TROUBLE DIAGNOSIS FOR SYSTEM BRC-37
[VDC/TCS/ABS]
C
D E
G H
I
J
K L
M A
B
BRC
Revision: 2006 December 2006 FX35/FX45
5. CHECK WHEEL SENSOR HARNESS
1. Turn ignition switch OFF and disconnect malfunctioning wheel sensor connector E46 (FR-LH), E33 (FR-RH) or B69 (RR) and
ABS actuator and electric unit (control unit) connector E56.
2. Check continuity between terminals. (Also check the continuity when steering wheel is turned right and left and when sensor
harness inside wheel well is moved.)
OK or NG
OK >> GO TO 6.
NG >> Repair or replace harness and connector that have malfunction.
6. CHECK WHEEL SENSOR
1. Replace wheel sensor that resulted in malfunction by self-diagnosis.
2. Reconnect connectors, drive vehicle at 30 km/h (19 MPH) or more for approximately 1 minute, and then perform self-diagnosis.
Is above displayed on self-diagnosis display?
OK >> Wheel sensor has malfunction.
NG >>
Replace ABS actuator and electric unit (control unit).
Perform to self-diagnosis again, and make sure that the result shows “NO DTC IS DETECTED.
FURTHER TESTING MAY BE REQUIRED”.
SFIA1186E
Power supply circuit Signal circuit Ground circuit
Wheel ABS actuator
and electric unit (control unit) Wheel sensor ABS actuator
and electric unit (control unit) Wheel sensor ABS actuator and elec-
tric unit (control unit) (signal) ABS actuator and elec-
tric unit (control unit) (ground)
Front RH 34 1 33 2 33, 34
16, 47
Front LH 45 1 46 2 45, 46
Rear RH 43 1 42 2 43, 42
Rear LH 36 3 37 4 36, 37
Power supply circuit : Continuity should exist.
Signal circuit : Continuity should exist.
Ground circuit : Continuity should not exist.
TROUBLE DIAGNOSIS FOR SYSTEM BRC-39
[VDC/TCS/ABS]
C
D E
G H
I
J
K L
M A
B
BRC
Revision: 2006 December 2006 FX35/FX45
Pressure Sensor CircuitNFS000NM
DTC C1142
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSTIC RESULTS
Check the self-diagnostic results.
Is the above displayed in the self-diagnosis display items?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK CONNECTOR
1. Disconnect pressure sensor connector and ABS actuator and electric unit (control unit) connector, check terminals for deformation, disconnection, looseness, and so on. If any malfunction is found, repair or
replace terminal.
2. Reconnect connectors and perform ABS actuator and electric unit (control unit) self-diagnosis again.
OK or NG
OK >> Connector terminal contact is loose, damaged, open or shorted.
NG >> GO TO 3.
3. CHECK PRESSURE SENSOR HARNESS
1. Turn ignition switch OFF and disconnect pressure sensor con- nector E53 and ABS actuator and electric unit (control unit) con-
nector E56.
2. Check continuity between ABS actuator and electric unit (control unit) harness connector and pressure sensor harness connec-
tor.
OK or NG
OK >> GO TO 4.
NG >> If the open or short in harness, repair or replace harness.
4. CHECK PRESSURE SENSOR
1. Connect pressure sensor connector and ABS actuator and electric unit (control unit) connector.
2. Use CONSULT-II “DATA MONITOR” to check pressure sensor value.
OK or NG
OK >> INSPECTION END
NG >> Pressure sensor is damaged or malfunctioning, replace pressure sensor.
Self-diagnostic results
PRESS SEN CIRCUIT
ABS actuator and electric unit (control unit) Pressure sensor Continuity 19 1 Ye s
20 2
18 3
SFIA1188E
Condition Data monitor display
When brake pedal is depressed. : Positive value
When brake pedal is released. : Approx. 0 bar
BRC-40
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS FOR SYSTEM
Revision: 2006 December 2006 FX35/FX45
Steering Angle Sensor CircuitNFS000NN
DTC C1143, C1156
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSTIC RESULTS
Check the self-diagnostic results.
Is the above displayed in the self-diagnosis item?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK CONNECTOR
1. Disconnect steering angle sensor connector and ABS actuator and electric unit (control unit) connector and check terminals for deformation, disconnection, looseness, and so on. If any malfunction is found,
repair or replace terminal.
2. Reconnect connectors and perform an ABS actuator and electric unit (control unit) self-diagnosis again.
OK or NG
OK >> Connector terminal contact is loose, damaged, open or shorted.
NG >> GO TO 3.
3. CHECK STEERING ANGLE SENSOR HARNESS
1. Check CAN communication circuit. Refer to BRC-50, "
CAN Communication Circuit" .
2. Turn ignition switch OFF and disconnect steering angle sensor connector M14.
3. Check continuity between steering angle sensor harness con- nector and ground.
4. Check voltage between steering angle sensor harness connec- tor and ground.
OK or NG
OK >> GO TO 4.
NG >> If the open or short in harness, repair or replace har- ness.
Self-diagnostic results
ST ANG SEN CIRCUIT
ST ANG SEN COM CIR
Steering angle sensor Ground Continuity 2—Yes
SFIA1189E
Steering angle sensor Ground Voltage
3— Battery voltage
(Approx. 12 V)
SFIA1190E
BRC-42
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS FOR SYSTEM
Revision: 2006 December 2006 FX35/FX45
3. CHECK G SENSOR HARNESS
1. Turn ignition switch OFF and disconnect G sensor connector M79 (2WD models) or M71 (AWD models) and ABS actuator
and electric unit (control unit) connector E56.
2. Check continuity between ABS actuator and electric unit (control unit) harness connector and G sensor harness connector.
OK or NG
OK >> GO TO 4.
NG >> If the open or short in harness, repair or replace harness.
4. CHECK G SENSOR
1. Connect G sensor connector and ABS actuator and electric unit (control unit) connector.
2. Use CONSULT-II “DATA MONITOR” to check if G sensor are normal.
OK or NG
OK >> Perform ABS actuator and electric unit (control unit) self-diagnosis again.
NG >> Replace malfunctioning G sensor, and then perform self-diagnosis for ABS actuator and electric
unit (control unit) again.
SFIA1192E
ABS actuator and electric unit (control unit) G sensor Continuity
63
Ye s
24 5
25 1
29 2
Vehicle status Yaw rate sensor
(Data monitor standard) Side G sensor
(Data monitor standard) Decel G sensor (AWD models)
(Data monitor standard)
When stopped − 4 to + 4 deg/s
− 1.1 to + 1.1 m/s
2− 0 . 11 t o + 0 . 11 G
Right turn Negative value Negative value —
Left turn Positive value Positive value —
Speed up — — Negative value
Speed down — — Positive value
BRC-44
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS FOR SYSTEM
Revision: 2006 December 2006 FX35/FX45
3. CHECK SOLENOID POWER AND GROUND CIRCUIT
1. Turn ignition switch OFF and disconnect ABS actuator and electric unit (control unit) connector E56.
2. Check voltage between ABS actuator and electric unit (control unit) harness connector and ground.
3. Check continuity between ABS actuator and electric unit (control unit) harness connector and ground.
OK or NG
OK >> Perform self-diagnosis again. If the same results appear, replace ABS actuator and electric unit (control
unit). Refer to BRC-58, "
ACTUATOR AND ELECTRIC
UNIT (ASSEMBLY)" .
NG >> Repair or replace harness or connectors.
Actuator Motor CircuitNFS000NQ
DTC C1111, C1140
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSTIC RESULTS (1)
Check the self-diagnostic results.
Is the above displayed in the self-diagnostic display items?
YES >> GO TO 2.
NO >> Inspection is completed.
2. CHECK SELF-DIAGNOSTIC RESULTS (2)
1. Disconnect ABS actuator and electric unit (control unit) connector. Then reconnect it securely.
2. Perform self-diagnosis again.
Do any self-diagnosis item appear?
YES >> GO TO 3.
NO >> Poor connection. Repair or replace the applicable connector.
ABS actuator and electric unit (control unit) Ground Voltage
32 — Battery voltage
(Approx. 12 V)
SFIA1196E
ABS actuator and electric unit (control unit) Ground Continuity
16, 47 — Yes
SFIA1197E
Self-diagnostic results
PUMP MOTOR
ACTUATOR RLY
TROUBLE DIAGNOSIS FOR SYSTEM BRC-45
[VDC/TCS/ABS]
C
D E
G H
I
J
K L
M A
B
BRC
Revision: 2006 December 2006 FX35/FX45
3. CHECK ABS MOTOR AND MOTOR RELAY POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF and disconnect ABS actuator and electric unit (control unit) connector E56.
2. Check voltage between ABS actuator and electric unit (control unit) harness connector and ground.
3. Check continuity between ABS actuator and electric unit (control unit) harness connector and ground.
OK or NG
OK >> Perform self-diagnosis again. If the same result appears, replace ABS actuator and electric unit (control
unit). Refer to BRC-58, "
ACTUATOR AND ELECTRIC
UNIT (ASSEMBLY)" .
NG >> Repair harness or connectors.
ABS Actuator and Electric Unit (Control Unit) Power Supply and Ground CircuitNFS000NR
DTC C1109
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSTIC RESULTS (1)
Check the self-diagnostic results.
Does
“BATTERY VOLTAGE” appear in self-diagnostic results display?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK SELF-DIAGNOSTIC RESULTS (2)
1. Disconnect ABS actuator and electric unit (control unit) connector. Then reconnect it securely.
2. Perform self-diagnosis.
Do any self-diagnosis item appear?
YES >> GO TO 3.
NO >> Poor connection. Repair or replace connector.
ABS actuator and electric unit (control unit) Ground Voltage
1, 32 — Battery voltage
(Approx. 12 V)
SFIA1198E
ABS actuator and electric unit (control unit) Ground Continuity
16, 47 — Yes
SFIA1197E
Self-diagnostic results
BATTERY VOLTAGE [ABNORMAL]
BRC-46
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS FOR SYSTEM
Revision: 2006 December 2006 FX35/FX45
3. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY CIRCUIT (1)
1. Disconnect ABS actuator and electric unit (control unit) connector E56.
2. Turn ignition switch OFF. Check voltage between ABS actuator and electric unit (control unit) harness connector and ground.
3. Turn ignition switch ON (but do not start engine). Check voltage between ABS actuator and electric unit (control unit) harness
connector and ground.
OK or NG
OK >> GO TO 4.
NG >> GO TO 5.
4. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) GROUND CIRCUIT
Check ABS actuator and electric unit (control unit) ground circuit.
OK or NG
OK >> Perform ABS actuator and electric unit (control unit) self- diagnosis again.
NG >> Repair or replace harness or connectors.
5. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY CIRCUIT (2)
1. Check fuse 10 A (terminal 4) and 30 A (terminal 32).
2. Turn ignition switch OFF and check continuity between battery positive terminal and ABS actuator and electric unit (control unit)
harness connector E56.
OK or NG
OK >> Check for non-standard conditions in battery (terminal looseness, low voltage, etc.) and alternator.
NG >>
Replace fuse 10 A or 30 A.
Open or short in harness.
ABS actuator and electric unit (control unit) Ground Voltage
32 — Battery voltage
(Approx. 12 V)
ABS actuator and electric unit (control unit) Ground Voltage 4— Battery voltage
(Approx. 12 V)
SFIA1200E
ABS actuator and electric unit (control unit) Ground Continuity
16 — Yes
SFIA1434E
ABS actuator and electric unit (control unit) Battery positive terminal Continuity
4, 32 — Yes
SFIA1435E
TROUBLE DIAGNOSIS FOR SYSTEM BRC-47
[VDC/TCS/ABS]
C
D E
G H
I
J
K L
M A
B
BRC
Revision: 2006 December 2006 FX35/FX45
Stop Lamp Switch CircuitNFS000NS
DTC C1116
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSTIC RESULTS
Check the self-diagnostic results.
Is the above displayed in the self-diagnosis display item?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK CONNECTOR
1. Disconnect stop lamp switch connector and ABS actuator and electric unit (control unit) connector E56 and check terminals for deformation, disconnection, looseness, and so on. If any malfunction is found,
repair or replace terminal.
2. Securely reconnect connectors.
3. Perform self-diagnosis again.
OK or NG
OK >> Connector terminal contact is loose, damaged, open or shorted.
NG >> GO TO 3.
3. CHECK STOP LAMP SWITCH CIRCUIT
1. Turn ignition switch OFF and disconnect stop lamp switch con- nector E210 and ABS actuator and electric unit (control unit)
connector E56.
2. Check continuity between stop lamp switch harness connector and ABS actuator and electric unit (control unit) harness con-
nector.
OK or NG
OK >> Connect connectors and perform an ABS actuator and electric unit (control unit) self-diagnosis.
NG >> Open or short in harness between stop lamp switch and ABS actuator and electric unit (control unit). Repair or replace applied harness.
Self-diagnostic results
STOP LAMP SW
ABS actuator and electric unit (control unit) Stop lamp switch Continuity 41 2 Yes
SFIA1436E