Page 72 of 400
4-15
w
8Always set the parking brake before start-
ing the engine. The ATV could start mov-
ing unexpectedly if the parking brake is
not applied. This could cause loss of con-
trol or a collision.
8Always be sure you have released the
parking brake before you begin to ride. The
brake could overheat if you ride the ATV
without releasing the parking brake. You
could lose braking performance which
could cause an accident. You could also
wear out the brakes prematurely.
1
1. Locked position
1. Verrouillé
1. Posición bloqueada
Page 294 of 400
8-49
NOTE:
The air filter element should be cleaned every
20-40 hours. It should be cleaned and lubricated
more often if the machine is operated in
extremely dusty areas. Each time the air filter
element maintenance is performed, check the
air inlet to the filter case for obstructions. Check
the air filter case rubber joint to the carburetor
and manifold fittings for an airtight seal. Tighten
all fittings securely to avoid the possibility of
unfiltered air entering the engine.
cC
Never operate the engine with the air filter
element removed. This will allow unfiltered
air to enter, causing rapid engine wear and
possible engine damage. Additionally, opera-
tion without the air filter element will affect
carburetor jetting with subsequent poor per-
formance and possible engine overheating.
Page 365 of 400
8-120
Engine overheating
Wait until the
engine has cooled.Check the coolant level in the
reservoir tank and/or radiator.
Level is OK.
Level is low, check the
cooling system for leakage.
No
leakage.
Leakage.Ask a Yamaha dealer
to inspect and repair
the cooling system.
Add coolant.
(See NOTE.)
Restart the engine. If the engine overheats
again, ask a Yamaha dealer to inspect and
repair the cooling system.
NOTE:
If it is difficult to get recommended coolant, tap water can be temporarily used, provided that it is
changed to the recommended coolant as soon as possible.
w
Wait for the engine and radiator to cool before removing the radiator cap. You could be burned
by hot fluid and steam blown out under pressure. Always put a thick rag over the cap when
opening. Allow any remaining pressure to escape before completely removing the cap.