Page 1120 of 3419

COMBINATION METERS
DI-17
C
D
E
F
G
H
I
J
L
MA
B
DI
Revision: October 20052005 QX56
How to Proceed With Trouble DiagnosisEKS00BC1
1. Confirm the symptom or customer complaint.
2. Perform diagnosis according to diagnosis flow. Refer to DI-17, "
Diagnosis Flow" .
3. According to the symptom chart, repair or replace the cause of the symptom.
4. Does the meter operate normally? If so, go to 5. If not, go to 2.
5. Inspection End.
Diagnosis FlowEKS00BC2
1. CHECK WARNING INDICATOR ILLUMINATION
1. Turn ignition switch ON.
2. Make sure warning indicators (such as malfunction indicator lamp and oil pressure low/coolant tempera-
ture high warning indicator) illuminate.
Do warning indicators illuminate?
YES >> GO TO 2.
NO >> Check ignition power supply system of combination meter. Refer to DI-18, "
Power Supply and
Ground Circuit Inspection" .
2. CHECK SELF-DIAGNOSIS OPERATION OF COMBINATION METER
Perform combination meter self-diagnosis. Refer to DI-13, "
SELF-DIAGNOSIS FUNCTION" .
Does self-diagnosis function operate?
YES >> GO TO 3.
NO >> Check combination meter power supply and ground circuit. Refer to DI-18, "
Power Supply and
Ground Circuit Inspection" .
3. CHECK ODOMETER OPERATION
Check segment display status of odometer.
Is the display normal?
YES >> GO TO 4.
NO >> Replace the combination meter. Refer to IP-13, "
Combi-
nation Meter" .
4. CHECK COMBINATION METER CIRCUIT
Check indication of each meter/gauge in self-diagnosis mode.
OK or NG
OK >> Go to DI-19, "Symptom Chart" .
NG >> Replace the combination meter. Refer to IP-13, "
Combi-
nation Meter" .
WKIA1531E
WKIA1814E
Page 1122 of 3419

COMBINATION METERS
DI-19
C
D
E
F
G
H
I
J
L
MA
B
DI
Revision: October 20052005 QX56
Symptom ChartEKS00BC4
Vehicle Speed Signal InspectionEKS00BC5
1. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) SELF-DIAGNOSIS
Refer to BRC-29, "
SELF-DIAGNOSIS" .
OK or NG
OK >> Replace the combination meter. Refer to IP-13, "Combination Meter" .
NG >> Perform the "Diagnostic Procedure" for displayed DTC. Refer to BRC-11, "
TROUBLE DIAGNO-
SIS" .
Engine Oil Pressure Signal Inspection EKS00BC6
1. CHECK OIL PRESSURE SENSOR SIGNAL
1. Turn ignition switch ON.
2. Check voltage between combination meter harness connector
M24 terminal 20 (Y) and ground.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
Trouble phenomenon Possible cause
Improper tachometer indication. Refer to DI-21, "
Engine Speed Signal Inspection" .
Improper water temperature gauge indication. Refer to DI-21, "
Water Temperature Signal Inspection" .
Improper speedometer or odometer. Refer to DI-19, "
Vehicle Speed Signal Inspection" .
Improper fuel gauge indication.
Refer to DI-22, "
Fuel Level Sensor Unit Inspection" .
Fuel warning lamp indication is irregular.
Improper A/T oil temperature gauge indicationRefer to AT-126, "
DTC P1710 A/T FLUID TEMPERATURE SEN-
SOR CIRCUIT" .
Improper voltage gauge indication
Replace combination meter. Refer to IP-13, "
Combination Meter"
.
More than one gauge does not give proper indication.
Improper A/T position indication. Refer to DI-40, "
A/T INDICATOR" .
Illumination control does not operate properly. Refer to LT-152, "
ILLUMINATION" .
Te r m i n a l s
Condition Voltage (V) (+)
(–)
ConnectorTe r m i n a l
(Wire color)
M24 20 (Y) GroundWhen ignition switch is in ON
position. (Engine stopped)Ye s
Engine running. (Idle speed) Yes
WKIA1833E
Page 1123 of 3419

DI-20
COMBINATION METERS
Revision: October 20052005 QX56
2. CHECK OIL PRESSURE SENSOR GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect combination meter connector M24 and oil pressure
sensor connector F4.
3. Check continuity between combination meter harness connector
M24 terminal 16 (B/P) and oil pressure sensor harness connec-
tor F4 terminal 3 (B/P).
OK or NG
OK >> Replace the combination meter. Refer to IP-13, "Combi-
nation Meter" .
NG >> Repair harness or connector.
3. CHECK OIL PRESSURE SENSOR REFERENCE VOLTAGE
1. Turn ignition switch OFF.
2. Disconnect oil pressure sensor connector F4.
3. Turn ignition switch ON.
4. Check voltage between combination meter harness connector
M24 terminal 22 (GR/L) and ground.
OK or NG
OK >> GO TO 4.
NG >> Replace the combination meter. Refer to IP-13, "
Combi-
nation Meter" .
4. CHECK OIL PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect combination meter connector M24.
3. Check continuity between combination meter harness connector M24 terminal 22 (GR/L) and oil pressure
sensor harness connector F4 terminal 1 (GR/L).
4. Check continuity between combination meter harness connector
M24 terminal 22 (GR/L) and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.Continuity should exist.
WKIA1837E
Voltage : Approx. 5V
WKIA1834E
Continuity should exist.
Continuity should not exist.
WKIA1835E
Page 1124 of 3419

COMBINATION METERS
DI-21
C
D
E
F
G
H
I
J
L
MA
B
DI
Revision: October 20052005 QX56
5. CHECK OIL PRESSURE SENSOR SIGNAL CIRCUIT
1. Check continuity between combination meter harness connector M24 terminal 20 (Y) and oil pressure
sensor harness connector F4 terminal 2 (Y).
2. Check continuity between combination meter harness connector
M24 terminal 20 (Y) and ground.
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.
6. CHECK OIL PRESSURE SENSOR GROUND CIRCUIT
Check continuity between combination meter harness connector
M24 terminal 16 (B/P) and ground.
OK or NG
OK >> Replace oil pressure sensor.
NG >> Repair harness or connector.
Water Temperature Signal Inspection EKS00BC7
1. CHECK ECM SELF-DIAGNOSIS
Perform ECM self-diagnosis. Refer to EC-130, "
SELF-DIAG RESULTS MODE" .
OK or NG
OK >> Replace the combination meter. Refer to IP-13, "Combination Meter" .
NG >> Perform "Diagnostic procedure" for displayed DTC. Refer to EC-95, "
TROUBLE DIAGNOSIS" .
Engine Speed Signal Inspection EKS00BC8
1. CHECK ECM SELF-DIAGNOSIS
Perform ECM self-diagnosis. Refer to EC-130, "
SELF-DIAG RESULTS MODE" .
OK or NG
OK >> Replace the combination meter. Refer to IP-13, "Combination Meter" .
NG >> Perform "Diagnostic procedure" for displayed DTC. Refer to EC-95, "
TROUBLE DIAGNOSIS" . Continuity should exist.
Continuity should not exist.
WKIA1836E
Continuity should not exist.
WKIA2685E
Page 1140 of 3419

WARNING LAMPS
DI-37
C
D
E
F
G
H
I
J
L
MA
B
DI
Revision: October 20052005 QX56
Oil Pressure Warning Lamp Stays Off (Ignition Switch ON)EKS00BCK
1. CHECK OIL PRESSURE SENSOR SIGNAL
1. Turn ignition switch ON.
2. Check voltage between combination meter harness connector
M24 terminal 20 (Y) and ground.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. CHECK OIL PRESSURE SENSOR GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect combination meter connector M24 and oil pressure
sensor connector F4.
3. Check continuity between combination meter harness connector
M24 terminal 16 (B/P) and oil pressure sensor harness connec-
tor F4 terminal 3 (B/P).
OK or NG
OK >> Replace the combination meter. Refer to IP-13, "Combi-
nation Meter" .
NG >> Repair harness or connector.
3. CHECK OIL PRESSURE SENSOR REFERENCE VOLTAGE
1. Turn ignition switch OFF.
2. Disconnect oil pressure sensor connector F4.
3. Turn ignition switch ON.
4. Check voltage between combination meter harness connector
M24 terminal 22 (GR/L) and ground.
OK or NG
OK >> GO TO 4.
NG >> Replace the combination meter. Refer to IP-13, "
Combi-
nation Meter" .
Te r m i n a l s
Condition Voltage (V) (+)
(–)
ConnectorTe r m i n a l
(Wire color)
M24 20 (Y) GroundWhen ignition switch is in ON
position. (Engine stopped)Ye s
Engine running. (Idle speed) Yes
WKIA1833E
Continuity should exist.
WKIA1837E
Voltage : Approx. 5V
WKIA1834E
Page 1141 of 3419

DI-38
WARNING LAMPS
Revision: October 20052005 QX56
4. CHECK OIL PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect combination meter connector M24.
3. Check continuity between combination meter harness connector M24 terminal 22 (GR/L) and oil pressure
sensor harness connector F4 terminal 1 (GR/L).
4. Check continuity between combination meter harness connector
M24 terminal 22 (GR/L) and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
5. CHECK OIL PRESSURE SENSOR SIGNAL CIRCUIT
1. Check continuity between combination meter harness connector M24 terminal 20 (Y) and oil pressure
sensor harness connector F4 terminal 2 (Y).
2. Check continuity between combination meter harness connector
M24 terminal 20 (Y) and ground.
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.
6. CHECK OIL PRESSURE SENSOR GROUND CIRCUIT
Check continuity between combination meter harness connector
M24 terminal 16 (B/P) and ground.
OK or NG
OK >> Replace oil pressure sensor.
NG >> Repair harness or connector.Continuity should exist.
Continuity should not exist.
WKIA1835E
Continuity should exist.
Continuity should not exist.
WKIA1836E
Continuity should not exist.
WKIA2685E
Page 1142 of 3419
WARNING LAMPS
DI-39
C
D
E
F
G
H
I
J
L
MA
B
DI
Revision: October 20052005 QX56
Oil Pressure Warning Lamp Does Not Turn Off (Oil Pressure Is Normal)EKS00BCL
NOTE:
For oil pressure inspection, refer to LU-7, "
OIL PRESSURE CHECK" .
1. CHECK ENGINE OIL PRESSURE GAUGE OPERATION
Observe operation of engine oil pressure gauge.
Does engine oil pressure gauge function properly?
YES >> Replace the combination meter. Refer to IP-13, "Combination Meter" .
NO >> Go to DI-19, "
Engine Oil Pressure Signal Inspection" .
Page 1268 of 3419
BASIC SERVICE PROCEDURE
EC-77
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
Idle Speed and Ignition Timing CheckUBS00KZV
IDLE SPEED
With CONSULT-II
Check idle speed in “DATA MONITOR” mode with CONSULT-II.
With GST
Check idle speed with GST.
IGNITION TIMING
Any of following two methods may be used.
Method A
1. Attach timing light to loop wire as shown.
2. Check ignition timing.
Method B
1. Remove ignition coil No.1.
SEF 0 58 Y
BBIA0377E
BBIA0379E
BBIA0360E