81C-6
MR-413-X44-81C000$400_eng.mif
V1
FUSE BOX
Fault finding chart81C
ALP 1
CONTINUED
NO
Test the continuity on connection BP12 between
component 104 and fuse MF-60A of component 597.
Is the continuity correct?
YES NO
Use a test light to check for + 12 V between
connection BPDA of component 597 and a chassis
earth.
Is the test light lit?
YES NO
Check fuse MF-60A of component 597. Carry out a continuity test on connection BPDA
between components 597 and 1033.
Is the fuse correct? Is the continuity correct?
YES NO YES NO
Replace the engine fuse
and relay box.Replace the fuse. Replace the battery Fault on connection A.
Repair the wiring. If there
is a repair procedure (see
Technical Note 6015A,
Repairing electrical
wiring, Wiring:
Precautions for repair),
repair the wiring,
otherwise replace it.
Fault on connection A. Repair the wiring. If there is a
repair procedure (see Technical Note 6015A,
Repairing electrical wiring, Wiring: Precautions
for repair), repair the wiring, otherwise replace it.
81C-25
MR-413-X44-81C000$600_eng.mif
V1
FUSE BOX
Fault finding chart81C
YES
Test the continuity on connection BP12 between
component 104 and fuse Max-60a of component 597.
Is the continuity correct?
YES NO
Use a test light to check for + 12 V between
connection BP12 of component 597 and a chassis
earth.
Is the test light lit?
YES NO
Carry out a continuity test on connection BPDA
between components 597 and 1033.Check the condition of fuse Max-60A of
component 597.
Is the continuity correct? Is the fuse correct?
YES NO YES NO
Replace the battery Fault on
connection BPDA.
Repair the wiring. If there
is a repair procedure (see
Technical Note 6015A,
Repairing electrical
wiring, Wiring:
Precautions for repair),
repair the wiring,
otherwise replace it.Replace the engine fuse
box.Replace the fuse of
component 597.
ALP 19
CONTINUED
Fault on connection BP12. Repair the wiring. If there is
a repair procedure (see Technical Note 6015A,
Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.