Page 1565 of 3745
![NISSAN TIIDA 2010 Service Repair Manual EC-300
< COMPONENT DIAGNOSIS >[HR16DE]
P0448 EVAP CANISTER VENT CONTROL VALVE
P0448 EVAP CANISTER VENT CONTROL VALVE
DescriptionINFOID:0000000005398460
The EVAP canister vent control
valve is located NISSAN TIIDA 2010 Service Repair Manual EC-300
< COMPONENT DIAGNOSIS >[HR16DE]
P0448 EVAP CANISTER VENT CONTROL VALVE
P0448 EVAP CANISTER VENT CONTROL VALVE
DescriptionINFOID:0000000005398460
The EVAP canister vent control
valve is located](/manual-img/5/57397/w960_57397-1564.png)
EC-300
< COMPONENT DIAGNOSIS >[HR16DE]
P0448 EVAP CANISTER VENT CONTROL VALVE
P0448 EVAP CANISTER VENT CONTROL VALVE
DescriptionINFOID:0000000005398460
The EVAP canister vent control
valve is located on the EVAP canis-
ter and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal
the vent is necessary for the on board diagnosis of other evaporative
emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the evapo-
rative emission control system is depressurized and allows “EVAP
Control System” diagnosis.
DTC LogicINFOID:0000000005398461
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT-III
1. Turn ignition switch ON and wait at least 5 seconds.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-III.
4. Start engine and let it idle for at least 1 minute.
5. Repeat next procedures three times.
- Increase the engine speed up to 3,000 to 3,500 rpm and keep it for 2 minutes and 50 seconds to 3 min-
utes.
Never exceed 3 minutes.
- Fully released accelerator pedal and keep engine idle for about 5 seconds.
6. Repeat next procedure 20 times.
- Quickly increase the engine speed up to 4,000 to 4,500 rpm or more and keep it for 25 to 30 seconds.
PBIB1263E
DTC No. Trouble diagnosis name DTC detecting conditionPossible cause
P0448 EVAP canister vent control
valve close EVAP canister vent control valve remains
closed under specified driving conditions. • EVAP canister vent control valve
• EVAP control system pressure sensor
and the circuit
• Blocked rubber tube to EVAP canister
vent control valve
• EVAP canister is saturated with water
Revision: January 20102010 Versa
Page 1566 of 3745
P0448 EVAP CANISTER VENT CONTROL VALVEEC-301
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
- Fully released accelerator pedal and keep engine idle for at least 35 seconds.
7. Check 1st trip DTC.
With GST
Follow the procedure “With CONSULT-III” above.
Is 1st trip DTC detected?
YES >> Go to EC-302, "Diagnosis Procedure".
NO >> INSPECTION END
PBIB0972E
Revision: January 20102010 Versa
Page 1567 of 3745
EC-302
< COMPONENT DIAGNOSIS >[HR16DE]
P0448 EVAP CANISTER VENT CONTROL VALVE
Wiring Diagram
INFOID:0000000005398462
Diagnosis ProcedureINFOID:0000000005398463
1.CHECK RUBBER TUBE
1. Turn ignition switch OFF.
2. Disconnect rubber tube connected to EV AP canister vent control valve.
3. Check the rubber tube for clogging.
AABWA0310GB
Revision: January 20102010 Versa
Page 1568 of 3745
![NISSAN TIIDA 2010 Service Repair Manual P0448 EVAP CANISTER VENT CONTROL VALVEEC-303
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Is the inspection result normal?
YES >> GO TO 2.
NO >> Clean rubber tube using an air blow NISSAN TIIDA 2010 Service Repair Manual P0448 EVAP CANISTER VENT CONTROL VALVEEC-303
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Is the inspection result normal?
YES >> GO TO 2.
NO >> Clean rubber tube using an air blow](/manual-img/5/57397/w960_57397-1567.png)
P0448 EVAP CANISTER VENT CONTROL VALVEEC-303
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Is the inspection result normal?
YES >> GO TO 2.
NO >> Clean rubber tube using an air blower.
2.CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-304, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 3.
NO >> Replace EVAP canister vent control valve.
3.CHECK IF EVAP CANISTER IS SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent c ontrol valve and EVAP control system pressure sensor
attached.
2. Check if water will drain from the EVAP canister.
Does water drain from EVAP canister?
YES >> GO TO 4.
NO >> GO TO 6.
4.CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 1.9 kg (4.2 lb).
Is the inspection result normal?
YES >> GO TO 6.
NO >> GO TO 5.
5.DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehi cle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
6.CHECK EVAP CONTRO L SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check connectors for water.
Is the inspection result normal?
YES >> GO TO 7.
NO >> Replace EVAP control system pressure sensor.
7.CHECK EVAP CONTROL SYS TEM PRESSURE SENSOR
Refer to EC-308, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 8.
NO >> Replace EVAP control system pressure sensor.
8.CHECK INTERMITTENT INCIDENT
Refer to EC-114, "
Diagnosis Procedure".
PBIB1213E
Water should not exist.
Revision: January 20102010 Versa
Page 1569 of 3745
![NISSAN TIIDA 2010 Service Repair Manual EC-304
< COMPONENT DIAGNOSIS >[HR16DE]
P0448 EVAP CANISTER VENT CONTROL VALVE
>> INSPECTION END
Component InspectionINFOID:0000000005398464
1.CHECK EVAP CANISTER VENT CONTROL VALVE-I
1. Turn ignition NISSAN TIIDA 2010 Service Repair Manual EC-304
< COMPONENT DIAGNOSIS >[HR16DE]
P0448 EVAP CANISTER VENT CONTROL VALVE
>> INSPECTION END
Component InspectionINFOID:0000000005398464
1.CHECK EVAP CANISTER VENT CONTROL VALVE-I
1. Turn ignition](/manual-img/5/57397/w960_57397-1568.png)
EC-304
< COMPONENT DIAGNOSIS >[HR16DE]
P0448 EVAP CANISTER VENT CONTROL VALVE
>> INSPECTION END
Component InspectionINFOID:0000000005398464
1.CHECK EVAP CANISTER VENT CONTROL VALVE-I
1. Turn ignition switch OFF.
2. Remove EVAP canister vent control valve from EVAP canister.
3. Check portion (A) of EVAP canister vent control valve for being rusted.
Is it rusted?
YES >> Replace EVAP canister vent control valve.
NO >> GO TO 2.
2.CHECK EVAP CANISTER VENT CONTROL VALVE-II
With CONSULT-III
1. Reconnect harness connectors disconnected.
2. Turn ignition switch ON.
3. Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.
4. Check air passage continuity and operation delay time. Make sure new O-ring is installed properly.
Operation takes less than 1 second.
Without CONSULT-III
Check air passage continuity and operation delay time under the fol-
lowing conditions.
Make sure new O-ring is installed properly.
Operation takes less than 1 second.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Replace EVAP canister vent control valve.
3.CHECK EVAP CANISTER VE NT CONTROL VALVE-III
With CONSULT-III
1. Clean the air passage [portion (A) to (B)] of EVAP canister vent control valve using an air blower.
2. Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.
JMBIA0168ZZ
VENT CONT/V condition Air passage continuity between (A) and (B)
ON Not existed
OFF Existed
Condition Air passage continuity between (A) and (B)
12 V direct current supply between
terminals (1) and (2) Not existed
OFF Existed
JMBIA0169ZZ
Revision: January 20102010 Versa
Page 1570 of 3745
P0448 EVAP CANISTER VENT CONTROL VALVEEC-305
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
3. Check air passage continuity and operation delay time.
Make sure new O-ring is installed properly.
Operation takes less than 1 second.
Without CONSULT-III
1. Clean the air passage [portion (A) to (B)] of EVAP canister vent control valve using an air blower.
2. Check air passage continuity and operation delay time under the
following conditions.
Make sure new O-ring is installed properly.
Operation takes less than 1 second.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace EVAP canister vent control valve.
VENT CONT/V condition Air passage continuity between (A) and (B)
ON Not existed
OFF Existed
Condition Air passage continuity between (A) and (B)
12 V direct current supply between
terminals (1) and (2) Not existed
OFF Existed
JMBIA0169ZZ
Revision: January 20102010 Versa
Page 1581 of 3745
![NISSAN TIIDA 2010 Service Repair Manual EC-316
< COMPONENT DIAGNOSIS >[HR16DE]
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
DescriptionINFOID:0000000005398474
The EVAP control system pressure s
ensor d NISSAN TIIDA 2010 Service Repair Manual EC-316
< COMPONENT DIAGNOSIS >[HR16DE]
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
DescriptionINFOID:0000000005398474
The EVAP control system pressure s
ensor d](/manual-img/5/57397/w960_57397-1580.png)
EC-316
< COMPONENT DIAGNOSIS >[HR16DE]
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
DescriptionINFOID:0000000005398474
The EVAP control system pressure s
ensor detects pressure in the
purge line. The sensor output voltage to the ECM increases as pres-
sure increases.
DTC LogicINFOID:0000000005398475
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “DATA MONITOR” mode with CONSULT-III.
5. Make sure that “FUEL T/TMP SE” indication is more than 0 °C (32° F).
6. Start engine and wait at least 20 seconds.
7. Check 1st trip DTC.
With GST
1. Start engine and warm it up to normal operating temperature.
PBIB3370E
DTC No. Trouble diagnosis name DTC detecting conditionPossible cause
P0453 EVAP control system pres-
sure sensor high input An excessively high voltage from the sensor
is sent to ECM. • Harness or connectors
(EVAP control system pressure sensor
circuit is open or shorted.)
[Crankshaft position sensor (POS) circuit
is shorted.]
(Accelerator pedal circuit is shorted.)
(Refrigerant pressure sensor circuit is
shorted.)
• EVAP control system pressure sensor
• Crankshaft position sensor (POS)
• Accelerator pedal position sensor
• Refrigerant pressure sensor
• EVAP canister vent control valve
• EVAP canister
• Rubber hose from EVAP canister vent control valve to vehicle frame
Revision: January 20102010 Versa
Page 1586 of 3745
![NISSAN TIIDA 2010 Service Repair Manual P0453 EVAP CONTROL SYSTEM PRESSURE SENSOREC-321
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
12.CHECK EVAP CONTROL SYSTEM PRESSURE SENS
OR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1 NISSAN TIIDA 2010 Service Repair Manual P0453 EVAP CONTROL SYSTEM PRESSURE SENSOREC-321
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
12.CHECK EVAP CONTROL SYSTEM PRESSURE SENS
OR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1](/manual-img/5/57397/w960_57397-1585.png)
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOREC-321
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
12.CHECK EVAP CONTROL SYSTEM PRESSURE SENS
OR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Check the continuity between EVAP control syst em pressure sensor harness connector and ECM har-
ness connector.
2. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 14.
NO >> GO TO 13.
13.DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors B102, M13
• Harness connectors M69, E7
• Harness connectors E8, F8
• Harness for open or short between EVAP c ontrol system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
14.CHECK RUBBER TUBE
1. Disconnect rubber tube connected to EV AP canister vent control valve.
2. Check the rubber tube for clogging.
Is the inspection result normal?
YES >> GO TO 15.
NO >> Clean the rubber tube using an air blower, repair or replace rubber tube.
15.CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-298, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 16.
NO >> Replace EVAP canister vent control valve.
16.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to EC-322, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 17.
NO >> Replace EVAP control system pressure sensor.
17.CHECK IF EVAP CANISTER IS SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent c ontrol valve and EVAP control system pressure sensor
attached.
2. Check if water will drain from the EVAP canister.
Does water drain from EVAP canister?
YES >> GO TO 18.
NO >> GO TO 20.
EVAP control system pressure sensor ECM
Continuity
Connector Terminal Connector Terminal
B104 2F1142Existed
PBIB1213E
Revision: January 20102010 Versa