Page 49 of 107

17C-49
MR-372-J84-17C000$413.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF098
PRESENT
OR
STOREDCYLINDER 1 INJECTOR CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Non-compliance with emission control standards
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety instructions (see 17D,
LPG injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with it first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode or when
command AC021 Cylinder 1 injector is executed.
Manipulate the wiring harness between the injection computer and the cylinder 1 injector in order to produce a change in
status
(present ↔ stored).
Look for any harness damage, and check the condition and connection points of the injector and its connections.
If necessary, repair or replace the connector.
Measure the resistance of injector 1 between tracks 1 and 2.
The injector resistance value at roughly 20 °C must be between:
0.77 Ω < R < 1.43 Ω
Replace the injector if necessary.
Check for insulation against earth, continuity and absence of interference resistance for the following connections:
For Mégane 2:
General relay track 5
Black intermediate connector (R37) track 5
LPG computer track G3
Black intermediate connector (R37) track 1
For Logan:
Injector 1 track 1
LPG computer track G3track 15 of the black intermediate connector (R37)
track 1 of injector 1
track 1 of the black intermediate connector (R37)
track 2 of injector 1
track A1 of the double relay control unit relay
track 2 of injector 1
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF098 / GAZ3000_V10_DF098
Page 51 of 107

17C-51
MR-372-J84-17C000$413.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF099
PRESENT
OR
STOREDINSTRUMENT PANEL INDICATOR LIGHT CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been started and switched to LPG
mode.
Special note:
Status ET099 LPG system faulty may help in dealing with this fault.
Check the insulation and continuity on the wires of the following multiplex connections:
For Mégane 2:
LPG computer track A1
LPG computer track A2
LPG computer track A2
For Logan:
LPG computer track C1
LPG computer track E1
LPG computer track D4track 17 of the instrument panel
track 18 of the instrument panel
track 4 of the instrument panel
track 23 of the instrument panel
track 11 of the instrument panel
track 19 of the instrument panel
Repair if necessary.
If the LPG in operation indicator light does not light up normally, carry out fault finding on the instrument
panel (see 83A, Instrument panel).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF099 / GAZ3000_V10_DF099
Page 52 of 107

17C-52
MR-372-J84-17C000$413.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF103
PRESENT
OR
STOREDLPG EXPANSION VALVE SOLENOID VALVE CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Non-compliance with emission control standards
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety instructions (see 17D,
LPG injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with it
first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode or
when command AC024 LPG expansion solenoid valve is executed.
Manipulate the wiring harness between the LPG computer and the LPG expansion valve solenoid valve in order
to produce a change in status (present ↔ stored).
Look for possible damage to the harness, and check the condition and connection of the LPG expansion valve
solenoid valve and its connectors.
Repair if necessary.
Measure the resistance between tracks 1 and 2 of the LPG expansion valve solenoid valve.
Replace the solenoid valve if the resistance is not approximately 12.6 Ω ± 1.3Ω .
Check the following connections for insulation from earth, continuity and absence of extraneous resistance:
For Mégane 2:
LPG expansion valve solenoid valve track 1
For Logan:
LPG expansion valve solenoid valve track 1
Intermediate connector (R674) track 1track 5 of the main relay
Intermediate connector (R674) track 1
track A3 of the main relay
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF103 / GAZ3000_V10_DF103
Page 55 of 107
17C-55
MR-372-J84-17C000$472.mif
V2
LPG 3000
Program No.
Vdiag No: 08/10GAS INJECTION
Fault finding - Conformity check17C
MAIN SCREEN (CONTINUED)
NOTESOnly perform this conformity check after a complete check with the diagnostic tool.
The values indicated in this conformity check are given as examples.
Application conditions: Engine stopped, ignition on and LPG mode selected.
Order FunctionParameter or Status
checked or ActionDisplay and notes Fault finding
9
TemperaturesPR103:Air temperature Indicates the temperature
–of water in °C.
–of air in °C.
–of gas in °C.
Check the consistency of the
temperatures by performing
fault finding on the petrol
computer.
With a cold engine,
the three temperatures
should be almost identical.In the event of a fault,
carry out a full fault
finding procedure on the
petrol injection system.
Deal with any other
faults. 10 PR002:Coolant
temperature
11 Gas temperature PR113:Gas temperatureNONE
Page 57 of 107

17C-57
MR-372-J84-17C000$472.mif
V2
LPG 3000
Program No.
Vdiag No: 08/10GAS INJECTION
Fault finding - Conformity check17C
SUB-FUNCTION: PETROL → LPG TRANSITION (CONTINUED)
NOTESOnly perform this conformity check after a complete check with the diagnostic tool.
The values indicated in this conformity check are given as examples.
Application conditions: Engine stopped, ignition on and LPG mode selected.
Order FunctionParameter or Status
checked or ActionDisplay and notes Fault finding
7
LPG / Petrol
switchET096:Petrol to LPG
TransitionNOWhen the LPG operating
mode has been selected, if
ET022 Waiting for LPG
conditions is NO and
ET100 LPG system ready
is YES, then ET096 Petrol
to LPG transition should
be YES. If there is
inconsistency, apply the
interpretation of status
ET096.
8ET093:LPG modeNOCheck the consistency
between statuses
ET094 Petrol mode
and ET093 LPG mode.
If there is inconsistency,
contact the Techline.
9
Petrol
injection
signalsPR006:Engine speedIndicates the engine's speed
of rotation in rpm.
PR006 = 0 rpmIn the event of a fault, carry
out a full fault finding
procedure on the petrol
injection system.
Deal with any other faults. 10 PR002:Coolant
temperatureIndicates the temperature
–of water in °C.
–of air in °C.
–of gas in °C.
Check the consistency of the
temperatures by performing
fault finding on the petrol
computer.
With a cold engine, the
three temperatures should be
almost identical. 11 PR103:Air
temperature
12LPG
temperaturePR113:LPG
TemperatureNONE
Page 59 of 107
17C-59
MR-372-J84-17C000$472.mif
V2
LPG 3000
Program No.
Vdiag No: 08/10GAS INJECTION
Fault finding - Conformity check17C
SUB-FUNCTION: LPG → PETROL TRANSITION
NOTESOnly perform this conformity check after a complete check with the diagnostic tool.
The values indicated in this conformity check are given as examples.
Application conditions: Engine switched off, ignition on and Petrol mode
selected.
Order FunctionParameter or Status
checked or ActionDisplay and
notesFault finding
7
Petrol injection
signalsPR006:Engine speedIndicates the engine's speed
of rotation in rpm.
PR006 = 0 rpm
In the event of a fault,
carry out a full fault
finding procedure on the
petrol injection system.
Deal with any other
faults. 8PR002:Coolant
temperature Indicates the temperature
–of water in °C.
–of air in °C.
Check the consistency of the
temperatures by performing
fault finding on the petrol
computer. With a cold
engine, the two
temperatures should be
almost identical. 9PR103:Air temperature
Page 64 of 107

17C-64
MR-372-J84-17C000$472.mif
V2
LPG 3000
Program No.
Vdiag No: 08/10GAS INJECTION
Fault finding - Conformity check17C
SUB-FUNCTION: OPERATION IN PETROL MODE (CONTINUED)
NOTESOnly perform this conformity check after a complete check with the diagnostic tool.
The values indicated in this conformity check are given as examples.
Application conditions: Engine switched off, ignition on and Petrol mode
selected.
Order FunctionParameter or Status
checked or ActionDisplay and notes Fault finding
7Fuel pump ET025:Fuel pumpACTIVEACTIVE when operating in
Petrol mode. If there is
inconsistency, carry out
a full fault finding procedure
on the petrol injection
system. Deal with any other
faults.
8
Petrol
injection
signalPR002:Coolant
temperatureIndicates the temperature
– of water in °C.
– of air in °C.
Check the consistency
of the temperatures by
performing fault finding on
the petrol computer.
With a cold engine, the two
temperatures should be
almost identical.In the event of a fault, carry
out a full fault finding
procedure on the petrol
injection system. Deal with
any other faults. 9PR103:Air temperature
Page 66 of 107
17C-66
MR-372-J84-17C000$472.mif
V2
LPG 3000
Program No.
Vdiag No: 08/10GAS INJECTION
Fault finding - Conformity check17C
MAIN SCREEN (CONTINUED)
NOTESOnly perform this conformity check after a complete check with the diagnostic tool.
The values indicated in this conformity check are given as examples.
Application conditions: Engine running at idle speed at 80°C and LPG mode
selected.
Order FunctionParameter or Status
checked or ActionDisplay and notes Fault finding
9
Temperatures PR103:Air temperatureIndicates the temperature
– of water in °C.
– of air in °C.
Check the consistency of the
temperatures by performing
fault finding on the petrol
computer.In the event of a fault, carry
out a full fault finding
procedure on the petrol
injection system.
Deal with any other faults. 10 PR002:Coolant
temperature
11LPG
temperaturePR113:LPG temperatureGives the LPG temperature
in °C.
- 40°C < PR113 < 120°CNONE