3 - 3
INSP
ADJ
MAINTENANCE INTERVALS
FRONT FORKS
Inspect and adjust
Replace oilSuspension oil “S1”
Replace oil seal
FRONT FORK OIL SEAL AND DUST SEAL
Clean and lubeLithium base grease
PROTECTOR GUIDE
Replace
REAR SHOCK ABSORBER
Inspect and adjust
Lube(After
rain
ride)Molybdenum disulfide
grease
Retighten
DRIVE CHAIN GUIDE AND ROLLERS
Inspect
SWINGARMMolybdenum disulfide
grease
Inspect, lube and retighten
RELAY ARM, CONNECTING ROD Molybdenum disulfide
grease
Inspect, lube and retighten
SIDESTAND
LubricateLithium base grease
STEERING HEAD
Inspect free play and retighten
Clean and lubeLithium base grease
Replace bearing
TIRE, WHEELS
Inspect air pressure, wheel run-out, tire
wear and spoke looseness
Retighten sprocket bolt
Inspect bearings
Replace bearings
LubricateLithium base grease
THROTTLE, CONTROL CABLE Yamaha cable lube or SAE
10W-30 motor oil
Check routing and connection
Lubricate
HOT STARTER, CLUTCH LEVER
Inspect free play
BATTERY
Check terminal for looseness and
corrosionItemAfter
break-inEvery
race
Every third
(or
500 km)Every fifth
(or
1,000 km)As
requiredRemarks
3 - 125
INSP
ADJ
BATTERY INSPECTION AND
CHARGING
WARNING
Batteries generate explosive
hydrogen gas and contain electro-
lyte which is made of poisonous
and highly caustic sulfuric acid.
Therefore, always follow these
preventive measures:
Wear protective eye gear when
handling or working near batter-
ies.
Charge batteries in a well-venti-
lated area.
Keep batteries away from fire,
sparks or open flames (e.g.,
welding equipment, lighted ciga-
rettes).
DO NOT SMOKE when charging
or handling batteries.
KEEP BATTERIES AND ELEC-
TROLYTE OUT OF REACH OF
CHILDREN.
Avoid bodily contact with elec-
trolyte as it can cause severe
burns or permanent eye injury.
FIRST AID IN CASE OF BODILY
CONTACT:
EXTERNAL
Skin — Wash with water.
Eyes — Flush with water for 15
minutes and get immediate med-
ical attention.
INTERNAL
Drink large quantities of water
or milk followed with milk of
magnesia, beaten egg or vegeta-
ble oil. Get immediate medical
attention.
CAUTION:
Charging time, charging amper-
age and charging voltage for an
MF battery are different from
those of conventional batteries.
The MF battery should be charged
as explained in the charging
method illustrations. If the battery
is overcharged, the electrolyte
level will drop considerably.
Therefore, take special care when
charging the battery.
NOTE:Since MF batteries are sealed, it is
not possible to check the charge
state of the battery by measuring the
specific gravity of the electrolyte.
Therefore, the charge of the battery
has to be checked by measuring the
voltage at the battery terminals. CONTROLE ET CHARGE DE LA
BATTERIE
AVERTISSEMENT
Les batteries produisent de l’hydro-
gène, un gaz explosif et contiennent de
l’électrolyte, composé d’acide sulfuri-
que, toxique et corrosif.
Il faut dès lors veiller à toujours pren-
dre les précautions suivantes:
Toujours porter des lunettes de pro-
tection lorsque l’on travaille à
proximité de batteries.
Charger les batteries dans un
endroit bien aéré.
Tenir les batteries à l’écart de tout
feu, étincelles ou flamme nue (équi-
pement de soudure, cigarette, etc.).
NE PAS FUMER en chargeant ou
manipulant des batteries.
TENIR BATTERIES ET ELEC-
TROLYTE HORS DE LA POR-
TEE DES ENFANTS.
Eviter tout contact avec l’électro-
lyte, car il peut gravement brûler la
peau et les yeux.
PREMIERS SOINS EN CAS DE
CONTACT DIRECT:
EXTERNE
Peau — Laver à l’eau.
Yeux — Rincer à l’eau pendant 15
minutes et consulter immédiatement
un médecin.
INTERNE
Boire une grande quantité d’eau ou
de lait, continuer avec du lait de
magnésie, un oeuf battu ou de
l’huile végétale. Consulter immédia-
tement un médecin.
ATTENTION:
La durée, l’intensité et la tension de
charge d’une batterie sans entretien
MF et d’une batterie classique sont
différentes. La batterie MF doit être
rechargée conformément à la méthode
de charge illustrée dans ce manuel. Si
l’on surcharge la batterie, son niveau
d’électrolyte diminuera considérable-
ment. Il convient donc de charger la
batterie avec beaucoup de prudence.
N.B.:
Les batteries sans entretien (MF) sont
scellées; il est donc impossible de véri-
fier leur état de charge en mesurant la
densité de l’électrolyte. Par conséquent,
vérifier la charge de la batterie en mesu-
rant la tension aux bornes de la batterie.
ELECTRICAL
PARTIE ELECTRIQUE
3 - 127
INSP
ADJ
1. Remove:
Seat
2. Disconnect:
Battery leads
(from the battery terminals)
CAUTION:
First, disconnect the negative bat-
tery lead 1, and then the positive
battery lead 2.
3. Remove:
Battery band
Battery
4. Measure:
Battery charge
ÈRelationship between the open-circuit
voltage and the charging time at 20 °C
(68 °F) (These values vary with the
temperature, the condition of the
battery plates, and the electrolyte
level.)
ÉOpen-circuit voltage
ÊCharging time (hours)
ËTime (minutes)
ÌCharging condition of the battery
ÍAmbient temperature 20 °C (68 °F)
aCharging
bCheck the open-circuit voltage
Measurement steps:
Connect a pocket tester
1 to
the battery terminals.
Tester positive probe →
battery positive terminal
Tester negative probe →
battery negative terminal
NOTE:The charge state of an MF bat-
tery can be checked by measur-
ing its open-circuit voltage (i.e.,
the voltage when the positive
terminal is disconnected).
No charging is necessary when
the open-circuit voltage equals
or exceeds 12.8 V.
Check the charge of the battery,
as shown in the charts and the
following example.
Example
Open-circuit voltage = 12.0 V
Charging time = 6.5 hours
Charge of the battery = 20 ~ 30%
È
1. Déposer:
Selle
2. Déconnecter:
Câbles de la batterie
(des bornes de la batterie)
ATTENTION:
Déconnecter d’abord le câble négatif
de batterie 1, puis le câble positif 2.
3. Déposer:
Sangle de la batterie
Batterie
4. Mesurer:
Charge de la batterie
È
Relation entre la tension en circuit ouvert
et le temps de charge à 20 °C (68 °F)
(Ces valeurs varient en fonction de la
température, de l’état des plaques de la
batterie et du niveau d’électrolyte.)
É
Tension en circuit ouvert
Ê
Durée de charge (heures)
Ë
Durée (minutes)
Ì
Etat de charge de la batterie
Í
Température ambiante 20 °C (68 °F)
a
Charge
b
Vérifier la tension en circuit ouvert
Etapes de la mesure:
Raccorder un multimètre 1 aux
bornes de la batterie.
Sonde positive du multimètre →
borne positive de la batterie
Sonde négative de la batterie →
borne négative de la batterie
N.B.:
On peut contrôler l’état de charge
d’une batterie sans entretien (MF)
en mesurant la tension entre ses
bornes en circuit ouvert (après
avoir déconnecté la borne posi-
tive).
Inutile de recharger tant que la ten-
sion en circuit ouvert est supé-
rieure ou égale à 12,8 V.
Contrôler la charge de la batterie,
conformément aux diagrammes et
à l’exemple suivant.
Exemple
Tension en circuit ouvert = 12,0 V
Temps de charge = 6,5 heures
Charge de la batterie = 20 à 30 %
ELECTRICAL
PARTIE ELECTRIQUE
3 - 129
INSP
ADJ
5. Charge:
Battery
(refer to the appropriate charg-
ing method illustration)
WARNING
Do not quick charge a battery.
CAUTION:
Never remove the MF battery
sealing caps.
Do not use a high-rate battery
charger since it forces a high-
amperage current into the bat-
tery quickly and can cause bat-
tery overheating and battery
plate damage.
If it is impossible to regulate the
charging current on the battery
charger, be careful not to over-
charge the battery.
When charging a battery, be
sure to remove it from the
machine. (If charging has to be
done with the battery mounted
on the machine, disconnect the
negative battery lead from the
battery terminal.)
To reduce the chance of sparks,
do not plug in the battery
charger until the battery charger
leads are connected to the bat-
tery.
Before removing the battery
charger lead clips from the bat-
tery terminals, be sure to turn
off the battery charger.
Make sure the battery charger
lead clips are in full contact with
the battery terminal and that
they are not shorted. A corroded
battery charger lead clip may
generate heat in the contact
area and a weak clip spring may
cause sparks.
If the battery becomes hot to the
touch at any time during the
charging process, disconnect
the battery charger and let the
battery cool before reconnect-
ing it. Hot batteries can explode!
As shown in the following illus-
tration, the open-circuit voltage
of an MF battery stabilizes about
30 minutes after charging has
been completed. Therefore, wait
30 minutes after charging is
completed before measuring the
open-circuit voltage. 5. Charger:
batterie
(se reporter à l’illustration de la
méthode de charge appropriée)
AVERTISSEMENT
Ne pas utiliser la méthode de charge
rapide pour recharger cette batterie.
ATTENTION:
Ne jamais ôter les bouchons d’une
batterie sans entretien (MF).
Ne pas utiliser un chargeur de bat-
terie à intensité élevée. En effet, un
ampérage trop élevé risque de pro-
voquer la surchauffe de la batterie
et l’endommagement des plaques de
la batterie.
S’il n’est pas possible de régler le
courant de charge de la batterie,
bien veiller à ne pas surcharger la
batterie.
Toujours déposer la batterie avant
de procéder à sa charge. (Si la batte-
rie doit être chargée sur la moto,
déconnecter le câble négatif de la
borne de la batterie.)
Afin de réduire le risque de produc-
tion d’étincelles, ne pas brancher le
chargeur de batterie avant d’avoir
connecté les câbles du chargeur à la
batterie.
Ne pas oublier de couper l’alimenta-
tion du chargeur avant de retirer les
pinces du chargeur des bornes de la
batterie.
Veiller à assurer un contact électri-
que parfait entre les pinces du char-
geur et les bornes de la batterie. Ne
jamais laisser les pinces entrer en
contact l’une avec l’autre. Une pince
de chargeur corrodée risque de pro-
voquer un échauffement de la batte-
rie sur la zone de contact et des
pinces lâches peuvent provoquer
des étincelles.
Si la batterie devient chaude au tou-
cher pendant la charge, débrancher
le chargeur de batterie et laisser
refroidir la batterie avant de la
rebrancher. Une batterie chaude
risque d’exploser !
Comme montré dans le schéma sui-
vant, la tension en circuit ouvert
d’une batterie MF se stabilise envi-
ron 30 minutes après la fin du char-
gement. Par conséquent, attendre
30 minutes avant de mesurer la ten-
sion en circuit ouvert.
ELECTRICAL
PARTIE ELECTRIQUE
3 - 131
INSP
ADJ
ELECTRICAL
Charging method using a variable voltage charger
Connect a charger and
ammeter to the battery
and start charging.
Is the amperage higher
than the standard charg-
ing amperage written on
the battery?NO YES Charger
Ammeter
Adjust the voltage to obtain
the standard charging amper-
age.
Set the timer to the charging
time determined by the open-
circuit voltage.
Refer to “BATTERY
INSPECTION AND CHARG-
ING” section.Adjust the charging voltage to
20 ~ 25 V.
Monitor the amperage for
3 ~ 5 minutes. Is the standard
charging amperage exceeded?
NO YES
If the amperage does not
exceed the standard charg-
ing amperage after 5 minutes,
replace the battery.
If the required charging time exceeds 5 hours, it is advisable to check
the charging amperage after 5 hours. If there is any change in the
amperage, readjust the voltage to obtain the standard charging amper-
age.
Leave the battery unused for more than 30 minutes before measuring
its open-circuit voltage.
12.8 V
→ Charging is complete.
12.0 ~ 12.7 V
→ Recharging is required.
Under 12.0 V
→ Replace the battery.
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
Set the charging voltage to 16-
17 V. (If the charging voltage is
lower, charging will be insuffi-
cient, if it is higher, the battery will
be over-charged.) NOTE:
NOTE:
Measure the open-circuit
voltage prior to charging.
3 - 132
INSP
ADJ
ELECTRICAL
Charging method using a constant voltage charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery
and start charging.
NO
YESIs the amperage higher
than the standard charg-
ing amperage written on
the battery?
Charge the battery until the charging
voltage reaches 15 V.
Leave the battery unused for more than 30
minutes before measuring its open-circuit
voltage.
12.8 V
→ Charging is complete.
12.0 ~ 12.7 V
→ Recharging is required.
Under 12.0 V
→ Replace the battery.This type of battery charger cannot
charge an MF battery. A variable
voltage charger is recommended.Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage. NOTE:
Set the charging time to a maxi-
mum of 20 hours. NOTE:
Constant amperage chargers
are not suitable for charging
MF batteries.
CAUTION:
Charger
Ammeter
Voltmeter
3 - 141
INSP
ADJ
6. Install:
Battery
Battery band
7. Connect:
Battery leads
(to the battery terminals)
CAUTION:
First, connect the positive lead 1,
then the negative lead 2.
8. Check:
Battery terminals
Dirt
→ Clean with a wire
brush.
Loose connection
→ Connect
properly.
9. Lubricate:
Battery terminal
10. Install:
Seat
Recommended
lubricant:
Lithium soap base
grease
BATTERY REPLACEMENT
1. Replace:
Battery
CAUTION:
This battery is for YAMAHA
WR250F.
After filling the battery with elec-
trolyte, either charge it for at least
3 hours at the amperage specified
on the battery or let it sit for at
least 15 hours before using it.
EAS00181 FUSE INSPECTION
CAUTION:
To avoid a short circuit, always set
the main switch to “OFF” when
checking or replacing a fuse.
1. Remove:
Seat
Fuse cover6. Monter:
Batterie
Sangle de la batterie
7. Connecter:
Câbles de la batterie
(aux bornes de la batterie)
ATTENTION:
Connecter d’abord le câble positif 1,
puis le câble négatif 2.
8. Contrôler:
Bornes de la batterie
Saleté → Nettoyer avec une
brosse métallique.
Connexion lâche → Brancher
correctement.
9. Lubrifier:
Bornes de la batterie
10. Monter:
Selle
Lubrifiant recommandé:
graisse à savon de
lithium
REMPLACEMENT DE LA
BATTERIE
1. Remplacer:
Batterie
ATTENTION:
Cette batterie est destinée à la
YAMAHA WR250F.
Après avoir rempli la batterie d’élec-
trolyte, la charger pendant au moins 3
heures à l’ampérage spécifié sur la
batterie ou la laisser reposer pendant
au moins 15 heures avant de l’utiliser.
CONTROLE DES FUSIBLES
ATTENTION:
Pour éviter un court-circuit, toujours
placer le contacteur à clé sur “OFF”
avant de contrôler ou de remplacer un
fusible.
1. Déposer:
Selle
Couvercle de la boîte à fusibles
ELECTRICAL
PARTIE ELECTRIQUE
5 - 211
ENGENGINE REMOVAL
Extent of removal:
1 Engine removal
Extent of removal Order Part name Q’ty Remarks
Ignition coil
Disconnect the AC magneto lead.
Starter motor lead Disconnect at the starter motor side.
Negative battery lead Disconnect at the engine side.
1 Engine guard 1
2 Neutral switch 1
3 Drive chain sprocket cover 1
4 Nut (drive sprocket) 1
Refer to “REMOVAL POINTS”. 5 Lock washer 1
6 Drive sprocket 1
7 Clip 1
8 Bolt (brake pedal) 1
9 Brake pedal 1
10 Upper engine bracket 2
11 Lower engine bracket 2
12 Engine mounting bolt 3
13 Pivot shaft 1
Refer to “REMOVAL POINTS”.
14 Engine 1
1