Page 36 of 99

62B-36
MR-413-X44-62B000$460_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
MAIN SCREEN
NOTESOnly carry out this conformity check after a full check using the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped with ignition on (12 V APC), AIR
CONDITIONING OFF (air conditioning compressor not activated).
Note:
This page lists the statuses and parameters provided by the climate control computer
but which are not associated with the three sub-functions given in the conformity
check (PASSENGER COMPARTMENT VENTILATION, COLD LOOP and HEATING
sub-functions).
FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
Electrical suppliesPR092:Battery voltage10.5 V < X <14.4 VIn the event of a fault, see the
interpretation of this
parameter.
ET083:+ 12 V after
ignition present ABSENT: Ignition off.
PRESENT: Ignition on.In the event of a fault, refer to the
interpretation of this status.
ET002:+ 12 V side
lightsABSENT: Side lights off.
PRESENT: Side lights
on.In the event of a fault, refer to the
interpretation of this status.
PR122:Night lighting
level15 % = minimum
lighting level
99 % = maximum
lighting level
(side lights
off: 102 %)In the event of a fault, refer to the
interpretation of this status.
Note:
This parameter is displayed via
the climate control computer but
is generated by the instrument
panel.
Page 37 of 99

62B-37
MR-413-X44-62B000$460_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning
compressor activated).
Note:
–Read the parameters when the vehicle is cold (in the morning) to check the
conformity of the temperature parameters (without thermometer). The two
temperatures should be practically the same (as should the coolant temperature
given by the injection system).
–The invalid values given in this check correspond to the value sent by the diagnostic
tool (substitute value) when the sensor in question is faulty. A sensor fault can be
detected when these invalid values are displayed (this is an important point for
sensors on which fault finding cannot be performed, e.g. exterior temperature
sensor).
FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
Passenger
compartment
blowerPR019: Passenger
compartment
fan PWM settingSpeed 0 = 0 %
Speed 8 = 100 %
Note:
The PWM signal is a
modulated control
voltage used to control
the air conditioning
blower power module.If there is a fault or for more
information (to find the
intermediate speed
percentages), refer to the
interpretation of this
parameter.
Note:
If the parameter varies correctly,
but the passenger compartment
blower unit is not working: refer to
fault finding chart no. 5.
ET141: Passenger
compartment
blowerRUNNING
or
STOPPED
After a user request.In the event of a fault, refer to the
interpretation of this status.
Air flapsPR012: Mixing flap
positionFrom 0 % (“Maximum
cold” position: 15 ˚C)
to 100 % (“Maximum
hot” position: 27 ˚C).In the event of a fault, see the
interpretation of this
parameter.
ET062: Recirculation
flap positionOPEN if the flap is in the
external air position.
CLOSED if the flap is in
the recirculation
position.In the event of a fault, refer to the
interpretation of this status.
PR011: Distribution flap
positionFrom 0 % (Air vent
position)
to 100 % (De-icing
position).In the event of a fault, refer to the
interpretation of this status.
Page 38 of 99
62B-38
MR-413-X44-62B000$460_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION (CONTINUED)
NOTESOnly carry out this conformity check after a full check using the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine running, (12 V APC) AIR CONDITIONING ON
(air conditioning compressor activated).
FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
TemperaturesPR001:Interior
temperatureX = interior
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)In the event of a fault, see the
interpretation of this
parameter.
PR002:External
temperatureX = exterior
temperature ± 5 ˚C
(invalid value: 215 ˚C)In the event of a fault, see the
interpretation of this
parameter.
Note:
This parameter is displayed via
the climate control computer but
is generated by the UCH.
Page 39 of 99

62B-39
MR-413-X44-62B000$460_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
COLD LOOP SUB-FUNCTION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning
compressor activated).
FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
Request to activate
the compressorET140:Air conditioning
requestACTIVE In the event of a fault, refer to the
interpretation of this status.
Passenger
compartment
blowerET141:Passenger
compartment
blowerRUNNINGIn the event of a fault, refer to the
interpretation of this status.
CompressorET020:Compressor
controlACTIVEIn the event of a fault, refer to the
interpretation of this status.
TemperaturePR001:Interior
temperatureX = interior
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)In the event of a fault, see the
interpretation of this
parameter.
PR002:External
temperatureX = exterior
temperature ± 5 ˚C
(invalid value: 215 ˚C)In the event of a fault, see the
interpretation of this
parameter
Note:
This parameter is displayed via
the climate control computer but
is generated by the UCH.
Air flapsPR012:Mixing flap
positionFrom 0 % (“Maximum
cold” position: 15 ˚C)
to 100 % (“Maximum
hot” position: 27 ˚C).In the event of a fault, see the
interpretation of this
parameter.
Page 40 of 99

62B-40
MR-413-X44-62B000$460_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
HEATING SUB-FUNCTION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning
compressor activated).
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Heated rear
screenET086: Heated rear
screen: manual
modeACTIVE: De-icing
request using the control
button.
INACTIVE otherwise.In the event of a fault, refer
to the interpretation of this
status.
ET085:Heated rear
screen:
automatic modeACTIVE: De-icing
request using the control
button. (“see clear”
function)
INACTIVE otherwise.In the event of a fault, refer
to the interpretation of this
status.
2Passenger
compartment
blowerET141:Passenger
compartment
blowerRUNNINGIn the event of a fault, refer
to the interpretation of this
status.
3Air mixing
motorPR012:Mixing flap
positionFrom 0 % (“Maximum
cold” position: 15 ˚C
to 100 % = “Maximum
hot” position: 27 ˚C).In the event of a fault, see
the interpretation of this
parameter.
4HeatingPR045:Current heating
resistor power0 < X < 900 WIn the event of a fault, see
the interpretation of this
parameter.
5TemperaturePR001:Interior
temperatureX = interior
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)In the event of a fault, see
the interpretation of this
parameter.
PR002: External
temperatureX = exterior
temperature ± 5 ˚C
(invalid value: 215 ˚C)In the event of a fault, see
the interpretation of this
parameter
Note:
This parameter is displayed
via the climate control
computer but is generated
by the UCH.
PR004:Coolant
temperatureX = engine coolant
temperature in ˚C.In the event of a fault, see
the interpretation of this
parameter.
Page 41 of 99

62B-41
MR-413-X44-62B000$460_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
MAIN SCREEN
NOTESOnly carry out this conformity check after a full check using the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning
compressor activated).
This page lists the statuses and parameters provided by the climate control computer
but which are not associated with the three sub-functions given in the conformity
check (PASSENGER COMPARTMENT VENTILATION, COLD LOOP and HEATING
sub-functions).
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Electrical
suppliesPR092:Battery voltage10.5 V < X <14.4 VIn the event of a fault, see
the interpretation of this
parameter.
ET083:+ 12 V after
ignition present PRESENT:
Ignition on.In the event of a fault, refer
to the interpretation of this
status.
ET002:+ 12 V side
lightsABSENT: Side lights off.
PRESENT: Side lights
on.In the event of a fault, refer
to the interpretation of this
status.
PR122:Night lighting
levelBetween 15 % (minimum
lighting level) and 99 %
(maximum lighting level)
(side lights off: 102 %)In the event of a fault,
consult the interpretation
of this parameter
Note:
This parameter is displayed
by the climate control
computer but is generated
by the instrument panel.
Page 43 of 99
62B-43
MR-413-X44-62B000$506_eng.mif
V1
CLIMATE CONTROL
Fault finding - Status summary table
Vdiag No.: 44
62B
ET002
+ 12 V SIDE LIGHTS FEED
NOTESNone
This status indicates the presence of + 12 V side lights feed on connection LPD of component 419.
If ET002 displays ABSENT when the side light are lit, check for + 12 V between connection LPD and the earth
connection NAM of component 419.
If + 12 V is present on connection LPD and ET002 displays ABSENT.
If the status does not operate, carry out fault finding on the UCH (see 87B, UCH).
If + 12 V is not present on connection LPD, consult ALP No. 13.
AFTER REPAIRRepeat the conformity check from the start.
CLIM_V44_ET012
Page 44 of 99
62B-44
MR-413-X44-62B000$506_eng.mif
V1
CLIMATE CONTROL
Fault finding - Status summary table
Vdiag No.: 44
62B
ET020
COMPRESSOR CONTROL
NOTESNone
This indicates the status of the compressor actuated by the injection computer.
If ET020 displays ACTIVE, the compressor activation request is authorised.
If ET020 displays INACTIVE, the compressor activation request is not authorised.
If the “AC” indicator light is lit and if ET020 displays INACTIVE, run fault finding on the injection computer
(see 13B, Diesel injection or 17B, Petrol injection) and UCH (see 87B, UCH).
AFTER REPAIRRepeat the conformity check from the start.
CLIM_V44_ET020