BRAKE SIGNAL CIRCUIT
AT-185
D
E
F
G
H
I
J
K
L
MA
B
AT
Revision: 2007 April2007 M35/M45
BRAKE SIGNAL CIRCUITPFP:25320
CONSULT-II Reference ValueNCS001PT
Diagnostic ProcedureNCS001PU
1. CHECK CAN COMMUNICATION LINE
Perform the self-diagnosis. Refer to AT- 9 2 , "
SELF-DIAGNOSTIC RESULT MODE" , AT- 1 0 3 , "Diagnostic Pro-
cedure without CONSULT-II" .
Is a malfunction in the CAN communication indicated in the results?
YES >> Check CAN communication line. Refer to AT- 1 0 5 , "DTC U1000 CAN COMMUNICATION LINE" .
NO >> GO TO 2.
2. CHECK STOP LAMP SWITCH CIRCUIT
With CONSULT-II
1. Turn ignition switch ON.
2. Select “ECU INPUT SIGNALS” in “DATA MONITOR” mode for
“A/T” with CONSULT-II.
3. Read out ON/OFF switching action of the “BRAKE SW”.
OK or NG
OK >>INSPECTION END
NG >> GO TO 3.
3. CHECK STOP LAMP SWITCH
Check continuity between stop lamp switch harness connector termi-
nals. Refer to AT- 1 8 7 , "
Wiring Diagram — AT — NONDTC" .
Check stop lamp switch after adjusting brake pedal — refer to
BR-6, "
BRAKE PEDAL" .
OK or NG
OK >> Check the following. If NG, repair or replace damaged
parts.
Harness for short or open between battery and stop lamp switch.
Harness for short or open between stop lamp switch and unified meter and A/C amp.
10A fuse (No.20, located in fuse block).
NG >> Repair or replace the stop lamp switch.
Item name Condition Display value
BRAKE SWDepressed brake pedal. ON
Released brake pedal. OFF
Item name Condition Display value
BRAKE SWDepressed brake pedal. ON
Released brake pedal. OFF
PCIA0070E
Condition Continuity
When brake pedal is depressed Yes
When brake pedal is released No
SCIA4782E
A/T SHIFT LOCK SYSTEM
AT-233
D
E
F
G
H
I
J
K
L
MA
B
AT
Revision: 2007 April2007 M35/M45
3. DETECT MALFUNCTIONING ITEM
Check the following.
Harness for short or open between battery and stop lamp switch harness connector E124 terminal 1
Harness for short or open between stop lamp switch harness connector E124 terminal 2 and shift lock
relay E35 terminal 2
10A fuse [No.20, located in the fuse block (J/B)]
Stop lamp switch
–Check continuity between stop lamp switch harness connector E124 terminals 1 and 2
Check stop lamp switch after adjusting brake pedal — refer to BR-6, "
BRAKE PEDAL" .
ICC brake hold relay. Refer to ACS-69, "ICC Brake Hold Relay" . (With ICC only)
Harness for short or open between battery and ICC brake hold relay E80 terminal 3. Refer to ACS-50,
"DTC 13 STOP LAMP RLY FIX" . (With ICC only)
Harness for short or open between ICC brake hold relay E80 terminal 5 and shift lock relay E35 terminal
2. (With ICC only)
Harness for short or open between ICC sensor integrated unit harness connector E61 terminal 2 and ICC
brake hold relay E80 terminal 2. Refer to ACS-50, "
DTC 13 STOP LAMP RLY FIX" . (With ICC only)
Harness for short or open between ICC brake hold relay E80 terminal 1 and ground. Refer to ACS-50,
"DTC 13 STOP LAMP RLY FIX" . (With ICC only)
OK or NG
OK >> GO TO 4.
NG >> Repair or replace damaged parts.
4. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect shift lock relay.
3. Check continuity between shift lock relay E35 terminal 1 and
ground.
CAUTION:
Connect test probe (BLACK) to shift lock relay, and test
probe (RED) to ground.
If OK, check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
SCIA4990E
Continuity should exist.
SCIA6931E
AT-234
A/T SHIFT LOCK SYSTEM
Revision: 2007 April2007 M35/M45
5. CHECK INPUT SIGNAL A/T DEVICE
1. Turn ignition switch OFF.
2. Disconnect A/T device harness connector.
3. Turn ignition switch ON.
4. Check voltage between A/T device harness connector M133 ter-
minal 7 and ground.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING ITEM
Check the following.
Harness for short or open between push-button ignition switch and shift lock relay E35 terminal 5
Harness for short or open between shift lock relay E35 terminal 3 and A/T device harness connector
M133 terminal 7
10A fuse [No.12, located in the fuse block (J/B)]
Push-button ignition switch (Refer to PG-3, "POWER SUPPLY ROUTING CIRCUIT" .)
Shift lock relay
–Check continuity between shift lock relay E35 terminal 3 and 5
OK or NG
OK >> GO TO 7.
NG >> Repair or replace damaged parts.
7. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect A/T device harness connector.
3. Check continuity between A/T device harness connector M133
terminal 8 and ground.
If OK, check harness for short to ground and short to power.
OK or NG
OK >> GO TO 8.
NG >> Repair open circuit or short to ground or short to power
in harness or connectors. Vo l ta g e
Brake pedal depressed: Battery voltage
Brake pedal released: 0 V
SCIA6867E
Condition Continuity
12V direct current supply between terminal 1 and 2 Yes
OFF No
SCIA1245E
Continuity should exist.
SCIA6868E
PRECAUTIONS
ATC-11
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2007 April2007 M35/M45
VK45DE
CAUTION:
The new and former refrigerant connections use different O-ring configurations. Never confuse O-
rings since they are not interchangeable. If a wrong O-ring is installed, refrigerant may leak at the con-
nection.
O-Ring Part Numbers and Specifications
RJIA4011E
Connection type Piping connection point Part number QTY O-ring size
NewLow-pressure flexible hose to low-pressure pipe 1 (One-
touch joint)92473 N8221 2 16
High-pressure pipe 1 to high-pressure pipe 2 (One-touch
joint)92471 N8221 2 8
Condenser to high-pressure flexible hose (One-touch joint) 92472 N8221 2 12
Condenser to high-pressure pipe 1 (One-touch joint) 92471 N8221 2 8
Low-pressure pipe to low-pressure flexible hose (VK45DE) 92474 N8210 1 19
Low-pressure pipe 1 to expansion valve 92473 N8210 1 16
High-pressure pipe 2 to expansion valve 92471 N8210 1 8
Compressor to low-pressure flexible hose (VQ35DE)
92474 N8210 1 19
Compressor to low-pressure pipe (VK45DE)
Compressor to high-pressure flexible hose 92472 N8210 1 12
Liquid tank to condenser pipeInlet
92471 N82101
8
Outlet 1
FormerRefrigerant pressure sensor to liquid tank J2476 89956 1 10
Expansion valve to evaporatorInlet 92475 71L00 1 12
Outlet 92475 72L00 1 16
TROUBLE DIAGNOSIS
ATC-69
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2007 April2007 M35/M45
1. CHECK POWER SUPPLY CIRCUIT FOR UNIFIED METER AND A/C AMP.
1. Disconnect unified meter and A/C amp. connector.
2. Check voltage between unified meter and A/C amp. harness
connector M65 terminals 41, 53 and 55 and ground.
OK or NG
OK >> GO TO 2.
NG >> Check 10A fuses [Nos. 6, 12 and 19, located in the fuse block (J/B)]. Refer to PG-114, "
FUSE
BLOCK - JUNCTION BOX (J/B)" .
If fuses are OK, check harness for open circuit. Repair or replace if necessary.
If fuses are NG, check harness for short circuit and replace fuse.
2. CHECK GROUND CIRCUIT FOR UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Check continuity between unified meter and A/C amp. harness
connector M65 terminal 55, 71 and ground.
OK or NG
OK >> Replace unified meter and A/C amp.
NG >> Repair harness or connector.
Terminals Ignition switch position
(+)
(-) OFF ACC ON Unified
meter and
A/C amp.
connectorTerminal
No.
M65 41
GroundApprox. 0 VBattery
voltageBattery
voltage
M65 53 Approx. 0 V Approx. 0 VBattery
voltage
M65 54Battery
voltageBattery
voltageBattery
voltage
RJIA4050E
55, 71 – Ground : Continuity should exist.
RJIA4051E
ATC-70
TROUBLE DIAGNOSIS
Revision: 2007 April2007 M35/M45
Rear Control Switch CircuitNJS000GM
DIAGNOSIS PROCEDURE FOR REAR CONTROL SWITCH
SYMPTOM: Rear control switch does not operate.
1. CHECK A/C SYSTEM
Check multifunction switch, confirm A/C system operation.
OK or NG
OK >> GO TO 2.
NG >> Go to trouble diagnosis procedure for A/C system. Refer to AT C - 6 7 , "
Power Supply and Ground
Circuit for Auto Amp." .
2. CHECK REAR CONTROL SWITCH
Check rear control switch, except for A/C switch (audio) operation.
OK or NG
OK >> GO TO 5.
NG >> GO TO 3.
3. CHECK POWER SUPPLY FOR REAR CONTROL SWITCH
1. Turn ignition switch OFF.
2. Disconnect rear control switch connector.
3. Turn ignition switch ACC.
4. Check voltage between rear control switch harness connector
B554 terminal 1 and ground.
OK or NG
OK >> GO TO 4.
NG >> Check 10A fuse [No. 6 located in the fuse block (J/B)].
Refer to PG-114, "
FUSE BLOCK - JUNCTION BOX (J/
B)" .
If fuse is OK, check harness for open circuit. Repair or replace if necessary.
If fuse is NG, check harness for short circuit and replace fuse.
4. CHECK GROUND CIRCUIT FOR REAR CONTROL SWITCH
1. Turn ignition switch OFF.
2. Check continuity between rear control switch harness connector
B554 terminal 4 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
5. CHECK REAR CONTROL SWITCH, AV CONTROL UNIT OR NAVI CONTROL UNIT
Check circuit between rear control switch and AV control unit or NAVI control unit. Refer to AV- 1 0 8 , "
TROU-
BLE DIAGNOSIS" (Without mobile entertainment system) or AV- 2 4 9 , "TROUBLE DIAGNOSIS" (With mobile
entertainment system).
OK or NG
OK >> Replace rear control switch.
NG >> Replace part or repair for result trouble diagnosis.1 – Ground : Battery voltage
RJIA3996E
4 – Ground : Continuity should exist.
RJIA3997E
TROUBLE DIAGNOSIS
ATC-91
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2007 April2007 M35/M45
1. CHECK POWER SUPPLY FOR BLOWER MOTOR
1. Disconnect blower motor connector.
2. Turn ignition switch ON.
3. Check voltage between blower motor harness connector M91
terminal 1 and ground.
OK or NG
OK >> GO TO 2.
NG >> Check power supply circuit and 15A fuses [Nos. 10 and
11, located in the fuse block (J/B)]. Refer to PG-114,
"FUSE BLOCK - JUNCTION BOX (J/B)" .
If fuses are OK, check harness for open circuit. Repair or replace if necessary.
If fuses are NG, check harness for short circuit and replace fuse.
2. CHECK BLOWER MOTOR GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between blower motor harness connector M91
terminal 3 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connector.
3. CHECK CIRCUIT CONTINUITY BETWEEN BLOWER MOTOR AND UNIFIED METER AND A/C AMP.
1. Disconnect unified meter and A/C amp. connector.
2. Check continuity between blower motor harness connector M91
terminal 2 and unified meter and A/C amp. harness connector
M64 terminal 38.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.1 – Ground : Battery voltage
RJIA1997E
3 – Ground : Continuity should exist.
RJIA4072E
2 – 38 : Continuity should exist.
RJIA4073E
TROUBLE DIAGNOSIS
ATC-95
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: 2007 April2007 M35/M45
1. CHECK AMBIENT SENSOR AND INTAKE SENSOR CIRCUIT
Check ambient sensor and intake sensor. Refer to AT C - 5 7 , "
FUNCTION CONFIRMATION PROCEDURE" ,
see No. 9 and 11.
OK or NG
OK >> GO TO 2.
NG >>
Malfunctioning ambient sensor: Refer to AT C - 11 2 , "Ambient Sensor Circuit" .
Malfunctioning intake sensor: Refer to ATC-121, "Intake Sensor Circuit" .
2. PERFORM AUTO ACTIVE TEST
Refer to PG-23, "
Auto Active Test" .
Does the magnet clutch operate?
YES >>WITH CONSULT-II: GO TO 5.
WITHOUT CONSULT-II: GO TO 6.
NO >> Check 10A fuse (No. 79, located in IPDM E/R). Refer to PG-28, "
IPDM E/R Terminal Arrange-
ment" , and GO TO 3.
3. CHECK CIRCUIT CONTINUITY BETWEEN IPDM E/R AND COMPRESSOR
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and compressor connector.
3. Check continuity between IPDM E/R harness connector E8 ter-
minal 34 and compressor harness connector F24 terminal 1.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.
4. CHECK MAGNET CLUTCH CIRCUIT
Check for operation sound when applying battery voltage direct cur-
rent to terminal.
OK or NG
OK >> 1. Replace IPDM E/R.
2. Go to self-diagnosis procedure AT C - 5 7 , "
FUNCTION
CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-4. Confirm that magnet clutch opera-
tion normal.
NG >> 1. Replace compressor.
2. Go to self-diagnosis procedure AT C - 5 7 , "
FUNCTION
CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-4. Confirm that magnet clutch operation normal.
34 – 1 : Continuity should exist.
RJIA4079E
RJIA2005E