86D-39
MR-372-J84-86D000$952.mif
V2
Multimedia network
interface unit
Vdiag No.: 04, 14MULTIMEDIA NETWORK INTERFACE UNIT
Fault finding - Fault Finding Chart86D
ALP 1
CONTINUED 1
Check for + 12 V battery feed on the following connections of component 225:
–BP32 (Scénic II ph2).
–BCP4 (Espace IV ph2).
–BP10 (Trafic II ph2).
–BP32 (Kangoo 2).
Check for + 12 V after ignition feed on the following connections of component 225:
–AP43 (Scénic II ph2).
–AP10 (Espace IV ph2).
–AP26 (Trafic II ph2).
–AP43 (Kangoo 2).
Check for an earth on the following connections of component 225:
–NC and MB (Espace IV ph2).
–MAM and NAM (Scénic II ph2).
–NJ and MJ (Trafic II ph2).
–NAM and MN (Kangoo 2).
Check for + 12 V battery feed on the following connections of the connector for component 1714:
–BCP4 (Kangoo 2).
–BCP4 (Trafic II ph2).
–BP3A (Espace IV ph2).
–BCP3 (Scénic II ph2).
Check for an earth on the following connections of the connector for component 1714:
–MAN (Kangoo 2),
–MAN (Trafic II ph2 and Scénic II ph2),
–NC (Espace IV ph2).
AFTER REPAIRCarry out a complete check with the diagnostic tool.