Page 46 of 425
Manipulator cover assembly
gearbox assembly (one)
reverse lock assembly nut M8
bulbrubber cover
pin 740
master control lever assembly
bulb basebush
stop plate of main rodbush
bulb jacket
N m: specified torque
Used component which can not be used any more.
Pregummed component N
m: specified torque
Used component which can not be used any more.
bush
6
oil guiding plate
location pin
steel ball 7.
938
aluminum gasket
reverse lamp switch
gearbox
selection and shifting
shaft rubber choke plug
bleed plug assembly
bush
selection and shifting block
elastic cylindrical pin 622
Page 378 of 425

Safety airbag-8
Internal failure determined by SRS-ECU
Serial
No. List of failure Description of failure
1 Micro-controller AD converter or EEPROM is faulty (the micro controller will be reset
and alarm lamp is light when the RAM has failure.)
2 Driver’s front airbag ignition loop Enable the failure
Measure the failure of loop
3 Passenger front airbag ignition loop
(if realized) Enable the failure
Measure the failure of loop
4 Seat safety belt preloaded ignition loop
(if realized) Enable the failure
Measure the failure of loop
5 Passenger side safety belt preloaded
ignition loop (if realized) Enable the failure
Measure the failure of loop
6 Driver’s side airbag ignition loop
(if realized) Enable the failure
Measure the failure of loop
7 Passenger side airbag ignition loop
(if realized ) Enable the failure
Measure the failure of loop
8 Maximum times of explosion of safet y
belt pre-tightener Reach the maximum value 6
9 Holding time of ECU ener gy
(self-supply time) Too short
10 Accelerometer Deviation range
Sensor not in constant, stable model
Sensor tests the failure itself
11 The measurement of ignition loop is
rejected continuously No cycling diagnosis test (duplicated calculation)
12 Safety sensor Calculate the safety sensor open-loop using the method that power-off
for 2 or more than 2 seconds is considered as passing
13 Initial firing current All initial firing current in normal status when the front airbag releases.
14 The ignition of side airbag is not
determined. Though SRS-ECU has received ignition information for 5 times during
HSIS cycling ignition, the ignition can not be determined due to the side
safety..
Debug the failure codes
Approach 1. The failure codes will be debugged following the ECU’s receipt from the X-431 diagnostic tester of the debugging
failure codes order through the serial interface, however, if an internal failure code is recorded or one impact is
recorded, the debugging will not be executed.
Approach 2. Ground 488# line for 5 times in 10 seconds to debug the failure codes.
Failure status display (alarm lamp keeps illuminating).
1. Bulb test
SRS-ECU will light the alarm lamp in order to test the bulb after working voltage is provided to it through the battery. The lamp
will flash for 6 times and then extinguish at 1HZ in the initial phase. The alarm lamp will keep illuminating after the working
voltage is provided in order to inform the driver’s system failures. The alarm lamp will keep illuminating for 6 seconds after the
ignition on and then be extinguished if the history-accumulated failures are less than five times. In the initial phase, SRS-ECU will
not prepare to test impact and stop release till the circuit is stable. Therefore, alarm lamp’s display manner will be one of
following projects in the initial phase. (Table 4.9).
Project 1. If the impact is recorded or the number of history accumulated failures is or more than 5,the alarm lamp will keep
illuminating, simultaneously, it will also keep illuminating if there is a possible explosion failure.
Page 380 of 425

Safety airbag-10
1. Extinguishments of safety airbag system alarm lamp
Troubleshooting
Extinguishments or normal-light of alarm lamp
NO . Troubleshooting item Description
1 T he warning la mp of safety a irbag
system is not displayed. Safety airbag system warns circuit failure
2 T he warning la mp of safety a irbag
system is light normally. Safety airbag system warns circuit failure or external
failure.
1 Extinguishments of safety airbag system alarm lamp
Test status Safety airbag system warns circuit failure.
Possible causes No voltage (fuse shutoff)
Combined instrument failure
Failure of wiring harness between instrument cluster and ECU unit
Diagnostic procedure
When first carry out failure test, joggle the wiring harness and plug to test whether there is periodical bad contact in the circuit, if
it so, please confirm whether the plug, terminal and wiring harness well connected and in good condition. If it is not any of previous
cases, operate according to the following steps.
Procedure Te s t Operation
Ye s Place the ignition switch in LOCK
position followed by next step
1 Test other wiring harness and instrument cluster
indicator lamp
·place the ignition switch in ON position
·light other alarm and indicator lamps No Test the instrument cluster power-supply
system and grounding s ystem (fuse), then
go to step 5.
Yes Next step
2 Bulb test
Warning:
Incorrect handling with the safety airbag system
units will cause the safety airbag’s improper
release and pretension of safety belt, which will
lead to serene accidents. Please read safety airbag
service warning before handling the safety airbag
units.
·Place the ignition switch in LOCK position。
·shut off accumulator negative line and keep the
status for at least 60 seconds.
·Remove the combined instrument.
Test the connection between the two
corresponding stitches of safety airbag alarm lamp No
Rep la ce th e b ulb of a larm la mp.