TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-28
STEP 19. Check the magnetic clutch operation.
Refer to P.55-93.
Q: Can the sound of the magnetic clutch (click) be
heard?
YES :
Go to Step 20.
NO : Replace the compressor magnet clutch.
STEP 20. Check the refrigerant temperature
switch.
Refer to P.55-95.
Q: Is the refrigerant temperature switch operating
properly?
YES :
Go to Step 21.
NO : Replace the refrigerant temperature switch.
STEP 21. Check the air thermo sensor.
Refer to P.55-90.
Q: Is the air thermo sensor in good condition?
YES :
Go to Step 22.
NO : Replace the air thermo sensor.
STEP 22. Check the refrigerant level.
Refer to P.55-69.
Q: Is the refrigerant level correct?
YES :
Go to Step 23.
NO : Correct the refrigerant level (Refer to
On-vehicle Service P.55-70).
STEP 23. Replace the A/C-ECU.
Check that the air conditioner works normally.
Q: Is the check result normal?
YES :
This diagnosis is complete.
NO : Replace the engine-ECU or the
engine-A/T-ECU .
Page 513 of 788
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-29
INSPECTION PROCEDURE 5: Blower Fan and Motor do not Turn.
FUSIBLE LINK1IGNITION
SWITCH (IG2)
BLOWER
RELAY
BLOWER
SWITCH
BLOWER
MOTOR
Wire colour code
B : Black LG : Light green G : Green L : Blue W : White Y : Yellow SB : Sky blue
BR : Brown O : Orange GR : Gray R : Red P : Pink V : Violet
Blower Motor Circuit
Page 514 of 788

TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-30
COMMENTS ON TROUBLE SYMPTOM
If the blower fan and motor does not turn when the
blower switch is operated, the blower switch may be
defective.
TROUBLESHOOTING HINTS
•Malfunction of the blower relay
•Malfunction of the blower switch
•Damaged the wiring harness or connectors
•Malfunction of the blower motor
DIAGNOSIS
STEP 1. Check that the blower motor operates
when the blower switch is moved to the "4 (HI) "
position.
(1) Turn the ignition switch to the "ON" position.
(2) Turn the blower switch to the "4 (HI) " position.
Q: Does the blower motor operate when the blower
switch is moved to the "4 (HI) " position?
YES :
Refer to Inspection procedure 6 "Blower air
amount cannot be changed P.55-39."
NO : Go to Step 2.
STEP 2. Connector check: C-110 blower motor
connector
Q: Is the check result normal?
YES :
Go to Step 3.
NO : Repair the connector.
STEP 3. Resistance measurement at the C-110
blower motor connector.
(1) Disconnect the connector, and measure at the
wiring harness side.
(2) Measure the resistance between terminal 2 and
body earth.
OK: 2 ohms or less
Q: Is the check result normal?
YES :
Go to Step 5.
NO : Go to Step 4.
AC303804
Connector: C-110
AF
Harness side
AC303816
Connector: C-110
AK
Harness side
AC303804
Connector: C-110
AF
Harness side
AC303816
Connector: C-110
AK
Harness side
AC301541EG
Connector C-110
(Harness side)
2
1
Page 515 of 788

TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-31
STEP 4. Check the wiring harness between C-110
blower motor connector terminal No.2 and body
earth.
•Check the blower motor earth line for open
circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction P.00-5).
NO : Repair the wiring harness.
STEP 5. Voltage measurement at C-110 blower
motor connector.
(1) Disconnect the connector, and measure at the
wiring harness side.
(2) Turn the ignition switch to the "ON" position.
(3) Turn the blower switch to the "4 (HI) " position.
(4) Measure the voltage between terminal 1 and
body earth.
OK: System voltage
Q: Is the check result normal?
YES :
Go to Step 20.
NO : Go to Step 6.
AC303804
Connector: C-110
AF
Harness side
AC303816
Connector: C-110
AK
Harness side
AC303804
Connector: C-110
AF
Harness side
AC303816
Connector: C-110
AK
Harness side
AC301541CA
Connector C-110
(Harness side)
2
1
Page 516 of 788

TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-32
STEP 6. Connector check: C-214 blower relay
connector
Q: Is the check result normal?
YES :
Go to Step 7.
NO : Repair the connector.
STEP 7. Check the blower relay continuity.
Refer to P.55-75.
Q: Is the blower relay continuity in good condition?
YES :
Go to Step 8.
NO : Replace the blower relay.
STEP 8. Voltage measurement at C-214 blower
relay connector.
(1) Remove the relay, and measure at the junction
block side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal 3 and
earth.
OK: System voltage
Q: Is the check result normal?
YES :
Go to Step 10.
NO : Go to Step 9.
AC303808
Junction block side Junction block (front view)
Connector: C-214
AL
AC303822
Junction block side Junction block (front view)
Connector: C-214
AM
AC303808
Junction block side Junction block (front view)
Connector: C-214
AL
AC303822
Junction block side Junction block (front view)
Connector: C-214
AM
AC301541EI
Connector C-214
(Junction block side)
3
4
5
12