECTION END
Component InspectionINFOID:0000000005532702
EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected from EVAP canister.
Always replace O-ring with a new one.
2. Install a vacuum pump to EVAP control system pressure sensor.
3. Turn ignition switch ON and check output voltage between ECM terminal 42 (EVAP control system pressure sensor signal) and
ground under the following conditions.
CAUTION:
• Always calibrate the vacuum pump gauge when using it.
• Do not apply below -93.3 kP a (-700 mmHg, -27.56 inHg) or
pressure over 101.3 kPa (760 mmHg, 29.92 inHg).
4. If NG, replace EVAP control system pressure sensor.
Applied vacuum kPa (mmHg, inHg) Voltage (V)
Not applied 1.8 - 4.8
-26.7 (-200, -7.87) 2.1 to 2.5 V lower than above value
PBIB3314E
Revision: January 20102010 Versa
EC-856
< SERVICE INFORMATION >[MR18DE]
DTC P0452 EVAP CONTROL
SYSTEM PRESSURE SENSOR
OK or NG
OK >> GO TO 8.
NG >> Repair short to ground or short to power in harness or connectors.
8.CHECK COMPONENTS
Check the following.
• Refrigerant pressure sensor (Refer to MTC-38
.)
• Crankshaft position sensor (POS) (Refer to EC-798, "
Component Inspection".)
OK or NG
OK >> GO TO 9.
NG >> Replace malfunctioning components.
9.CHECK APP SENSOR
Refer to EC-969, "
Component Inspection".
OK or NG
OK >> GO TO 11.
NG >> GO TO 10.
10.REPLACE ACCELERATOR PEDAL ASSEMBLY
1. Replace accelerator pedal assembly.
2. Perform EC-580, "
Accelerator Pedal Released Position Learning".
3. Perform EC-580, "
Throttle Valve Closed Position Learning".
4. Perform EC-580, "
Idle Air Volume Learning".
>> INSPECTION END
11 .CHECK EVAP CONTROL SYSTEM PRESSURE SE NSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between EVAP control sy stem pressure sensor terminal 1 and ECM terminal
51. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 13.
NG >> GO TO 12.
12.DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors E8, F8
• Harness connectors M69, E7
• Harness connectors B102, M13
• Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
13.CHECK EVAP CONTROL SYSTEM PRESSURE SEN SOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
ECM terminalSensor terminalReference Wiring Diagram
74 Refrigerant pressure sensor terminal 3 EC-1029, "
Wiring Diagram"
75Crankshaft position sensor (POS) terminal 1 EC-794, "Wiring Diagram"
76EVAP control system pressure sensor terminal 3 EC-853, "Wiring Diagram"
102APP sensor terminal 5 EC-972, "Wiring Diagram"
Continuity should exist.
Revision: January 20102010 Versa