Aston Martin V12 Family
2009 MY V12 Family EOBDincl. V12 Vantage
Aston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ation
Engine coolant temp 110 deg C (> 230 deg F)Continuous time with
engine off prior to start > 360 min
Time with high sensor
signal > 100 sec
ECT at start differs from
IAT at start >28 deg C
(> 50 deg F)
Catalyst, Misfire, Fuel
System or HO2S Monitors
Sensor signal voltage > 4.9 volts (-41.25degF)
Fault filter routine > 5.0 sec
Sensor signal voltage < 0.13 volts (302.75degF)
Fault filter routine > 5.0 sec Engine off soak time >360 minutes
IAT sensor OK
(P0112/0113)
Rationality check, Engine-Off
timer inoperative Soak timer value at startup < 0.5 * 60 sec (Timer
indicates that short
soak has occurred)Engine coolant
temperature at previous
key-off >90degC (indicates hot
engine)
Engine coolant
temperature at previous
key-off - coolant at start > 55 deg C
(> 100 deg F)
(Degree of cooling
indicates that a long soak
has occurred)
Vehicle ID block not
programmed P1639 VID block not programmed
with tire/axle ratio Time with error present > 0 sec
NoneNoneContinuous Footnote a) Footnote c)
VID Block checksum P0602 VID block checksum test failedTime with error present > 0 sec
NoneNoneContinuous
KAM Failed / reset P0603 Keep Alive Memory check failed / memory was resetTime with error present > 0 sec
NoneNoneContinuous Footnote a) Footnote c)
RAM memory failed P0604 Random Access Memory test has failed.Time with error present > 0 sec
NoneNoneContinuous Footnote a) Footnote c)
ROM checksum test
failed P0605 Read Only Memory test failed Time with error present > 0 sec
NoneNoneContinuous Footnote a) Footnote c)
CPU Fault detected P0607 General fault with the CPU has been detectedTime with error present > 0 sec
NoneNoneContinuous
Keep Alive Memory
Power Input P1633 KAM power input voltage too
low/open circuit Time with error present > 20 sec
NoneNoneContinuous Footnote k) Footnote i)
Loss of
Communication with
TCM U0101 Monitors CAN bus between
ECM and TCM Time with fault present > 1.36 seconds
Continuous
Sensor input < 0.21 volts (131degC)
or
> 4.93 volts(-45degC)
Time with sensor input out
of range > 3.0 sec
Sensor input < 0.21 volts (131degC)
Time with sensor input out
of range > 3.0 sec
Sensor input > 4.93 volts
(-45degC)
Time with sensor input out
of range > 3.0 sec 11< Voltage <18 Continuous Footnote a) Footnote c)
MATF Sensor Input P0097 (High) Range check Battery Voltage
P0098 (Low) Range check
P009A Rationality Check - error between manifold temperature
and IAT after long soak Manifold temperature -
IAT
>< +/- 26degC
(80degF)
ECT Sensor Input P0116 Rationality check (Stuck high)
Once per driving
cycleFootnote a) Footnote c)
Engine-Off (Soak)
Timer Rationality
Test P0606
Once per driving
cycleFootnote a) Footnote b)
Fuel Temperature
Sensor Input P0180
P0182 (Low)
P0183 (High)Circuit Malfunction - range
check
Circuit Malfunction - range
check
None
N/A Continuous Footnote a) Footnote c)
11
Aston Martin V12 Family
2009 MY V12 Family EOBDincl. V12 Vantage
Aston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ation
Sensor input stuck
midrange 123 +/- 34 kPa
(17.9 +/- 5.0 psig)
Large control error 34 kPa (> 5.0 psig)
Sensor value not moving 5.5 kPa/second (< 0.8 psig/second)
Time with sensor input out
of range > 8.0 sec
(Demand - sensed) error
too large > 172 kPa
(25.0 psig)Demand pressure within
limits < 448 kPa or > 241 kPa
(< 65.0 psig or > 35.0
psig)
Time with sensor input out
of range > 8.0 sec
Fuel level above minimum
level > 0.15 * 100 %
Sensor input < 0.05 volts
(<0kPa)
Time with sensor input out
of range > 8.0 sec
Sensor input > 4.88 volts
(>517kPa)
Time with sensor input out
of range > 8.0 sec
P1233 Fuel pump driver module disabled or off line Time with failure > 3.0 seconds
P1235 Fuel pump control out of range Time with failure > 3.0 seconds
P0201 Circuit continuity check, open or shorted Smart power driver status 1 = malfunction Battery voltage
> 11.0 volts
P0202 Time with circuit
malfunction > 3.5 sec
Engine coolant temp < 116 deg C (< 240 deg F)
P0203 Intake air temp66 deg C (< 150 deg F)
P0204
P0205
P0206
P0320 Engine rpm (Used to
determine crank mode) > FN384A rpm
(See Function)None
Intermittent/Noisy CKP signal
check Number of CKP edges
incorrect, missing tooth in None
Increment fault counter by
25 on each event. Set
P0322 Engine speed input circuit no signal Compares engine rpm on
one bank to engine rpm o
nNone
Increment fault counter by
4 on each event. Set
Camshaft Position
Input P0340 Rationality check
Ratio of PIP events to CID
events n to 1 (To pass test) None
N/A Footnote c)
Footnote c)
Fuel Rail Pressure
Input P0190
P0191
P0192 (Low)
P0193 (High)Range check
Range/Performance check
Fuel Pump Continuous
Circuit malfunction N/A
Continuous Footnote a) Footnote c)
None
None
N/A Footnote a)
Fuel Injectors Footnote c)
Ignition System- CKP
Circuit Malfunction Continuous Footnote a) Footnote c)
Continuous Footnote a)
12
Aston Martin V12 Family
2009 MY V12 Family EOBDincl. V12 Vantage
Aston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ation
P0351(Coil A) Ratio of PIP events to
spark events seen 1 to 1 (To pass test) Battery voltage
> 11.0 volts or < 18.0 volts Continuous Footnote a) Footnote c)
P0352(Coil B) PCM able to determine
coil Yes
P0353(Coil C)
P0354(Coil D)
P0355(Coil E)
P0356(Coil F) Functional check -
overspeed error Difference between actual
and desired rpm> -200 rpm
Engine coolant temp -7 deg C (> 20 deg F)
Time since engine start > 100 sec
Time with solenoid at limit > 15 sec Fuel controlClosed loop
Idle state At idle
Difference between actual
and desired rpm > 100 rpm
Engine coolant temp -7 deg C (> 20 deg F)
Closed loop MAF
correction > 4.5 g/sec
(> 0.6 lbs/min)Time since engine start > 100 sec
Time with solenoid at limit > 10 sec Fuel controlClosed loop
Idle state At idle
Vehicle Speed
Sensor P0500 Functional check - operational Evaluates CAN source VS > 3 mph
> 4 secondsVehicle moving
Commanded dutycycle on
or full-off >=0.135 * 100 % or =
0%None
N/A Continuous Footnote a) Footnote e)
Signal circuit voltage Refer to Appendix for threshold calculation
Time with circuit
malfunction > 5 sec
P0460 (Range
Check) Sensor input
<= 7 or >= 254 A/D
counts w/in a range of
256 A/D counts
P0462 (Low) < 7 A/D counts
P0463 (High) > 254 A/D counts
Time with sensor out of
range > 30 sec N/A
Continuous Footnote a) Footnote j)
Fuel Level Input Out
Of Range Sensor range check
None
Vapor Management
Valve Circuit
Malfunction
P0443 Circuit continuity test, open or
shorted Footnote a) Footnote c)
IAC Solenoid
Underspeed Error P0506 Functional check -
underspeed error Continuous
IAC Solenoid
Overspeed Error
P0507
Continuous Footnote a) Footnote c)
Ignition System-
Ignition Coil Primary
Circuit Malfunction
Rationality check
13
Aston Martin V12 Family
2009 MY V12 Family EOBDincl. V12 Vantage
Aston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ationTPPC chip failure in
PCM P0606 TPPC chip to CPU
communication fault Number of attempts > 1
Continuous Footnote a) Footnote c)
Engine rpm > 1000 rpmEngine coolant temp > 15 deg C (> 60 deg F) Continuous Footnote a) Footnote c)
Sensor signal voltage < 0.73 volts or > 3.0 volts
Engine load > 0.7 * 100% or < 0.2
* 100%
Time with sensor out of
range > 5.0 sec
Time with low throttle
voltage at TPPC or PCM >= 0.254 seconds
Sensor signal voltage < 0.2 volts
Time with high throttle
voltage at TPPC or PCM >= 0.254 seconds
Sensor signal voltage > 4.87 volts
Time with low throttle
voltage at TPPC or PCM >= 0.254 seconds
Sensor signal voltage < 0.08 volts
Time with high throttle
voltage at TPPC or PCM >= 0.254 seconds
Sensor signal voltage > 4.80 volts
Time with correlation
failure from the TPPC or
PCM or Equizzer >= 240 sec
Magnitude of the
difference of the relative
readings of the sensor
signal voltage > 0.25 volts
(10.25degrees)
P2104 ETC FMEM – forced idle Two or three pedal sensors failed, throttle
plate stuck>= 100 to 400 msec None
N/AContinuous Footnote a) Footnote c)
P2105 ETC FMEM – forced engine shutdown Equizzer detected fault >= 16 to 960 msec None
N/AContinuous Footnote a) Footnote c)
P2106 ETC FMEM – pedal-follower mode Sensor fault: MAF, one
TP, CKP, TSS, OSS,
stuck throttle, throttle
actuator circuit fault>= 16 to 960 msec None
N/AContinuous Footnote a) Footnote c)
P2110 ETC FMEM – default throttle angle Two TPs failed; TPPC
detected fault>= 600 to 800 msec None
N/AContinuous Footnote a) Footnote c)
Throttle Actuator
Control SystemElectronic Throttle ControlTP Sensor A/B
Correlation
P2135 Rationality check None N/A Continuous Footnote a) Footnote c) Footnote c)
TP Sensor 'B' Input
Out Of Range P0222 (Low)
P0223 (High)Range check None N/A Continuous Footnote a) Footnote c) None N/A Continuous Footnote a)
TP Sensor 'A' Input
Out Of Range P0122 (Low)
P0123 (High)Range check
TP Sensor
Inconsistent With
MAF Sensor
P0068 Rationality check vs. MAF
input
15
Aston Martin V12 Family
2009 MY V12 Family EOBDincl. V12 Vantage
Aston Martin/Ford Confidential
Signal circuit voltage threshold calculation for DTC P0443
At 98% DC: [(42 x Battery voltage) - 150] x 5.0/1024 volts
At 0% DC: [(32 x Battery voltage) - 200] x 5.0/1024 volts
Misfire Monitor Time Delay Since Engine Start Up = 0 seconds + FNMISACT value
FNMISPCT_97
Load RPM 500 850 1000 1500 1750 2000 3000 5000 6000 7000
0.1
0.16 0.16 0.16 0.16 0.16 0.16 0.11 0.07 0.07 0.07
0.15
0.16 0.16 0.16 0.16 0.16 0.16 0.11 0.06 0.06 0.06
0.2
0.16 0.16 0.16 0.16 0.16 0.16 0.11 0.06 0.06 0.06
0.25
0.16 0.16 0.16 0.16 0.16 0.13 0.08 0.07 0.07 0.06
0.3
0.16 0.16 0.16 0.16 0.15 0.10 0.07 0.07 0.08 0.08
0.35
0.16 0.16 0.16 0.16 0.11 0.09 0.07 0.08 0.08 0.07
0.4
0.15 0.15 0.15 0.11 0.07 0.07 0.08 0.07 0.06 0.05
1
0.10 0.10 0.10 0.09 0.08 0.07 0.07 0.06 0.05 0.05
FNMISACT
ACT
( C
)
-160 -40 -29 82 88 123
output_axis [s]180 180 0 0 180 180
FNMISOK_97
Load RPM 500 850 1000 1500 1750 2000 3000 7000 6000 7000 0.05
0000000000
0.1
0.72 0.72 0.72 0.8 0.8 0.8 0.2 0 0 0
0.15
1111110.7000
0.2
11111110.300
0.25
11111110.80.30
0.3
111111110.80.4
0.35
1111111110.9
0.4
1111111111
17
System
Component
P Codes (AML)
Malfunction Strategy Description
Malfunction Criteria
(Fault)
Fault condition
(Internal labels)
Threshold Value
(Fault condition)
Entry conditions
Entry conditions values
Filter Time to log DTC (AML)
EMS controlled MIL Illumination
(AML)
CAN LinkEngine P0725Engine speed signal
Engine Speed signal QF ≠ 3 No CAN BUS error.
No CAN level error and
No EMS timeout.600mS
1 DTC
CAN Link CAN level P0614Incorrect configuration ID received CANid does not match that stored in the TCM Engine not in crank.
No CAN BUS error
Ignition on & Timer after ignition passed.
Battery Voltage > threshold7v250mS
1 DTC
CAN Link CAN bus off P1796Monitors the CAN for Bus or RAM faults.
TCM CAN driver detects CAN bus fault. Bit, stuff, CRC or form error,
(CAN-wiring or CAN-module defective, EMC
radiation.) Battery voltage > Threshold
7v100mS1 DTC
Sensor Temperature Sensor P0711 ATF temperature sensor short circuit ATF sensor faulty - Sensor input signals (Vcgt_plus
and Vcgt_minus) out of acceptable range utmsm2_Gt
utmsm2_Gt
and
utmsm2_Gt =2.3v
utmsm1_Gt =2.7v 1.5s
2 DTC
Sensor Temperature Sensor P0711ATF Sensor - stuck value Stuck Temperature value - ATF temperature is out
of an acceptable range of tolerance when
compared to the TCM chip temperature sensor
value.
Range of tolerance is depending on the heating up
velocity of transmission . [
Fast heating = wide range of tolerance :
Chip sensor temp +/- cgt_tolwt <> ATF
temperature
OR
Slow heating = narrow range of tolerance :
Chip sensor temp +/- cgt_toleng <> ATF
temperature.]
AND
Temperature cgtf_Neu out of allowed range of
tolerance for > zgts_CgtPlausiErr * 100ms cgt_tolwt = 40degC
cgt_toleng = 25degC
AML: zgts_CgtPlausiErr= 6000 ( =
10min)
Jag+LR: zgts_CgtPlausiErr= 9000 ( =
15min)Chip sensor OK
Engine speed > threshold
Turbine speed > threshold
450rpm
450rpm1.5s
2 DTC
Sensor Temperature Sensor P0713ATF Sensor short to battery ATF sensor faulty - Sensor input signals (Vcgt_plus
and Vcgt_minus) out of acceptable range vcgt_plus > utmso_Gt
and
vcgt_minus > utmsu_Gtutmso_Gt = 4.5v
utmsu_Gt =0.5v
1.5s
2 DTC
Sensor Temperature Sensor P0712ATF Sensor short to GND ATF sensor faulty - Sensor input signals (Vcgt_plus
and Vcgt_minus) out of acceptable range vcgt_plus < utmso_Gt
and
vcgt_minus < utmsu_Gtutmso_Gt = 4.5v
utmsu_Gt =0.5v
1.5s
2 DTC
Sensor Temperature Sensor P0714ATF sensor open cct (circuit break) ATF sensor faulty - Sensor input signals (Vcgt_plus
and Vcgt_minus) out of acceptable range vcgt_plus > utmso_Gt
and
vcgt_minus < utmsu_Gtutmso_Gt = 4.5v
utmsu_Gt =0.5v
1.5s
2 DTC
Sensor Temperature Sensor P0713 ATF temperature sensor value jump
or
ATF value not warming up quickly
enough Unacceptable temperature jump (lOld value - new
value <> threshold) within a period of 100ms
or
ATF temperature (cgt_neu) not warming up quickly
enough within a specified time period
|cgt_Neu - cgta1_CUew| > cgtd1_Cuew
or
(cgt_Neu(t=tgtd_CUew) - cgt_Neu(t=0) ) <
cgtd2_Cuewcgtd1_Cuew = 20DegC
cgtd2_Cuew = 4DegC
tgtd_CUEW = 240s
Output speed > Threshold
Engine speed > Threshold
No Output speed & Engine speed error
Temperature cgt_Neu < Threshold at t=0Jag +
AML / LR
800 / 11000rpm
400 / 11000rpm
20DegC1.5s
2 DTC
TCM Internal Impossible substitute functions (monitoring contradictory
substitute functions) P0701
Two Priority 2 faults present at the same
time (Currently not possible) 20ms
2 DTC
TCM Internal Impossible substitute functions (monitoring contradictory
substitute functions) P0701
OSS fault and wheel speed faults present
concurrently (Priority 3) Wheel speed and output speed sensor faults
present concurrently. 20ms
2 DTC
TCM Internal Impossible substitute functions (monitoring contradictory
substitute functions) P0701
Bosch solenoid current monitorin
g fault 20ms 2 DTC
TCM Internal EEPROM Flash emulation P062FEEPROM emulation lifetime exceeded Communication disturbed, lifetime exceeded EEError !=0 =1
400000 Write/Erase-cycles possible. At
temperatures over 135°C no EEProm
update is made.always active
no0mS1 DTC
TCM Internal FLASH checksum P1603Checksum incorrect Calculated checksum does not match stored
checksum 0mS
2 DTC
CAN Link Engine P1719Engine Torque signal inaccurate
Engine torque signal QF 0 = 3 fcn_MmmErr
=1No CAN BUS error.
No CAN level error
and No EMS timeout. 600ms
2 DTC
CAN Link Engine Speed P1920Engine speed too high Engine Speed > Engine speed threshold> for a time
threshold n_mot > NS_MOTUEB
&
Timer_nmotueb > T_FNMOTUEBNS_MOTUEB = 7100rpm
T_FNMOTUEB=2550mS T_FNMOTUEB=2550mS 2 DTC
Speed Sensors Turbine speed sensor P0715Turbine speed sensor s/c to battery
supply Turbine speed sensor s/c to battery supply sgt_DiNtu = 2 (short circuit to plus)
2 (Status of turbine speed sensor signal. Sensor supply voltage OK0600mS2 DTC
Speed Sensors Turbine speed sensor P0717Turbine speed sensor s/c to gnd or O/C Turbine speed sensor s/c to gnd or O/C sgt_DiNtu = 0 (short to gnd or OC)0 (Status of turbine speed sensor signal. Sensor supply voltage OK 0600mS2 DTC
Speed Sensors Turbine speed sensor P0716Turbine Speed Value too high Value too high NTU >= NTUmaxntumax = 8000rpmSensor supply voltage OK
No electrical error 0
600mS2 DTC
Speed Sensors Turbine speed sensor P0716Turbine Speed Value too low Value too low NTU < ntu_Minntu_min = 20 rpmSensor supply voltage OK
No electrical error
engine speed NMO is higher than a
threshold:
status of NMO-signal is alright
output speed NAB is higher than a
threshold:
status of NAB-signal is alright or substitute
fltfl fb Ei t t
nmos_TuUew = 600rpm
nabs_TuUew = 250rpm 600mS
2 DTC
8ASXV05.9VH1 Aston Martin
Auto Gearbox Summary Jan 2008
System
Component
P Codes (AML)
Malfunction Strategy Description
Malfunction Criteria
(Fault)
Fault condition
(Internal labels)
Threshold Value
(Fault condition)
Entry conditions
Entry conditions values
Filter Time to log DTC (AML)
EMS controlled MIL Illumination
(AML)
y volts Vs temp - Appendix A,
Ref 2 Test condition is always fulfilled. 0ms 1 DTC
System Voltage Battery Voltage P1793 Power Supply too low Battery voltage ugt_Batt < ugtu_Batt or
ugtu_BattDef< 7V
< 7VEngine speed >
Turbine speed >
Transmission position
Mechanical limp home active1400rpm
1400rpm
Park or Neutral
False30ms
2 DTC
Mechatronic Unit Shift Solenoid P0771Solenoid / Valve stuck Stuck off Solenoid 1 or 2 timer_MV12mechdef <=
KL_TUEBCGMV12MECHDEF and
(GET_P_SENSOR = 0 or GET_P_SENSOR = 2) 500mspumpendruck_vorhanden
Park sensor = P (GET_P_SENSOR)0->1
0ms2 DTC
System Voltage Pressure regulator and solenoid power supply P0657Pressure regulator supply too low (power
supply cannot be switched on) Sensor voltage too low because power supply
cannot be switched ON. FET off
= trueBattery Voltage > 7v30mS2 DTC
System Voltage Pressure regulator and solenoid power supply P0659Voltage applied without activation of the
controlling FET FET cannot be switched on (Short circuit to battery) Vbatt > udrmv_batt
7v 30mS2 DTC
System Voltage Pressure regulator and solenoid power supply P0658Sensor supply voltage < threshold
or
Voltage drop across FET is too big PR supply voltage too low
u
gt_drmv < udrmv_ksm
or
lugt_batt-ugt_drmvl > ugtd_fet 0.5v
or
1vBattery Voltage > udrmv_batt
7v30mS2 DTC
System Voltage Pressure regulator and solenoid power supply P0657Voltage too low due to reset. PR supply voltage too low ugt_drmv < Ugtu_bat
fgt_Dreset = Ugtu_bat = 2D map (V vs C) Appendix A,
ref 3
TrueFET control OK
Battery Voltage > udrmv_batt
1
7v30mS
2 DTC
TCM Internal TCM Watchdog P0613Error counter does not reach required
value during initialisation Error counter does not reach required value sdi_Ufet=1 or
sdi_Ufet=4 or
sdi_Ufet=5 or
sdi_Ufet=8 Battery Voltage > ugt_UfetIni
TCU in initialisation phase
7v
0ms2 DTC
TCM Internal TCM Watchdog P0613Error counter exceeds limit Error counter exceeds limit Zs_errorCountForUC > 4.4Cyclic (operation): Debug-mode not active 0
0ms2 DTC
TCM Internal TCM Watchdog P0613FET cannot be switched off FET cannot be switched off
(DReset line is high) DReset line is high
(fgtr_Dreset = False)FALSE
Battery Voltage > ugt_UfetIni
TCU in initialisation phase7v
0ms2 DTC
TCM Internal TCM Watchdog P0613FET cannot be switched On FET cannot be switched On
(DReset line is low) Reset Line is low.
(Fgtr_Dreset = True)TRUE
Battery Voltage > ugt_UfetIni
TCU in initialisation phase7v
0ms2 DTC
TCM Internal TCM Watchdog P0613Safety circuit reset line between CG115
and CG120 is active. Safety circuit reset line between CG115 and CG120
is active. Reset line = high
(fgtr_Dreset!=0)!=0
Cyclic (operation): Debug-mode not active 0
0ms2 DTC
TCM Internal TCM Watchdog P0613Watchdog function taking too long. Watchdog function taking too long. tgts_UewFetGes > Threshold300msBattery Voltage > ugt_UfetIni
TCU in initialisation phase7v
0ms2 DTC
TCM Internal TCM Watchdog P0613FET cannot be switched off at
ErrorCountForUC >= 5 FET cannot be switched off at
ErrorCountForUC >= 5 FET cannot be switched off at
ErrorCountForUC >= 55
Battery Voltage > ugt_UfetIni
TCU in initialisation phase7v
0ms2 DTC
TCM Internal TCM Watchdog P0613FET cannot be switched on at
Zsk_ErrorCountForUC<=4 FET cannot be switched on at
Zsk_ErrorCountForUC<=4 FET cannot be switched on at
Zsk_ErrorCountForUC<=44
Battery Voltage > ugt_UfetIni
TCU in initialisation phase7v
0ms2 DTC
TCM Internal TCM Watchdog P0613CPU watchdog error counter threshold
exceeded. (WD to CPU) CPU watchdog error counter threshold exceeded.
(Zsk_ErrorCountForWD>3) CPU watchdog error counter threshold
exceeded.
(Zsk_ErrorCountForWD>3)3
Cyclic (operation): Debug-mode not active 0
0ms2 DTC
Torque Converter Torque Converter P0741Torque converter slip too high Torque converter slip > threshold. KL_NDSKPLDEFEKT25rpmSlip too high timer expired
Closed or Closed Loop Control 10.0s
2 DTC
Pressure Regulators PR1 P0973Pressure regulator 1 short circuit to
ground or o/c. current > threshold
or
current = 0 idr_Mess1 > idr1 + idrs_high
or
idr1=0mAidrs_high = 2D map (Current vs Temp)
0mA
Solenoid Supply > threshold
Engine running
0% or 100% measured current PWMudrso_prf = 2D map (V vs Temp) See
App A, Ref 1
30mS
2 DTC
Pressure Regulators PR1 P0972Pressure regulator 1 current too high current > threshold idr_Mess1 > idr1 + idrs_highidrs_high = 2D map (Current vs Temp) Solenoid Supply > threshold
Measured control PWM not = 0 or 100%udrso_prf = 2D map (V vs Temp) See
App A, Ref 130mS
2 DTC
Pressure Regulators PR1 P0974Pressure regulator 1 short to battery current < threshold idr_Mess1 < idr1 + idrs_lowidrs_low = 2D map (Current vs Temp) Solenoid Supply > threshold
Engine not running
Measured control signal PWM = 0%udrso_prf = 2D map (V vs Temp) See
App A, Ref 1
30mS
2 DTC
Pressure Regulators PR2 P0976Pressure regulator 2 short circuit to
ground or o/c. current > threshold
or
current = 0 idr_Mess2 > idr2 + idrs_high
or
idr1=0mAidrs_high = 2D map (Current vs Temp)
0mA
Solenoid Supply > threshold
Engine running
0% or 100% measured current PWMudrso_prf = 2D map (V vs Temp) See
App A, Ref 1
50mS
2 DTC
Pressure Regulators PR2 P0975Pressure regulator 2 current too low current < threshold idr_Mess2 < idr2 + idrs_lowidrs_low = 2D map (Current vs Temp) Solenoid Supply > threshold
Meassured control PWM not = 0 or 100%udrso_prf = 2D map (V vs Temp) See
App A, Ref 150mS
2 DTC
Pressure Regulators PR2 P0977Pressure regulator 2 short to battery current < threshold idr_Mess2 < idr2 + idrs_lowidrs_low = 2D map (Current vs Temp) Solenoid Supply > threshold
Engine not running
Measured control signal PWM = 0%udrso_prf = 2D map (V vs Temp) See
App A, Ref 1
50mS
2 DTC
Pressure Regulators PR3 P0979Pressure regulator 3 short circuit to
ground or o/c. current > threshold
or
current = 0 idr_Mess3 > idr3 + idrs_high
or
idr1=0mAidrs_high = 2D map (Current vs Temp)
0mA
Solenoid Supply > threshold
Engine running
0% or 100% measured current PWMudrso_prf = 2D map (V vs Temp) See
App A, Ref 1
50mS
2 DTC
Pressure Regulators PR3 P0978Pressure regulator 3 current too high current > threshold idr_Mess3 > idr3 + idrs_highidrs_high = 2D map (Current vs Temp) Solenoid Supply > threshold
Measured control PWM not = 0 or 100%udrso_prf = 2D map (V vs Temp) See
App A, Ref 150mS
2 DTC
Pressure Regulators PR3 P0980Pressure regulator 3 short to battery current < threshold idr_Mess3 < idr3 + idrs_lowidrs_low = 2D map (Current vs Temp) Solenoid Supply > threshold
Engine not running
Measured control signal PWM = 0%udrso_prf = 2D map (V vs Temp) See
App A, Ref 1
50mS
2 DTC
Pressure Regulators PR4 P0982Pressure regulator 4 short circuit to
ground or o/c. current > threshold
or
current = 0 idr_Mess4 > idr4 + idrs_high
or
idr1=0mAidrs_high = 2D map (Current vs Temp)
0mA
Solenoid Supply > threshold
Engine running
0% or 100% measured current PWMudrso_prf = 2D map (V vs Temp) See
App A, Ref 1
50mS
2 DTC
8ASXV05.9VH1 Aston Martin
Auto Gearbox Summary Jan 2008
System
Component
P Codes (AML)
Malfunction Strategy Description
Malfunction Criteria
(Fault)
Fault condition
(Internal labels)
Threshold Value
(Fault condition)
Entry conditions
Entry conditions values
Filter Time to log DTC (AML)
EMS controlled MIL Illumination
(AML)
(V vs Temp
)App A,
Ref 1
1
30mS 50mS
2 DTC
Mechatronic Unit Shift Solenoid P0985SV1 S/C Gnd Target max.7.6% Hardware register fault or
umv1_RLo <7.6%
FET turned on
lowside drivers unlockedTrue
True20mS
2 DTC
Mechatronic Unit Shift Solenoid P0986SV1 S/C Battery PWM target max. 92.4% umv1_Rhi>92.4%FET turned on
lowside drivers unlocked True
True20mS
2 DTC
Mechatronic Unit Shift Solenoid P0770SV1 O/C PWM target max 7.6 umv1_Rlo<7.6%FET turned on
lowside drivers unlocked True
True20mS
2 DTC
Mechatronic Unit Shift Solenoid P0998SV2 S/C Gnd Target max.7.6% Hardware register fault or
umv2_RLo <7.6%
FET turned on
lowside drivers unlockedTrue
True20mS
2 DTC
Mechatronic Unit Shift Solenoid P0998SV2 O/C or S/C Gnd PWM target max. 92.4% Hardware register fault=100%FET turned on
lowside drivers unlocked True
True20mS
2 DTC
Mechatronic Unit Shift Solenoid P0999SV2 S/C Battery PWM target max. 92.4% umv2_Rhi>92.4%FET turned on
lowside drivers unlocked True
True20mS
2 DTC
Mechatronic Unit Shift Solenoid P2706SV2 O/C PWM target max 7.6 umv2_Rlo<7.6%FET turned on
lowside drivers unlocked True
True20mS
2 DTC
Mechatronic Unit Park Solenoid P2814SV3 S/C Gnd Target max.7.6% Hardware register fault or
umv3_RLo <7.6%
FET turned on
lowside drivers unlockedTrue
True100mS
2 DTC
Mechatronic Unit Park Solenoid P2814SV3 O/C or S/C Gnd PWM target max. 92.4% Hardware register fault=100%FET turned on
lowside drivers unlocked True
True100mS
2 DTC
Gear monitoring 1st Gear ratio P07311st Gear slip too high 1st gear slip > threshold nd_syn > KL_NDUWG1Outputspeed 0.0 1000 2000
Ndsyn> 400 400 640 ATF temp > threshold
output speed > threshold
Engine Speed > threshold
Turbine Speed > threshold0DegC
0rpm
550rpm
416rpm3 Symptoms
2 DTC
Gear monitoring 2nd gear ratio P07322nd Gear slip too high 2nd gear slip > threshold nd_syn > KL_NDUWG2Outputspeed 0.0 1000 3300
Ndsyn> 400 400 640 ATF temp > threshold
output speed > threshold
Engine Speed > threshold
Turbine Speed > threshold0DegC
0rpm
550rpm
416rpm3 Symptoms
2 DTC
Gear monitoring 3rd gear ratio P07333rd Gear slip too high 3rd gear slip > threshold nd_syn > KL_NDUWG3Output speed 0.0 1000 5000
Ndsyn> 400 400 640 ATF temp > threshold
output speed > threshold
Engine Speed > threshold
Turbine Speed > threshold0DegC
0rpm
550rpm
416rpm3 Symptoms
2 DTC
Gear monitoring 4th gear ratio P07344th Gear slip too high 4th gear slip > threshold nd_syn > KL_NDUWG4Output speed 0.0 1000 6500
Ndsyn> 400 400 640 ATF temp > threshold
output speed > threshold
Engine Speed > threshold
Turbine Speed > threshold0DegC
0rpm
550rpm
416rpm3 Symptoms
2 DTC
Gear monitoring 5th gear ratio P07355th Gear slip too high 5th gear slip > threshold nd_syn > KL_NDUWG5Output speed 0.0 1000 8160
Ndsyn> 400 400 640 ATF temp > threshold
output speed > threshold
Engine Speed > threshold
Turbine Speed > threshold0DegC
0rpm
550rpm
416rpm3 Symptoms
2 DTC
Gear monitoring 6th gear ratio P07296th Gear slip too high 6th gear slip > threshold nd_syn > KL_NDUWG6Output speed 0.0 1000 8160
Ndsyn> 400 400 640 ATF temp > threshold
output speed > threshold
Engine Speed > threshold
Turbine Speed > threshold0DegC
0rpm
550rpm
416rpm3 Symptoms
2 DTC
Shift Monitoring Gear load 1-2 shift P0781Gear load error during 1-2 shift. Clutch C
does not close. (input speed - output speed x ratio) > threshold ND_TSUEA12Z
>400rpmoutputspeed > threshold
transmission oil temperature > threshold
engine speed
range position 256rpm
10DegC
1200rpm
no P, R, N5 Symptoms
2 DTC
Shift Monitoring Gear load 1-2 shift P0781Gear load error during 1-2 shift. Clutch D
does not open.
(input speed - output speed x ratio
) (t) - (input speed
- output speed x ratio) (0) < threshold ND_TUNSUEB
<30rpmoutput speed > threshold
transmission oil temperature > threshold
engine speed
range position 256rpm
10DegC
1200rpm
no P, R, N5 Symptoms
2 DTC
Shift Monitoring Gear load 2-3 shift P0782Gear load error during 2-3 shift. Clutch C
does not close. (input speed - output speed x ratio) > threshold ND_TSUEA23Z
>300rpmoutput speed > threshold
transmission oil temperature > threshold
engine speed
range position 256rpm
10DegC
1200rpm
no P, R, N5 Symptoms
2 DTC
8ASXV05.9VH1 Aston Martin
Auto Gearbox Summary Jan 2008