17C-25
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF020
PRESENT
OR
STOREDFUEL SENDER SWITCHING RELAY CIRCUIT
CC.1: Short circuit to + 12 Volts
CO.0: Open circuit or short circuit to earth
2.DEF: Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode
or when command AC005 Fuel sender relay is executed.
Manipulate the wiring harness between the LPG computer and the fuel sender relay in order to produce a change
in status (present ↔ stored).
Look for possible damage to the wiring harness and check the connection and condition of the fuel sender relay
and its connections.
Repair if necessary.
Check the continuity and insulation of the following connection:
Fuel sender relay track 5 track E3, LPG computer
Replace the fuse if necessary.
With the ignition on, check for +12V on track C1 of the LPG computer.
Check the insulation in relation to earth and the continuity and the absence of interference resistance on
the connection between:
LPG computer track C1 track B1 of the LPG or petrol selector switch
If the fault is still present, check the intermediate connector (R34 on track 7, for Mégane 2 and R212 on
track B6, for Logan).
Repair if necessary.
Check the insulation in relation to earth and the continuity and the absence of interference resistance on
the connection between:
LPG computer track E4 track 2 of the fuel sender relay
Repair if necessary.
In LPG operation, check for earth on track 2 of the fuel sender relay.
If, with the ignition on, the computer does not control the fuel sender relay on track 2 via an earth, contact
the Techline.
If the fault is still present, replace the fuel sender relay.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF020 / GAZ3000_V10_DF020
17C-26
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF021
PRESENT
OR
STOREDLPG TANK SOLENOID VALVE RELAY CIRCUIT
CC.1: Short circuit to + 12 Volts
CO.0: Open circuit or short circuit to earth
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
If fault DF024 Fuel pump cut-off relay circuit is present or stored, deal with this fault
first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been started and switched to LPG
mode.
Manipulate the wiring harness between the LPG computer and the LPG tank solenoid valve relay in order to
produce a change in status (present ↔ stored).
Look for possible damage to the wiring harness and check the condition and connection of the LPG tank
solenoid valve relay and its connections.
If necessary, repair or replace the connector.
With the ignition on, check for + 12V on track 1 of the LPG tank solenoid valve relay and track C2 of the LPG
computer.
If no + 12 V:
–disconnect the battery,
–in the Protection and Switching Unit, disconnect the grey connector,
–check the cleanliness and condition of the connections,
–Use the universal bornier to check the continuity of the following connection:
For Mégane 2:
Protection and Switching Unit, grey connector, track 1
For Logan:
Fuse box, track S4track 3 of the main relay
track A5 of the main relay
Repair if necessary.
Check for + 12V on track 3 of the LPG tank solenoid valve relay.
If + 12V is not present, use the universal bornier to check the continuity of the following connection:
For Mégane 2:
Tank solenoid valve relay track 3
For Logan:
Double control relay unit track B3track 5 of the fuel pump relay
track B5 of the fuel pump relay
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF021 / GAZ3000_V10_DF021
17C-27
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF021
CONTINUED
Check the insulation in relation to + 12V and the continuity and absence of interference resistance on
the connection between:
For Mégane 2:
LPG computer track E4
For Logan:
LPG computer track E4track 2 of the gas tank solenoid valve relay
track B2 of the double control relay unit
Repair if necessary.
With the ignition on, check for earth on track 2 of the LPG tank solenoid valve relay.
If, with the ignition on, the computer does not control the LPG tank solenoid valve relay on track 2 through an
earth, contact the Techline.
With the engine running, check that the relay clicks when LPG mode is selected.
If the fault is still present, replace the LPG tank solenoid valve relay.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
17C-29
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF024
PRESENT
OR
STOREDFUEL PUMP CUT-OFF RELAY CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 Volts
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with
this fault first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been running for 10 seconds in
LPG mode.
Manipulate the wiring harness between the LPG computer and the fuel pump cut-off relay in order to produce
a change in status (present ↔ stored).
Look for any damage to the wiring harness and check the connection and condition of the fuel pump cut-off
relay and its connections.
Check the insulation in relation to earth and the continuity and the absence of interference resistance on
the connection between:
For Mégane 2:
Main relay track 5
For Logan:
Double control relay unit track A3track 1 of the fuel pump cut-off relay
track B5 of the fuel pump cut-off relay
Repair if necessary.
Check the insulation in relation to + 12V and the continuity and absence of interference resistance on
the connection between:
LPG computer track F3 track 2 of the fuel pump cut-off relay
Repair if necessary.
In LPG operating mode, using status ET025 Fuel pump, check that status ET025 is ACTIVE when starting
and then changes to INACTIVE after 1 minute.
If ET025 does not change to INACTIVE, check for earth on track 2 of the fuel pump cut-off relay.
If, with the ignition on, the computer does not control the fuel pump cut-off relay on track 2 through an earth,
contact your Techline.
If the fault is still present, replace the fuel pump cut-off relay.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF024 / GAZ3000_V10_DF024
17C-38
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF081
PRESENT
OR
STOREDCYLINDER 2 INJECTOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 Volts
1.DEF: Non-compliance with emission control standards
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with
this fault first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode
or when command AC020 Cylinder 2 injector is executed.
Manipulate the wiring harness between the LPG computer and Injector number 2 until there is a change in status.
(present ↔ stored).
Look for any damage to the wiring harness and check the connection and condition of injector 2 and its
connections.
If necessary, repair or replace the connector.
Measure the resistance of injector 2 between tracks 1 and 2.
Replace the injector if the resistance value of the injector at approximately 20°C is not between:
0.7 Ω < R < 1.45 Ω
Check for insulation against earth, continuity and absence of interference resistance for the following
connections:
For Mégane 2:
General relay track A5
Black intermediate connector (R37) track 6
LPG computer track G4
Black intermediate connector (R37) track 2
For Logan:
Injector 2 track 1
LPG computer track G4track 6 of the black intermediate connector (R37)
track 1of injector 2
track 2 of the black intermediate connector (R37)
track 2 of injector 2
track A1 of the double control relay unit
track 2 of injector 2
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF081 / GAZ3000_V10_DF081
17C-41
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF087
PRESENT
OR
STOREDCYLINDER 4 INJECTOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 Volts
1.DEF: Non-compliance with emission control standards
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with
this fault first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode
or when command AC018 Cylinder 4 injector is executed.
Manipulate the wiring harness between the LPG computer and Injector number 4 to produce a change in status.
(present ↔ stored).
Look for any harness damage, and check the condition and connection of injector no. 4 and its connectors.
If necessary, repair or replace the connector.
Measure the resistance of injector 4 between tracks 1 and 2.
The injector resistance value at approximately 20°C should be between:
0.7 Ω < R < 1.45 Ω
Replace the injector if necessary.
Check for insulation against earth, continuity and absence of interference resistance for the following
connections:
For Mégane 2:
General relay track 5
Black intermediate connector (R37) track 8
LPG Computer track H3
Black intermediate connector (R37) track 4
For Logan:
Injector 4 track 1
LPG Computer track H3track 8 of the black intermediate connector (R37)
track 1of injector 4
track 4 of the black intermediate connector (R37)
track 2 of injector 4
track A1 of the double control relay unit
track 2 of injector 4
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF087 / GAZ3000_V10_DF087
17C-43
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF088
PRESENT
OR
STOREDCYLINDER 3 INJECTOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 Volts
1.DEF: Non-compliance with emission control standards
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with
this fault first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode
or when command AC019 Cylinder 3 injector is executed.
Manipulate the wiring harness between the LPG computer and Injector number 3 to produce a change in status.
(present ↔ stored).
Look for any damage to the wiring harness and check the connection and condition of the injector and its
connections.
If necessary, repair or replace the connector.
Measure the resistance of injector 3 between tracks 1 and 2.
The injector resistance value at approximately 20°C should be between:
0.7 Ω < R < 1.45 Ω
Replace the injector if necessary.
Check for insulation against earth, continuity and absence of interference resistance for the following
connections:
For Mégane 2:
General relay track 5
Black intermediate connector (R37) track 7
LPG computer track H2
Black intermediate connector (R37) track 3
For Logan:
Injector 3 track 1
LPG computer track H2track 7 of the black intermediate connector (R37)
track 1of injector 3
track 3 of the black intermediate connector
track 2 of injector 3
track A1 of the double control relay unit
track 2 of injector 3
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF088 / GAZ3000_V10_DF088
17C-49
MR-372-J84-17C000$413.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF098
PRESENT
OR
STOREDCYLINDER 1 INJECTOR CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Non-compliance with emission control standards
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety instructions (see 17D,
LPG injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with it first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode or when
command AC021 Cylinder 1 injector is executed.
Manipulate the wiring harness between the injection computer and the cylinder 1 injector in order to produce a change in
status
(present ↔ stored).
Look for any harness damage, and check the condition and connection points of the injector and its connections.
If necessary, repair or replace the connector.
Measure the resistance of injector 1 between tracks 1 and 2.
The injector resistance value at roughly 20 °C must be between:
0.77 Ω < R < 1.43 Ω
Replace the injector if necessary.
Check for insulation against earth, continuity and absence of interference resistance for the following connections:
For Mégane 2:
General relay track 5
Black intermediate connector (R37) track 5
LPG computer track G3
Black intermediate connector (R37) track 1
For Logan:
Injector 1 track 1
LPG computer track G3track 15 of the black intermediate connector (R37)
track 1 of injector 1
track 1 of the black intermediate connector (R37)
track 2 of injector 1
track A1 of the double relay control unit relay
track 2 of injector 1
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF098 / GAZ3000_V10_DF098