2009 CHERY TIGGO check engine

[x] Cancel search: check engine

Page 315 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Check reference values between ECM terminals and ground under the following conditions:
ECM TERMINAL NO.ITEMCONDITIONDATA (DC VOLTAGE)
3 GND (I

Page 316 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 3.DETECT MALFUNCTIONING PART
•  Check the following:
� Fuse 17
� Harness connectors C-103, E-103, terminal 14
� Front fuse and relay box conn

Page 317 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 7.CHECK ECM POWER SUPPLY CIRCUIT - (2)
•  Check voltage between ECM terminals 44, 45, 63
 and ground.
•  Voltage: Turn ignition switch

on,

Page 318 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 10.CHECK STARTER RELAY (K4) CIRCUIT
• Disconnect ECM harness connector.
• Disconnect front fuse and relay box harness connector A.
• Chec

Page 321 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Check reference values between ECM terminals and ground under the following conditions:
ECM TERMINAL NO.ITEMCONDITIONDATA (AVERAGE DC
VOLTAGE)

Page 322 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Diagnostic Procedure
1.CHECK GROUND CONNECTIONS
• Turn ignition switch off.
• Loosen and retighten ground screws on the body (See Ground In

Page 323 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 4.DETECT MALFUNCTIONING PART
• Check the following:
1.6L Without EOBD � Front fuse and relay box G2, G5, A1, F3
� Fuse 23, fuse 12, fuse 24
W

Page 324 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 7.CHECK CMP SENSOR SIGNAL
• Turn ignition switch off.
• Connect CMP sensor connector.
• Check signal between CMP sensor terminal 2 and gr