Page 3234 of 4083
![INFINITI QX56 2008 Factory Service Manual SEC-26
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
B2013 ID DISCORD I-KEY-STRG
B2013 ID DISCORD I-KEY-STRG
DescriptionINFOID:0000000001539123
Intelligent Key unit performs the ID verification INFINITI QX56 2008 Factory Service Manual SEC-26
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
B2013 ID DISCORD I-KEY-STRG
B2013 ID DISCORD I-KEY-STRG
DescriptionINFOID:0000000001539123
Intelligent Key unit performs the ID verification](/manual-img/42/57030/w960_57030-3233.png)
SEC-26
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
B2013 ID DISCORD I-KEY-STRG
B2013 ID DISCORD I-KEY-STRG
DescriptionINFOID:0000000001539123
Intelligent Key unit performs the ID verification with the
steering lock solenoid and releases the steering lock if
both Intelligent Key unit and steering lock solenoid ID are same. Intelligent Key unit starts the communication
with the steering lock solenoid when Intelligent Key is carried into the vehicle and the ignition knob switch is
pressed.
DTC LogicINFOID:0000000001539124
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Press the ignition knob switch.
2. Check “Self diagnostic result” with CONSULT-III.
Is DTC detected?
YES >> Refer to SEC-26, "Diagnosis Procedure".
NO >> Inspection End.
Diagnosis ProcedureINFOID:0000000001539125
1.PERFORM INITIALIZATION
Perform initialization with CONSULT-III. Re-register all mechanical keys.
For initialization and registration of mechanical key. Refer to “CONSULT-III Operation Manual”.
Can the system be initialized and can steering lo ck be released with re-registered mechanical key?
YES >> Steering lock solenoid was unregistered.
NO >> GO TO 2
2.CHECK STEERING LOCK SOLENOID POWER SUPPLY-1
1. Turn ignition switch OFF.
2. Disconnect steering lock solenoid connector.
3. Check voltage between steering lock solenoid harness connec- tor and ground.
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair or replace harness.
3.CHECK STEERING LOCK SOLENOID GROUND CIRCUIT
DTC No.Trouble diagnosis
name DTC detecting condition
Possible cause
B2013 STRG COMM 1 The ID verification results between Intelligent Key
unit and steering control unit are NG. The registra-
tion is necessary.
Steering lock solenoid
Te r m i n a l s
Voltage (V)(Approx.)
(+)
(–)
Steering lock solenoid con-
nector Te r m i n a l
M15 1Ground Battery voltage
WIIA1202E
Revision: March 2010 2008 QX56
Page 3245 of 4083
![INFINITI QX56 2008 Factory Service Manual B2552 INTELLIGENT KEYSEC-37
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
SEC
N
O P
B2552 INTELLIGENT KEY
DescriptionINFOID:0000000001539141
Intelligent key unit perfor INFINITI QX56 2008 Factory Service Manual B2552 INTELLIGENT KEYSEC-37
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
SEC
N
O P
B2552 INTELLIGENT KEY
DescriptionINFOID:0000000001539141
Intelligent key unit perfor](/manual-img/42/57030/w960_57030-3244.png)
B2552 INTELLIGENT KEYSEC-37
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
SEC
N
O P
B2552 INTELLIGENT KEY
DescriptionINFOID:0000000001539141
Intelligent key unit performs engine start operation and steering lock control by crosschecking ID with the Intel-
ligent key.
DTC LogicINFOID:0000000001539142
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON.
2. Check “Self diagnostic result” with CONSULT-III.
Is DTC detected?
YES >> Refer to SEC-37, "Diagnosis Procedure".
NO >> Inspection End.
Diagnosis ProcedureINFOID:0000000001539143
1.REPLACE INTELLIGENT KEY UNIT
1. Replace Intelligent Key unit.
2. Perform initialization with CONSULT- III. Re-register all mechanical keys. Refer to “CONSULT-III Opera-
tion Manual”.
3. Start the engine.
Does the engine start?
YES >> Inspection End.
NO >> Perform “DTC confirmation procedure”. Refer to SEC-37, "
DTC Logic".
Special Repair RequirementINFOID:0000000001539144
1.REQUIRED WORK WHEN REPLACING INTELLIGENT KEY UNIT
Initialize control unit. Refer to CONSULT-III Operation Manual.
>> Work end.
DTC No. Trouble diagnosis
name DTC detecting condition
Possible cause
B2552 INTELLIGENT KEY
UNIT Malfunction is detected inside Intelligent
key unit.
Intelligent Key unit
Revision: March 2010
2008 QX56
Page 3249 of 4083
POWER SUPPLY AND GROUND CIRCUITSEC-41
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
SEC
N
O P
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check voltage between BCM harness connector and ground.
Is the measurement value normal?
YES >> GO TO 3
NO >> Repair or replace harness.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
Does continuity exist?
YES >> INSPECTION END
NO >> Repair or replace harness.
Connector Te r m i n a l s
Power
source Condition Voltage (V) (Ap-
prox.)
(+) (-)
M18 11 Ground
ACC
power
supply Ignition
switch
ACC or
ON Battery voltage
38 Ground Ignition
power
supply Ignition
switch ON or START Battery voltage
M20 57 Ground
Battery
power
supply Ignition
switch OFF Battery voltage
70 Ground Battery
power
supply Ignition
switch
OFF Battery voltage
LIIA2415E
BCM
GroundContinuity
Connector Terminal
M20 67 Yes
LIIA0915E
Revision: March 2010 2008 QX56
Page 3251 of 4083
![INFINITI QX56 2008 Factory Service Manual KEY CYLINDER SWITCHSEC-43
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
SEC
N
O P
3. Check continuity between front door lock assembly LH (key cyl- inder switch) connec INFINITI QX56 2008 Factory Service Manual KEY CYLINDER SWITCHSEC-43
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
SEC
N
O P
3. Check continuity between front door lock assembly LH (key cyl- inder switch) connec](/manual-img/42/57030/w960_57030-3250.png)
KEY CYLINDER SWITCHSEC-43
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
SEC
N
O P
3. Check continuity between front door lock assembly LH (key cyl- inder switch) connector (A) D14 terminal 5 and body ground.
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair or replace harness.
3.CHECK DOOR KEY CYLINDER SWITCH LH
Check continuity between front door lock assembly LH (key cylinder
switch) terminals.
Is the inspection result normal?
YES >> GO TO 4
NO >> Replace front door lock assembly LH (key cylinder switch). Refer to DLK-232, "
Removal and
Installation".
4.CHECK DOOR KEY CYLINDER HARNESS
Check continuity between main power window and door lock/unlock
switch connector (A) D7 terminals 4, 6 and front door lock assembly
LH (key cylinder switch) connector (B) D14 terminals 1, 6 and body
ground.
Is the inspection result normal?
YES >> Replace main power window and door lock/unlock switch.
NO >> Repair or replace harness.
Connector TerminalsContinuity
D14 5 – Ground Yes
WIIA0813E
TerminalsCondition Continuity
1 – 5 Key is turned to UNLOCK or neutral.
No
Key is turned to LOCK. Yes
5 – 6 Key is turned to LOCK or neutral.
No
Key is turned to UNLOCK. Yes
LIIA1573E
Connector Terminals Connector Terminals Continuity
A: Main
power win-
dow and
door lock/ unlock
switch 4 B: Front
door lock
assembly LH (key
cylinder switch) 1Y
es
66Y es
4, 6 Ground No
WIIA0814E
Revision: March 2010 2008 QX56
Page 3252 of 4083
![INFINITI QX56 2008 Factory Service Manual SEC-44
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
IGNITION KNOB SWITCH
IGNITION KNOB SWITCH
Ignition Knob
Switch CheckINFOID:0000000001539156
1.CHECK IGNITION KNOB SWITCH
With CONSULT-III
D INFINITI QX56 2008 Factory Service Manual SEC-44
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
IGNITION KNOB SWITCH
IGNITION KNOB SWITCH
Ignition Knob
Switch CheckINFOID:0000000001539156
1.CHECK IGNITION KNOB SWITCH
With CONSULT-III
D](/manual-img/42/57030/w960_57030-3251.png)
SEC-44
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
IGNITION KNOB SWITCH
IGNITION KNOB SWITCH
Ignition Knob
Switch CheckINFOID:0000000001539156
1.CHECK IGNITION KNOB SWITCH
With CONSULT-III
Display “PUSH SW” on DATA MONITOR screen, and check if ON/OFF display is linked to ignition switch oper-
ation.
Without CONSULT-III
1. Turn ignition switch OFF.
2. Disconnect Intelligent Key unit connector.
3. Check voltage between Intelligent Key unit harness connector M70 terminal 27 and ground.
Is the inspection result normal?
YES >> Ignition knob switch is OK.
NO >> GO TO 2
2.CHECK IGNITION KNOB SWITCH POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect key switch and ignition knob switch connector.
3. Check voltage between key switch and ignition knob switch harness connector M12 terminal 1 and ground.
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair or replace key switch and ignition knob switch power supply circuit.
3.CHECK IGNITION KNOB SWITCH OPERATION
Check continuity between key switch and ignition knob switch terminals 1 and 2.
Monitor item Condition
PUSH SW Ignition switch is pushed: ON
Ignition switch is released: OFF
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
M70 27 Ground Ignition switch is
pushed
Battery voltage
Ignition switch is re-
leased 0
WIIA1175E
1 - Ground
: Battery voltage
PIIB4257E
Revision: March 2010 2008 QX56
Page 3253 of 4083
IGNITION KNOB SWITCHSEC-45
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
SEC
N
O P
Is the inspection result normal?
YES >> GO TO 4
NO >> Replace key switch and ignition knob switch.
4.CHECK IGNITION KN OB SWITCH CIRCUIT
1. Check continuity between Intelligent Key unit harness connector (A) M70 terminal 27 and key switch and ignition knob switch harness c onnector (B) M12 terminal 2.
2. Check continuity between Intelligent Key unit harness connector M70 terminal 27 and ground.
Is the inspection result normal?
YES >> Check the condition of harness and harness connector.
NO >> Repair or replace harness between Intelligent Key unit and key switch and ignition knob switch.
Component Terminals ConditionContinuity
Ignition
knob switch 12 Ignition switch is pushed Yes
Ignition switch is released No
PIIA9929E
27 - 2
: Continuity should exist.
27 - Ground : Continuity should not exist.
WIIA1176E
Revision: March 2010 2008 QX56
Page 3254 of 4083
![INFINITI QX56 2008 Factory Service Manual SEC-46
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
HOOD SWITCH
HOOD SWITCH
Diagnosis ProcedureINFOID:0000000001602186
1.CHECK HOOD SWITCH
Check hood switch and hood fitting condition.
Is the INFINITI QX56 2008 Factory Service Manual SEC-46
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
HOOD SWITCH
HOOD SWITCH
Diagnosis ProcedureINFOID:0000000001602186
1.CHECK HOOD SWITCH
Check hood switch and hood fitting condition.
Is the](/manual-img/42/57030/w960_57030-3253.png)
SEC-46
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
HOOD SWITCH
HOOD SWITCH
Diagnosis ProcedureINFOID:0000000001602186
1.CHECK HOOD SWITCH
Check hood switch and hood fitting condition.
Is the inspection result normal?
YES >> GO TO 2
NO >> Adjust installation of hood switch.
2.CHECK HOOD SWITCH INPUT SIGNAL
With CONSULT-III
Check "HOOD SW" in "BCM" DATA MONI TOR mode with CONSULT-III. Refer to SEC-21, "
THEFT ALM :
CONSULT-III Function (BCM - THEFT ALM)".
Without CONSULT-III
Check voltage between IPDM E/R harness connector E122 terminal
41 and ground.
Is the inspection result normal?
YES >> Hood switch is OK.
NO >> GO TO 3
3.CHECK HOOD SWITCH SIGNAL CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector E122 and hood switch connector.
3. Check continuity between IPDM E/R connector (A) E122 termi- nal 41 and hood switch connector (B) E8 terminal 1.
4. Check continuity between IPDM E/R connector (A) E122 termi- nal 41 and ground.
Is the inspection result normal?
YES >> GO TO 4
NO >> Repair or replace harness.
4.CHECK HOOD SWITCH GROUND CIRCUIT
Check continuity between hood switch connector E8 terminal 2 and ground. When hood is open : HOOD SW ON
When hood is closed : HOOD SW OFF
Connector
Te r m i n a l
Condition of
hood Voltage (V)
(Approx.)
(+) (-)
E122 41Ground Open
0
Closed Battery voltage
WIIA0601E
Te r m i n a l s Continuity
IPDM E/R
Connector Te r m i n a l
Hood switch
connector Te r m i n a l
E122 41E81Yes
IPDM E/R Connector Terminals Continuity
E122 41 Ground No
ALKIA1785ZZ
Revision: March 2010 2008 QX56
Page 3255 of 4083
HOOD SWITCHSEC-47
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
SEC
N
O P
Is the inspection result normal?
YES >> GO TO 5
NO >> Repair or replace harness.
5.CHECK HOOD SWITCH
Check continuity between hood switch terminals 1 and 2.
Is the inspection result normal?
YES >> Replace IPDM E/R. Refer to PCS-34, "Removal and
Installation of IPDM E/R".
NO >> Replace hood switch.
Connector Terminals Continuity
E8 2Ground Yes
ALKIA1786ZZ
Terminals ConditionContinuity
1- 2 Pressed
No
Released Yes
ALKIA1787ZZ
Revision: March 2010 2008 QX56