AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 49V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF093
PRESENT
OR
STOREDMANUAL SEQUENTIAL CONTROLS CIRCUIT
CC.0 : Short circuit to earth
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after:
Lever in position "P", "R" or "N".
Gear lever in position "M+" or "M-".
Effect on system:
Impulse mode inhibited.
Customer complaint:
Impulse mode inhibited.
"Drive" position displayed on the instrument panel.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
Look for any damage to the harness and check the condition and connection of the connectors on the automatic
transmission computer and on the shift pattern control.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for earth on connection N+ of component 129.
Check the continuity and insulation against earth of the following connections:
●Connection code 5H.
●Connection code 5FM.
Between components 119 and 129.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
In the event of a fault, replace the shift pattern control.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF093/AJ0_V05_DF093
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 50V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF095
PRESENT
OR
STOREDSELECTOR LEVER LOCK ELECTROMAGNET CIRCUIT
1.DEF: Open circuit or short circuit
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after:
Lever in position "P" (without pressing the brake pedal), "R", "N", "D" or "M".
Customer complaint:
–in the event of open circuit or short circuit+:
The shift-lock solenoid valve cannot be activated: therefore the lever is placed in
position "P", blocking it. Unlocking is a manual operation.
–in the event of a CCM:
The shift-lock solenoid valve is always activated: therefore, no locking of lever.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
Look for any damage to the harness and check the condition and connection of the connectors on the automatic
transmission computer and on the shift pattern control.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection AP* of component 129.
Check for earth on connection N+ of component 129.
Check the insulation to earth and continuity of the following connection:
●Connection code 5DU, between components 119 and 129.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
In the event of a fault, replace the shift pattern control.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF095/AJ0_V05_DF095
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 52V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
Fault finding on sequence solenoid valve 2: DF097
CONTINUED 1
Look for any damage to the harness and check the condition and connection of the automatic transmission
computer and automatic transmission connectors.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection 5LW of component 754.
If + after ignition feed is present, move on to step 1.
If + after ignition feed is not present, move on to step 8.
Step 1:
Disconnect the connector from component 119, measure the resistance of sequence solenoid valve 2
(on the connector of component 119) between the following connections:
●Connection code 5CY.
●Connection code 5LW.
The resistance must be 28 ΩΩ Ω Ω
± 2.8 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, contact the Techline.
If NO, move on to step 2.
Step 2:
Disconnect connector R22 and check continuity and insulation of the following connections:
●Connection code 5CY.
●Connection code 5LW.
Between components 119 and R22.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Are the continuity and insulation correct?
If YES, move on to step 3.
If NO, replace the external wiring harness on the automatic transmission.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 54V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
Fault finding on lock-up/brake solenoid valve 1: DF097
CONTINUED 3
Stage 6:
Disconnect the connector from sequence solenoid valve 2, measure the resistance of sequence solenoid
valve 2 between the following connections:
●Connection code 5CY.
●Connection code 5LW.
The resistance must be 28 ΩΩ Ω Ω
± 2.8 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 7.
If NOT, replace the hydraulic distributor.
Step 7:
Measure the continuity and insulation of the following connections:
●Connection code 5CY.
●Connection code 5LW.
Between sequence solenoid valve 2 and the internal connector on the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the internal wiring harness on the automatic transmission.
Step 8:
Check the continuity and insulation of the following connection:
●Connection code 5LW between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If + after ignition feed is not present after checking feeds and computer earths on the transmission, contact the
Techline.
Look for any damage to the harness and check the condition and connection of the automatic transmission
computer and on the automatic transmission connectors.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection 5LW of component 754.
If + after ignition feed is present, move on to step 1.
If + after ignition feed is not present, move on to step 8.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 55V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF097
CONTINUED 4
Step 1:
Disconnect the connector from component 119, measure the resistance of the lock-up/brake solenoid valve
(on the connector of component 119) between the following connections:
●Connection code 5BF.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, contact the Techline.
If NO, move on to step 2.
Step 2:
Disconnect connector R22 and check continuity and insulation of the following connections:
●Connection code 5BF.
●Connection code 5LW.
Between components 119 and R22.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Are the continuity and insulation correct?
If YES, move on to step 3.
If NO, replace the external wiring harness on the automatic transmission.
Stage 3:
Measure the resistance of lock-up/brake 1 solenoid valve (on connector R22) between the following
connections:
●Connection code 5BF.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, and if the fault is still present, contact the Techline.
If NO, move on to step 4.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 57V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF097
CONTINUED 6
Step 7:
Measure the continuity and insulation of the following connections:
●Connection code 5BF.
●Connection code 5LW.
Between lock-up/brake solenoid valve 1 and the internal connector on the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the internal wiring harness on the automatic transmission.
Step 8:
Check the continuity and insulation of the following connection:
●Connection code 5LW between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If + after ignition feed is not present after checking feeds and earths on the transmission computer, contact the
Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 58V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
DF108
PRESENT
OR
STOREDAVERAGE EFFECTIVE TORQUE MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESCustomer complaint:
Fault warning light comes on.
If the fault occurs while driving, the transmission engages fixed 5th gear. Restarting
occurs in fixed 3rd gear (no more gear changes).
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
Run a multiplex network test (see 88B, Multiplex).
Carry out a test on the engine management computer (see 13B, Diesel injection, Conformity check) (EDC16
CP33 M9R 721).
Check the continuity and insulation against earth of the following connections:
●Connection code 3MS.
●Connection code 3MT.
Between components 119 and 120.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF108/AJ0_V05_DF108
MR-372-J84-23A000$450.mif
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 59V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF171
PRESENT
OR
STOREDVEHICLE SPEED SENSOR CIRCUIT
1.DEF: Open circuit or short circuit
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after a test.
The vehicle speed transmitted by the multiplex line > 12 mph (20 km/h) and the speed
of transmission output sensor < 3 mph (5km/h) then the vehicle speed transmitted by
multiplex line < 12 mph (20km/h).
Effect on system:
Impossible to calculate gear.
Customer complaint:
Gear on which fault occurred is fixed.
Restarting in fixed 3rd gear (no more gear changes).
Manual mode is inhibited.
Fault warning light comes on.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
Look for any damage to the wiring and check the condition and connection of the connectors for components 119
and 1060.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection AP4 of component 1060.
If + after ignition feed is present, move on to step 1.
If + after ignition feed is not present, move on to step 2.
Step 1:
Check the continuity and insulation of the following connections:
●Connection code 5TA.
●Connection code 5T.
Between components 119 and 1060.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the intermediate connector R22, if the fault is still present, replace component 1140.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF171/AJ0_V05_DF171