2005 INFINITI QX4 air condition

[x] Cancel search: air condition

Page 1436 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0172, P0175 FUEL INJECTION SYSTEM FUNCTION
EC-245
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
DTC P0172, P0175 FUEL INJECTION SYSTEM FUNCTIONPFP:16600
On Board Diagnosis LogicUBS00L

Page 1437 of 3419

INFINITI QX4 2005  Factory Service Manual EC-246Revision: October 2005
DTC P0172, P0175 FUEL INJECTION SYSTEM FUNCTION
2005 QX56
If engine starts, go to EC-249, "Diagnostic Procedure" . If engine does not start, remove spark plugs and
check f

Page 1444 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0181 FTT SENSOR
EC-253
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
DTC P0181 FTT SENSORPFP:22630
Component DescriptionUBS00H34
The fuel tank temperature sensor is used to detect the

Page 1458 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0222, P0223 TP SENSOR
EC-267
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not u

Page 1462 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0300 - P0308 MULTIPLE CYLINDER MISFIRE, NO. 1 - 8 CYLINDER MIS-
FIRE
EC-271
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
DTC P0300 - P0308 MULTIPLE CYLINDER MISFIRE, NO. 1 - 8 CYLIND

Page 1463 of 3419

INFINITI QX4 2005  Factory Service Manual EC-272Revision: October 2005
DTC P0300 - P0308 MULTIPLE CYLINDER MISFIRE, NO. 1 - 8 CYLINDER MIS-
FIRE
2005 QX56
 WITH CONSULT-II
1. Turn ignition switch ON, and select “DATA MONITOR” mode
with CO

Page 1472 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0327, P0328, P0332, P0333 KS
EC-281
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
D

Page 1478 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0335 CKP SENSOR (POS)
EC-287
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is m