DIESEL INJECTION
Fault finding – Replacement of components13B
13B-24V3 MR-372-J84-13B250$225.mif
EDC16
PROGRAM No: C1
Vdiag No.: 51
REPLACING THE DAMPER VALVE
After replacing the damper valve, reconfigure the computer.
The system must be configured via the diagnostic socket using the RENAULT CLIP tool.
→ PROCEDURE to be followed after the damper valve is replaced:
–switch on the ignition,
–establish dialogue with the injection computer,
–run command SC036 Reset programming;
–select Damper valve as the operation type then follow the instructions given by the diagnostic tool,
–switch off the ignition,
–wait 1 min before switching on the ignition again,
–check that PR420 Damper valve error counter = 0;
–then check the system faults, and clear any stored faults;
–if there are faults, deal with the present faults,
–clear the faults from the computer memory.
Carry out a road test followed by a complete check with the diagnostic tool.
End of operation.
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-30V3 MR-372-J84-13B250$315.mif
DF001
PRESENT
OR
STOREDCOOLANT TEMPERATURE SENSOR CIRCUIT
CC.0 : Short circuit to earth
CO.1 : Short circuit or open circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present:
–when an attempt is made to start the engine,
–when the engine is running.
Special notes:
If the fault is present:
–the coolant temperature: PR064 Coolant temperature is fixed at 119˚C,
–the preheating phase is greater than 10 seconds,
–the low speed motor-driven fan assembly (GMV 1) is continuously supplied,
–if there is a fault with GMV 1, then start GMV 2 for vehicles with air conditioning.
–the level 1 warning light is lit,
–the OBD warning light will illuminate after three consecutive driving cycles (starting
+ 5 seconds + switching off the ignition and waiting 1 minute).
Use bornier Ele. 1681 or Ele. 1590 for all operations on the computer connectors.
Check the connections of the coolant temperature sensor 4-track connector.
Check the injection computer connections.
Repair if necessary.
Measure the resistance of the coolant temperature sensor between tracks 2 and 3 of its black connector.
Replace the sensor if its resistance is not approximately:
75780 ± 7000 Ω at - 40˚C
12460 ± 122 Ω at - 10˚C
2252 ± 112 Ω at 25˚C
811 ± 39 Ω at 50˚C
283 ± 8 Ω at 80˚C
115 ± 3 Ω at 110˚C
87 ± 2 Ω at 120˚C
Check the insulation, continuity and the absence of interference resistance on the following connections:
Injection computer brown 48-track connector B
track F2Track 3 coolant temperature sensor
Injection computer brown 48-track connector B
track H1Track 2 coolant temperature sensor
Repair if necessary.
If the fault is still present, replace the coolant temperature sensor.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16
PROGRAM No.: C1
Vdiag No.: 51DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16_V51_DF001
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-31V3 MR-372-J84-13B250$315.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF003
PRESENT
OR
STOREDATMOSPHERIC PRESSURE SENSOR CIRCUIT
1.DEF : Signal outside upper limit
2.DEF : Signal outside lower limit
3.DEF : Inconsistent signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present:
–when an attempt is made to start the engine,
–when the engine is running.
Special notes:
The atmospheric pressure sensor is integrated into the injection computer and cannot
be separated.
If the fault is present:
–there is light smoke at the exhaust,
–the atmospheric pressure value changes to safe mode, PR035 Atmospheric
pressure = 750 mbar.
–the level 1 warning light is lit,
–the OBD warning light will come on after three consecutive driving cycles (starting
+ 5 seconds + switching off the ignition and waiting 1 minute).
Use bornier Ele. 1681 or Ele. 1590 for all operations on the computer connectors.
Disconnect the injection computer and check the condition of the contacts and connector.
Repair if necessary.
Display the value of parameter PR041 Turbocharger pressure.
If this value is stuck at 750 mbar, refer to interpretation of fault DF004 Turbocharging pressure sensor circuit.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF003
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-38V3 MR-372-J84-13B250$315.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF007
CONTINUED 2
1.DEF
NOTESNone
Check the rail pressure sensor connectors.
Check the injection computer connections.
Repair if necessary.
Check for continuity and absence of interference resistance of the following connections:
Injection computer brown 48-track connector B
track G3Track 2 rail pressure sensor
Injection computer brown 48-track connector B,
track A4Track 3 rail pressure sensor
Injection computer brown 48-track connector B,
track C4Track 1 rail pressure sensor
Repair if necessary.
With the ignition on, and engine switched off for over 1 minute:
Display the parameter PR038 Rail pressure in the Fuel circuit, Engine control function tab,
–If the value is below 50 bar, the sensor is in order.
In this case, contact the Techline.
–If the pressure is above 50 bar, replace the rail pressure sensor and tighten to 35 ± 5 Nm.
Follow the recommended safety advice (see cleanliness advice).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-46V3 MR-372-J84-13B250$315.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF011
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE NO. 1
1.DEF : Sensor reference voltage too low
2.DEF : Sensor reference voltage too high
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after carrying out a road test or after several attempts at
starting the engine.
Special notes:
If the fault is present:
–the cruise control/speed limiter function is inhibited,
–turbocharging is inhibited,
–the engine speed is limited,
–the level 1 warning light is lit,
–the OBD warning light will come on after three consecutive driving cycles (starting
+ 5 seconds + switching off the ignition and waiting 1 minute).
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
1.DEF
2.DEF
NOTESPriorities when dealing with a number of faults:
If fault DF008 Pedal potentiometer circuit track 1 is
present at the same time, check that the sensor is connected
correctly.
In the event of the simultaneous presence of fault DF004
Turbocharging pressure sensor circuit, check that the
turbocharger pressure sensor circuit connector is connected
correctly.
The sensors connected to supply no. 1 are:
–Turbocharger pressure sensor.
–Accelerator pedal potentiometer sensor, gang 1.
To locate a faulty sensor and/or connection, disconnect one of these sensors then check whether the fault
becomes stored.
If the fault is still present, start the operation again with the other sensor.
(Wait a few seconds after each disconnection so that the computer can carry out the check).
If the fault is stored after a disconnection, replace the faulty sensor or repair its connection.
Clear the faults created by the multiple disconnections.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF011
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-48V3 MR-372-J84-13B250$315.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF012
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE No. 2
1.DEF : Sensor reference voltage too low
2.DEF : Sensor reference voltage too high
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present following a road test or after attempting to start the engine
several times.
Special notes:
If the fault is present:
–the EGR functions and passenger compartment heating resistance functions are
inhibited,
–the cruise control/speed limiter function is inhibited,
–the engine speed is limited,
–the level 1 warning light is lit,
–the OBD warning light will come on after three consecutive driving cycles (starting
+ 5 seconds + switching off the ignition and waiting 1 minute).
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
The sensors connected to feed no. 2 are:
–EGR valve position sensor.
–Accelerator pedal potentiometer sensor gang 2.
–Refrigerant pressure sensor.
To locate a faulty sensor and/or connection, disconnect one of these sensors then check whether the fault
becomes stored.
If the fault is still present, repeat the operation with the other sensors.
(Wait a few seconds after each disconnection so that the computer can carry out the check).
If the fault is stored after a disconnection, replace the faulty sensor or repair its connection.
Clear the faults created by the multiple disconnections.
Check the condition of the connector of the EGR valve position sensor, component code 1460, of the accelerator
pedal potentiometer sensor gang 2, component code 921 and of the refrigerant pressure sensor, component code
1202.
Check the condition of the injection computer connector, component code 120.
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF012
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-51V3 MR-372-J84-13B250$315.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF013
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE No. 3
1.DEF : Sensor reference voltage too low
2.DEF : Sensor reference voltage too high
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present following a road test or after attempting to start the engine
several times.
Special notes:
If the fault is present:
–the EGR function is inhibited,
–the engine stops,
–the level 2 warning light is lit,
–the OBD warning light will come on after three consecutive driving cycles (starting
+ 5 seconds + switching off the ignition and waiting 1 minute).
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
The sensors connected to supply no. 3 are:
–Rail pressure sensor.
–Air flow sensor..
To locate a faulty sensor and/or connection, disconnect one of these sensors then check whether the fault
becomes stored.
If the fault is still present, repeat the operation with the other sensors.
(Wait a few seconds after each disconnection so that the computer can carry out the check).
If the fault is stored after a disconnection, replace the faulty sensor or repair its connection.
Clear the faults created by the multiple disconnections.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF013
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-53V3 MR-372-J84-13B250$315.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF015
PRESENT
OR
STOREDMAIN RELAY control CIRCUIT
1.DEF : Relay cut off too soon
2.DEF : Relay cut off too late
NOTESConditions for applying the fault finding procedure to stored faults:
Only deal with this fault if it is stored.
Special notes:
The injection control unit supply relay (50A) is located on the relay plate in the
engine connection unit, under the Protection and Switching Unit.
If the fault is present, the level 1 warning light is lit.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
Check the Protection and Switching Unit connections.
Check the injection computer connections.
Repair if necessary.
Check the condition of the battery terminals making sure they are correctly tightened.
Check the condition of the injection supply relay and its mounting.
Check the 5D (5A) + after ignition feed injection fuse located on the UPC.
Repair if necessary.
Check the continuity, and absence of interference resistance of the following connection:
Injection computer brown 48-track connector B
track E1Track 2 injection supply relay mounting
Repair if necessary.
If the fault is still present, contact the Techline.
IMPORTANT!WARNING
If the UPC does not detect the injection computer frames the engine fan assembly 1
will be switched on until the battery is completely discharged.
In the event that engine cooling fan 1 is not working, GMV 2 will be supplied.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF015