62B - 22
CLIMATE CONTROL
Fault finding – Interpretation of statuses62B
V3 MR-372-J84-62B000$070.mif
Vdiag No.: 44
CLIMATE CONTROL
Fault finding – Interpretation of statuses
ET007
COMPUTER + AFTER IGNITION FEED
NOTESNone.
This status shows the + 12 V after ignition feed supplied by the Protection and Switching Unit.
When the ignition is off, the status displays: ABSENT.
When the ignition is on, the status displays: PRESENT.
If the fault is still present, carry out fault finding on the Protection and Switching Unit: Check that status
ET003 After ignition relay control is working correctly and check that fault DF001 After ignition relay control
circuit is not present.
Carry out any repairs necessary (see corresponding fault finding procedures).
If the fault is still present: disconnect connector A (12-track) from the climate control computer to check the
insulation, continuity and absence of interference resistance of the following connections:
Computer connector A track 10 + accessories feed (7.5 A fuse in the Protection and
Switching Unit)
Computer connector A track 11 + before ignition feed (20 A fuse of the UCH)
Computer connector A track 6 Earth (left-hand dashboard beam)
Repair if necessary.
If the connections are correct and the climate control computer is correctly supplied but the fault is still present:
carry out fault finding on the electric charge circuit.
AFTER REPAIRRepeat the conformity check from the start.
ACREG X84 1.1
Edition 2
MR-372-J84-62B000$070.mif