Page 29 of 63
83A-29
MR-372-J84-83A000$567.mif
V8
INSTRUMENT PANEL
Fault finding - Interpretation of statuses83A
TDB ph2 (EG/MG)
Prog Version: 04xx
Vdiag No.: 08, 0C
ET066
BRAKE FLUID LEVEL LIGHT WARNING
NOTESThere must be no present or stored faults.
Check the brake fluid level in the reservoir.
If status ET066 Brake fluid level warning light is PRESENT and the level is correct, disconnect the connector
on the brake fluid reservoir level switch.
If the status ET066 Brake fluid level warning light becomes ABSENT, replace the switch.
Check the insulation and continuity of the connection between:
Grey connector level sensor track 2 track 20 of the instrument panel connector
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
AFTER REPAIRCarry out another fault finding check on the system.
Deal with any other faults.
Clear the stored faults.
TDB_V08_ET066/TDB_V0C_ET066
Page 31 of 63

83A-31
MR-372-J84-83A000$567.mif
V8
INSTRUMENT PANEL
Fault finding - Interpretation of statuses83A
TDB ph2 (EG/MG)
Prog Version: 04xx
Vdiag No.: 08, 0C
ET097
PARKING BRAKE
NOTESSpecial notes:
Only apply the checks if the APPLIED and RELEASED statuses are not consistent
with the lever position:
–APPLIED when the lever is released.
–RELEASED when the lever is applied.
STATUS
"APPLIED" when
the lever is
releasedCheck that the handbrake switch is correctly connected and check the condition of the
connections.
Repair if necessary.
With the lever released, check continuity is absent on the following connection:
Handbrake switch track 1 Vehicle earth
If there is continuity, replace the switch.
Check the insulation of the following connection:
Instrument panel track 21 Track 1 of the handbrake switch
If there is a repair method (see Technical note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair) repair the wiring, otherwise replace it.
RELEASED
STATUS when the
lever has been
pulled upCheck that the handbrake switch is correctly connected and check the condition of the
connections.
Repair if necessary.
With the lever pulled up, check continuity on the following connection:
Handbrake switch track 1 Vehicle earth
If there is no continuity, replace the switch.
Check the insulation of the following connection:
Instrument panel track 21 Track 1 of the handbrake switch
If there is a repair method (see Technical note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair) repair the wiring, otherwise replace it.
AFTER REPAIRCarry out another fault finding check on the system.
Deal with any other faults.
Clear the stored faults.
TDB_V08_ET097/TDB_V0C_ET097
Page 44 of 63

83A-44
MR-372-J84-83A000$819.mif
V8
INSTRUMENT PANEL
Fault finding - Interpretation of commands83A
TDB ph2 (EG/MG)
Prog Version: 04xx
Vdiag No.: 08, 0C
AC009
INSTRUMENT PANEL WARNING LIGHTS
NOTESThere must be no present or stored faults.
Activate the instrument panel warning lights using command AC009 Instrument panel warning lights.
The indicator lights are all on, check that the lights are correct.
Check the condition and connection of the instrument panel 24-track grey connector.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
Check the condition and connection of the 4-track seat belt warning module black connector.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
Check the insulation, continuity and the absence of interference resistance on the following connections:
Instrument panel grey connector, track 16 Track 3 of the seat belt warning module
connector
Instrument panel grey connector, track 23 Track 4 of the seat belt warning module
connector
Instrument panel grey connector, track 12 Track 1 of the seat belt warning module
connector
Instrument panel grey connector, track 11 Track 2 of the seat belt warning module
connector
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
If the fault is still present, contact Techline.
AFTER REPAIRRepeat the conformity check from the start.
Page 48 of 63

83A-48
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 1No communication with the instrument panel.
The instrument panel does not light up.
NOTESOnly consult this customer complaint after a complete check with the diagnostic tool.
See Wiring Diagram Technical Note for Scénic II.
Look for possible damage to the wiring harness.
Check the connection and condition of the instrument panel connector, component code 247.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation, continuity and the absence of interference resistance of the following connections:
•BP79 between components 247 and 260,
•MAM (if left-hand drive) or MAN (if right-hand drive) between component 247 and the earth,
•153A between components 247 and 1232,
•153B between components 247 and 1232.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact Techline.
TDB_V08_ALP1/TDB_V0C_ALP1
INSTRUMENT PANEL
Fault finding - Fault finding chart
Page 49 of 63

83A-49
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 2 The fuel level indicator does not display full
NOTESThe fuel tank must be filled with the ignition switched off (advise the customer to remove
the key).
Ideally the customer must fill the tank with at least 15 litres.
See Wiring Diagram Technical Note for Scénic II.
Ask the customer if the tank is filled up under the
following conditions:
–the customer filled the tank up to the 3
rd cut-out
–the customer has changed filling station
–the customer filled the tank in a flat-level station (not
on a slope).
Did the customer fill the tank while observing all of
these conditions?Ask the customer to return just after
having filled the tank under the conditions
mentioned above.
NO
YES
A
TDB_V08_ALP2/TDB_V0C_ALP2
Page 51 of 63

83A-51
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 2
CONTINUED 2
Check the continuity, insulation and absence of
interference resistance on the following
connections:
•41A between components 247 and 199,
•41B between components 247 and 199.
Are the checks correct?
Measure the resistance of the sender and the wiring
using a multimeter via the connector, on the
instrument panel side.
Is the value measured and the value provided by
the CLIP tool the same as or approximately
± 5 ΩΩ Ω Ω
?Contact the Techline.
Replace the instrument panel, component code 247
(see MR 370, Mechanical, 83A, Instrument panel,
Instrument panel: Removal - Refitting).
Is the fault still present?The problem disappears.
C
NO
NOD
YES
YES
NO
NO
YES
B
Page 52 of 63
83A-52
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 2
CONTINUED 3
If the connection or connections are faulty and
there is a repair procedure (see Technical Note
6015A, Electrical wiring repair, Wiring:
Precautions for repair), repair the wiring,
otherwise replace the wiring.
Is the fault still present?
The problem disappears.
D
NO
YESB
NO
Page 56 of 63

83A-56
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 5Fault with no warning given by warning light (no addition of fuel
since the fault)
NOTESPut the vehicle in + after ignition.
See Wiring Diagram Technical Note for Scénic II.
Check the instrument panel warning lights, component code
247.Replace the instrument panel,
component code 247 (see MR
370, Mechanical, 83A,
Instrument panel, Instrument
panel: Removal - Refitting). Does the fuel warning light illuminate for 3 seconds when
+ after ignition is switched on?
Record the resistance value provided by the CLIP tool.
Compare the value from the CLIP tool with the warning
resistance, which is 290 ΩΩ Ω Ω
.
Is this value above or equal to 290 ΩΩ Ω Ω
?Contact the Techline.
Rock the vehicle and check whether the resistance changes by
± 5 ΩΩ Ω Ω
.
Is there a change in the resistance value?Contact the Techline.
NO
YES
YES
NO
YES
NO
A
TDB_V08_ALP5/TDB_V0C_ALP5