86A-57
AFTER REPAIRRepeat the conformity check from the start.
V2 MR-413-X44-86A100$160.mif
RADIO
Fault finding – Interpretation of parameters86A
R01-08
Vdiag No.: A4
PR005RADIO FIELD INTENSITY
NOTESThe values shown in this conformity check are given as a guide.
Test conditions: Engine off, ignition on and radio on.
Perform the conformity check outside, in an area with good radio reception
and without obstacles.
Conformity check:
Monitor the PR005 value of the diagnostic tool data display.
Display of frequency received for the radio station currently set.
Radio field intensity parameterRadio reception level
(data display)
Outdoor testUnit: dBµV
Data interpretation:
Radio reception value Status
X > 18 dBµVCorrect radio reception
14 dBµV < X < 18 dBµVCorrect sound quality
RDS decoding (for example: display of
station names) correct
Automatic synchronisation / Presence in
the radio list
not satisfactory
10 dBµV < X < 14 dBµVCorrect sound quality
RDS decoding (for example: display of
station names) not satisfactory
Automatic synchronisation / Presence in
the radio list
not satisfactory
X > 10 dBµVRadio reception not satisfactory
If the fault is still present, contact the Techline.
R108_VA4_PR005
RADIO
Fault finding – Interpretation of parameters