2005 MITSUBISHI LANCER Motor

[x] Cancel search: Motor

Page 492 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-8
STEP 4. Check the wiring harness between C-107 
outside/inside air selection damper control motor 
connector terminal No.7 and the ignition

Page 493 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-9
Prior to the wiring harness inspection, check 
intermediate connector C-106, joint connector C-35, 
junction block connectors C-209 and C-21

Page 494 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-10
STEP 6. Check the wiring harness between C-107 
outside/inside air selection damper control motor 
connector (terminals 6 and 4) and C-139

Page 496 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-12
COMMENTS ON TROUBLE SYMPTOM
If cool air is not distributed when the A/C switch is on, 
the air thermo sensor or the A/C compressor relay 
s

Page 505 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-21
COMMENTS ON TROUBLE SYMPTOM
If cool air is not distributed when the A/C switch is on, 
the air thermo sensor or the A/C compressor relay 
s

Page 513 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-29
INSPECTION PROCEDURE 5: Blower Fan and Motor do not Turn.
FUSIBLE LINK1IGNITION
SWITCH (IG2)
BLOWER
RELAY
BLOWER 
SWITCH
BLOWER
MOTOR
Wire

Page 514 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-30
COMMENTS ON TROUBLE SYMPTOM
If the blower fan and motor does not turn when the 
blower switch is operated, the blower switch may be 
defect

Page 515 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-31
STEP 4. Check the wiring harness between C-110 
blower motor connector terminal No.2 and body 
earth.
•Check the blower motor earth line