Page 564 of 788
Page 565 of 788

HEATER UNIT, HEATER CORE, BLOWER ASSEMBLY AND EVAPORATOR UNIT
HEATER, AIR CONDITIONER AND VENTILATION55-81
HEATER UNIT, HEATER CORE, BLOWER ASSEMBLY
AND EVAPORATOR UNIT
REMOVAL AND INSTALLATION
M1552011600457
Pre-removal and Post-installation Operation
•Refrigerant draining and Refilling (Refer to Charging
P.55-70 and Discharging P.55-72).
•Engine coolant Draining and Refilling (Refer to GROUP
14, On vehicles service P.14-22).
•Instrument Panel Removal and Installation (Refer to
GROUP 52A, Instrument Panel P.52A-2).
•Air cleaner cover and air flow sensor assembly Removal
and Installation (Refer to GROUP 15, Air cleaner P.15-3).
•Rear console assembly Removal and Installation (Refer
to GROUP 52A, Rear console assembly P.52A-8).
•Front floor console assembly Removal and Installation
(Refer to GROUP 52A, Front floor console assembly
P.52A-6).
•Front seat assembly Removal and Installation (Refer to
GROUP 52A, Front seat assembly P.52A-24).
AC304861
1
2
3
4 5
6
7
8
N
9
AB
12 ± 2 N·m
6, 7O ring -Pipe coupling
A/C compressor oil:
SUN PAG 56
44 ± 10 N·m
44 ± 10 N·m
Removal steps
1. Front deck crossmember
2. Centre duct
3. Intake duct
•Foot duct (RH), Rear heater duct A
(RH) upper side (Refer to
P.55-101.)4. Blower assembly
5. Heater hose connection
<>6. Flexible suction hose connection
<>7. Liquid pipe B connection
8. O ring
9. Heater unitRemoval steps (Continued)
Page 566 of 788
Page 567 of 788
HEATER UNIT, HEATER CORE, BLOWER ASSEMBLY AND EVAPORATOR UNIT
HEATER, AIR CONDITIONER AND VENTILATION55-83
DISASSEMBLY AND ASSEMBLY M1551005400235
AC304863
1
2
3
4
5
N
6
7
8
9
AB
6O ring -Pipe coupling
A/C compressor oil:
SUN PAG 56
Disassembly steps
1. Foot duct (RH)
2. Heater core
3. Expansion valve
4. O ring
5. Evaporator cover6. Evaporator
7. Air thermo sensor clip
8. Air thermo sensor
9. Heater caseDisassembly steps (Continued)
Page 568 of 788
HEATER UNIT, HEATER CORE, BLOWER ASSEMBLY AND EVAPORATOR UNIT
HEATER, AIR CONDITIONER AND VENTILATION55-84
BLOWER ASSEMBLY
DISASSEMBLY AND REASSEMBLYM1551005500179
AC3054131AB
3
4
57
6
12
Disassembly steps
1. Joint duct
2. Resister
3. Outside/inside air selection damper
control motor
4. Hose5. Blower motor
6. Air filter
7. Blower caseDisassembly steps (Continued)
Page 569 of 788
Page 570 of 788
Page 571 of 788
BLOWERMOTOR, RESISTOR AND OUTSIDE/ INSIDE AIR SELECTION DAMPER CONTROL MOTOR
HEATER, AIR CONDITIONER AND VENTILATION55-87
OUTSIDE/INSIDE AIR SELECTION
DAMPER CONTROL MOTOR CHECK
CAUTION
Cut off the battery voltage when the damper is in
the inside/outside air position.
Lever position Battery
connectionLever
operation
At the inside
position•Connect
terminal 7 to
the positive
battery
terminal
•Connect
terminal 4 to
the negative
battery
terminalThe lever
moves from the
inside position
to the outside
position
At the outside
position•Connect
terminal 7 to
the positive
battery
terminal
•Connect
terminal 6 to
the negative
battery
terminalThe lever
moves from the
outside position
to the inside
position
AC100625
Inside air
Outside air
AE