Revision: October 20052005 QX56
Hazard reminder does not activate properly when
pressing lock or unlock button of keyfob.
(Horn reminder OK)1. Check hazard reminder mode with CONSULT-II
NOTE:
Hazard reminder mode can be changed.
First check the hazard reminder mode setting.BL-57
2. Check hazard function with hazard switch —
3. Replace BCM.BCS-20
Horn reminder does not activate properly when
pressing lock or unlock button of keyfob.
(Hazard reminder OK)1. Check horn reminder mode with CONSULT-II
NOTE:
Horn reminder mode can be changed.
First check the horn reminder mode setting.BL-57
2. Check horn function with horn switch —
3. IPDM E/R operation checkBL-68
4. Replace BCM.BCS-20
Back door open/close operation is not carried out
with keyfob operation.
(The automatic back door system is normal.)1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Key switch (insert) checkBL-62
3. Check that glass hatch is closed —
4. Remote keyless entry receiver systemBL-66
5. Replace BCM.BCS-20
Room lamp, ignition keyhole illumination and step
lamp operation do not activate properly.1. Room lamp operation checkBL-70
2. Ignition keyhole illumination operation checkBL-70
3.Step lamp operation checkLT- 1 3 0
4. Door switch checkBL-63
5. Replace BCM.BCS-20
Panic alarm (horn and headlamp) does not activate
when panic alarm button is continuously pressed.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Key switch and key lock solenoid (insert) checkBL-62
3. Replace BCM.BCS-20
Auto door lock operation does not activate properly.
(All other remote keyless entry functions OK.)1. Check auto door lock operation mode with CONSULT-II
NOTE:
Auto door lock operation mode can be changed.
First check the auto door lock operation mode setting.BL-57
2. Replace BCM.BCS-20
Keyless power window down (open) operation does
not activate properly.
(All other remote keyless entry functions OK.)1. Check power window down operation mode with CONSULT-II
NOTE:
Power window down operation mode can be changed.
First check the power window down operation mode setting.BL-57
2. Check power window function with switch —
3. Replace BCM.BCS-20
Symptom Diagnoses/service procedureReference
page
Page 832 of 3419
REMOTE KEYLESS ENTRY SYSTEM
BL-65
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
4. CHECK BACK DOOR SWITCH GROUND
Check continuity between back door latch connector terminal 8 and
ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Keyfob Battery and Function CheckEIS008QB
1. CHECK KEYFOB BATTERY
Remove battery and measure voltage across battery positive and negative terminals, (+) and (−).
NOTE:
Keyfob does not function if battery is not set correctly.
OK or NG
OK >> GO TO 2.
NG >> Replace battery.8 - Ground : Continuity should exist.
LIIA0828E
Voltage : 2.5V - 3.0V
SEL237W
Page 833 of 3419

BL-66
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
2. CHECK KEYFOB FUNCTION
With CONSULT-II
Check keyfob function in “DATA MONITOR” mode with CONSULT-II.
When pushing each button of keyfob, the corresponding monitor item should
be turned as follows.
Without CONSULT-II
Check keyfob function using Remote Keyless Entry Tester J-43241.
OK or NG
OK >> WITH CONSULT-II: Keyfob, remote keyless entry receiver and wiring harness between BCM and
remote keyless entry receiver are OK. Replace BCM. Refer to BCS-20, "
Removal and Installation
of BCM" .
OK >> WITHOUT CONSULT-II: Keyfob is OK. Further inspection is necessary. Refer to BL-60, "
SYMP-
TOM CHART" .
NG >> WITH CONSULT-II: Further inspection is necessary. Refer to BL-60, "
SYMPTOM CHART" .
NG >> WITHOUT CONSULT-II: Replace keyfob. Refer to BL-71, "
ID Code Entry Procedure" .
Remote Keyless Entry Receiver System CheckEIS008QC
1. REMOTE KEYLESS ENTRY RECEIVER SIGNAL
Check signal voltage waveform between BCM connector M18 termi-
nal 20 and ground using an oscilloscope.
OK or NG
OK >> Remote keyless entry receiver signal power supply, ground and signal circuits are OK. Replace
BCM. Refer to BCS-20, "
Removal and Installation of BCM" .
NG >> GO TO 2.Condition Monitor item
Pushing LOCK KEYLESS LOCK : ON
Pushing UNLOCK KEYLESS UNLOCK : ON
Keep pushing UNLOCKRKE KEEP UNLK
turns to ON 3 seconds
after UNLOCK button
is pushed.
Pushing PANIC KEYLESS PANIC : ON
Pushing LOCK and UNLOCK
at the same timeRKE LCK-UNLCK : ON
Pushing Power Back Door KEYLESS PBD : ON
LIIA1487E
Condition:
Keyfob buttons released : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .
Keyfob buttons pressed : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .LIIA1275E
Page 838 of 3419

REMOTE KEYLESS ENTRY SYSTEM
BL-71
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
ID Code Entry ProcedureEIS008QJ
KEYFOB ID SET UP WITH CONSULT-II
NOTE:
If a keyfob is lost, the ID code of the lost keyfob must be erased to prevent unauthorized use. A
specific ID code can be erased with CONSULT-II. However, when the ID code of a lost keyfob is not
known, all controller ID codes should be erased. After all ID codes are erased, the ID codes of all
remaining and/or new keyfobs must be re-registered.
When registering an additional keyfob, the existing ID codes in memory may or may not be erased.
If five ID codes are stored in memory when an additional code is registered, only the oldest code is
erased. If less than five codes are stored in memory when an additional code is registered, the
new ID code is added and no ID codes are erased.
Entry of a maximum of five ID codes is allowed. When more than five codes are entered, the oldest
ID code will be erased.
Even if the same ID code that is already in memory is input, the same ID code can be entered. The
code is counted as an additional code.
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carries out CAN communication.
1. Turn ignition switch OFF.
2. Connect CONSULT-II and CONSULT-II CONVERTER to the
data link connector.
3. Turn ignition switch ON.
4. Touch “START (NISSAN BASED VHCL)”.
5. Touch “BCM”.
If "BCM" is not indicated, refer to GI-39, "
CONSULT-II Data Link
Connector (DLC) Circuit" .
BBIA0336E
BCIA0029E
BCIA0030E
Page 839 of 3419
BL-72
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
6. Touch “MULTI REMOTE ENT”.
7. Touch “WORK SUPPORT”.
8. The items are shown on the figure can be set up.
“REMO CONT ID REGIST”
Use this mode to register a keyfob ID code.
NOTE:
Register the ID code when keyfob or BCM is replaced, or
when additional keyfob is required.
“REMO CONT ID ERASUR”
Use this mode to erase a keyfob ID code.
“REMO CONT ID CONFIR”
Use this mode to confirm if a keyfob ID code is registered or
not.
LIIA0194E
BCIA0031E
LIIA1147E
Page 840 of 3419
REMOTE KEYLESS ENTRY SYSTEM
BL-73
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
KEYFOB ID SET UP WITHOUT CONSULT-II
LIIA1670E
Page 841 of 3419

BL-74
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
NOTE:
If a keyfob is lost, the ID code of the lost keyfob must be erased to prevent unauthorized use. A specific ID
code can be erased with CONSULT-II. However, when the ID code of a lost keyfob is not known, all con-
troller ID codes should be erased. After all ID codes are erased, the ID codes of all remaining and/or new
keyfobs must be re-registered.
To erase all ID codes in memory, register one ID code (keyfob) five times. After all ID codes are erased,
the ID codes of all remaining and/or new keyfobs must be re-registered.
When registering an additional keyfob, the existing ID codes in memory may or may not be erased. If five
ID codes are stored in memory, when an additional code is registered, only the oldest code is erased. If
less than five ID codes are stored in memory, when an additional ID code is registered, the new ID code is
added and no ID codes are erased.
If you need to activate more than two additional new keyfobs, repeat the procedure “Additional ID code
entry” for each new keyfob.
Entry of maximum five ID codes is allowed. When more than five ID codes are entered, the oldest ID code
will be erased.
Even if same ID code that is already in the memory is input, the same ID code can be entered. The code
is counted as an additional code.
Keyfob Battery ReplacementEIS008QK
LIIA1514E
Page 843 of 3419

BL-76
VEHICLE SECURITY (THEFT WARNING) SYSTEM
Revision: October 20052005 QX56
System DescriptionEIS008QM
DESCRIPTION
Operation Flow
Setting the vehicle security system
Initial condition
Ignition switch is in OFF position.
Disarmed phase
When the vehicle is being driven or when doors or glass hatch is open, the vehicle security system is set
in the disarmed phase on the assumption that the owner is inside or near the vehicle.
Pre-armed phase and armed phase
The vehicle security system turns into the "pre-armed" phase when hood, glass hatch and all doors are
closed and locked by keyfob. The security indicator lamp illuminates for 30 seconds, then the system
automatically shifts into the "armed" phase.
Canceling the set vehicle security system
When one of the following operations is performed, the armed phase is canceled.
1. Unlock the doors with the key or the keyfob.
2. Open the power back door with the keyfob. When the power back door is closed after opening the power
back door with the keyfob, the system returns to the armed phase.
Activating the alarm operation of the vehicle security system
Make sure the system is in the armed phase.
When one of the following operations is performed, the system sounds the horns and flashes the headlamps
for about 50 seconds.
1. Engine hood, glass hatch or any door is opened before unlocking door with key or keyfob.
7. BCM M18, M19, M20
(view with instrument panel LH
removed)8. Horn E3 9. Front door lock assembly LH (key
cylinder switch) D14
10. Main power window and door lock/
unlock switch D7, D8
Power window and door lock/unlock
switch RH D10511. Front door switch
LH B8
RH B10812. Rear door switch
LH B18
RH B116
13. Back door latch (door ajar switch) D503
Glass hatch ajar switch D70714. Combination meter M24 15. Hood switch E8
16. RH headlamp
PIIA1367E