EVAPORATOR ASSEMBLY HEATER, AIR CONDITIONER AND VENTILATION55-90 REMOVAL SERVICE POINT <> FLEXIBLE SUCTION HOSE AND LIQUID PIPE B DISCONNECTION CAUTION As the compressor oil and receiver are highly moisture absorbent, use a non-porous material to plug the hose and nipples. To prevent the entry of dust or other foreign bodies, plug the dismantled hose and the nipples of the expansion valves. <> EVAPORATOR REMOVAL CAUTION Do not cut the upper side of the pad. 1. When removing the evaporator, cut and fold back the dashboard pad as in the diagram. (The thickness of the pad interferes with the removal of the evaporator.) 2. Remove the evaporator. INSPECTIONM1552014300938 AIR THERMO SENSOR INSPECTION Measure the resistance between connector terminals 4 and 5 under at least two different temperatures. The resistance values should generally match those in the graph. NOTE: The temperature at the check should not exceed the range in the graph. AC305312AB Dashboard pad Blower unit AC103376 Resistance Temperature (˚C) -10 01020 30 40 (kΩ) 05 10 152025 AB