Page 486 of 3419

TROUBLE DIAGNOSIS
ATC-91
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: October 20052005 QX56
8. CHECK PBR REFERENCE VOLTAGE AND GROUND CIRCUITS
1. Turn ignition switch OFF.
2. Disconnect the front air control harness connector.
3. Check continuity between front air control harness connector
M49 terminal 2 and terminal 15.
OK or NG
OK >> GO TO 10.
NG >> GO TO 9.
9. CHECK PBR REFERENCE VOLTAGE CIRCUIT FOR OPEN
1. Disconnect the defroster door motor harness connector.
2. Check continuity between defroster door motor harness connec-
tor M144 (B) terminal 3, 2 and front air control harness connec-
tor M49 (A) terminal 2, 15.
OK or NG
OK >> Replace defroster door motor. Refer to ATC-163,
"Removal and Installation" .
NG >> Repair or replace harness as necessary.
10. CHECK PBR FEEDBACK VOLTAGE
1. Reconnect the front air control harness connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M49
terminal 25 and ground while cycling defroster switch on and off.
OK or NG
OK >> GO TO 12.
NG >> GO TO 11.
11 . CHECK PBR FEEDBACK SIGNAL CIRCUIT FOR SHORT TO GROUND
1. Turn ignition switch OFF.
2. Disconnect front air control harness connector.
3. Check continuity between front air control harness connector
M49 terminal 25 and ground.
OK or NG
OK >> Replace front air control. Refer to ATC-147, "FRONT
AIR CONTROL" .
NG >> Repair or replace harness as necessary.Continuity should exist.
WJIA1731E
2 - 3 : Continuity should exist.
15 - 2 : Continuity should exist.
WJIA1777E
Voltage : Approx. 1V - 4.5V
WJIA1786E
Continuity should not exist.
WJIA1787E
Page 487 of 3419
ATC-92
TROUBLE DIAGNOSIS
Revision: October 20052005 QX56
12. CHECK PBR FEEDBACK CIRCUIT FOR OPEN
1. Turn ignition switch OFF.
2. Disconnect the defroster door motor harness connector and
front air control harness connector.
3. Check continuity between defroster door motor harness connec-
tor M144 terminal 4 and front air control harness connector M49
terminal 25
OK or NG
OK >> Replace defroster door motor. Refer to ATC-163,
"Removal and Installation" .
NG >> Repair or replace harness as necessary.Continuity should exist.WJIA0558E
Page 491 of 3419
![INFINITI QX4 2005 Factory Service Manual ATC-96
TROUBLE DIAGNOSIS
Revision: October 20052005 QX56
1. CHECK FUSES
Check 20A fuses [No. 24 and 27 (Located in the fuse and fusible link box)]. For fuse layout. Refer to PG-77,
"FUSE AND FUSIBLE L INFINITI QX4 2005 Factory Service Manual ATC-96
TROUBLE DIAGNOSIS
Revision: October 20052005 QX56
1. CHECK FUSES
Check 20A fuses [No. 24 and 27 (Located in the fuse and fusible link box)]. For fuse layout. Refer to PG-77,
"FUSE AND FUSIBLE L](/manual-img/42/57035/w960_57035-490.png)
ATC-96
TROUBLE DIAGNOSIS
Revision: October 20052005 QX56
1. CHECK FUSES
Check 20A fuses [No. 24 and 27 (Located in the fuse and fusible link box)]. For fuse layout. Refer to PG-77,
"FUSE AND FUSIBLE LINK BOX" .
OK or NG
OK >> GO TO 2.
NG >> GO TO 10.
2. CHECK FRONT BLOWER MOTOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front blower motor connector.
3. Turn ignition switch ON.
4. Press the mode switch to select any mode except off.
5. Turn the front blower control dial to high.
6. Check voltage between front blower motor harness connector
M62 terminal 2 (W/L) and ground.
OK or NG
OK >> GO TO 12.
NG >> GO TO 3.
3. CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front blower motor relay.
3. Turn ignition switch ON.
4. Check voltage between front blower motor relay harness con-
nector M107 terminals 5 (G/R) and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.
4. CHECK FRONT BLOWER MOTOR RELAY
Turn ignition switch OFF.
Refer to ATC-100, "
Front Blower Motor Relay" .
OK or NG
OK >> GO TO 5.
NG >> Replace front blower motor relay.Fuses are good.
2 - Ground : Battery voltage.
WJIA1331E
5 - Ground : Battery voltage.
WJIA1359E
Page 492 of 3419

TROUBLE DIAGNOSIS
ATC-97
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: October 20052005 QX56
5. CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) CIRCUIT FOR OPEN
Check continuity between front blower motor relay harness connec-
tor M107 terminal 3 (W/L) and front blower motor harness connector
M62 terminal 2 (W/L).
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.
6. CHECK VARIABLE BLOWER CONTROL POWER SUPPLY CIRCUIT FOR OPEN
1. Disconnect variable blower control harness connector.
2. Check continuity between front blower motor relay harness con-
nector M107 terminals 3 (W/L) and variable blower control har-
ness connector M122 terminal 1 (W/L).
OK or NG
OK >> GO TO 7.
NG >> Repair harness or connector.
7. CHECK VARIABLE BLOWER CONTROL SIGNAL CIRCUIT
1. Disconnect front air control connector.
2. Check continuity between front air control harness connector
M49 terminal 13 (G/R) and variable blower control harness con-
nector M122 terminal 2 (G/R).
OK or NG
OK >> GO TO 8.
NG >> Repair harness or connector.
8. CHECK FRONT BLOWER MOTOR RELAY (COIL SIDE) POWER SUPPLY
1. Turn ignition switch ON.
2. Check voltage between front blower motor relay harness con-
nector M107 terminal 2 (Y/G) and ground.
OK or NG
OK >> GO TO 9.
NG >> Repair harness or connector.3 - 2 : Continuity should exist.
WJIA1360E
3 - 1 : Continuity should exist.
WJIA1361E
13 - 2 : Continuity should exist.
WJIA1362E
2 - Ground : Battery voltage.
WJIA1363E
Page 493 of 3419

ATC-98
TROUBLE DIAGNOSIS
Revision: October 20052005 QX56
9. CHECK FRONT BLOWER MOTOR RELAY (COIL SIDE) GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between front blower motor relay connector
M107 terminal 1 (R/B) and front air control harness connector
M49 terminal 26 (R/B).
OK or NG
OK >> Replace front air control. Refer to ATC-147, "FRONT
AIR CONTROL" .
NG >> Repair harness or connector.
10. REPLACE FUSES
1. Replace fuses.
2. Activate the front blower motor.
3. Do fuses blow?
YES or NO
YES >> GO TO 11.
NO >> Inspection End.
11 . CHECK FRONT BLOWER MOTOR POWER SUPPLY CIRCUIT FOR SHORT
1. Turn ignition switch OFF.
2. Disconnect front blower motor connector and variable blower
control connector.
3. Check continuity between variable blower control harness con-
nector M122 terminal 1 (W/L) and ground.
OK or NG
OK >> GO TO 12.
NG >> Repair harness or connector.
12. CHECK VARIABLE BLOWER CONTROL SIGNAL CIRCUIT
1. Disconnect front air control connector.
2. Check continuity between front air control harness connector
M49 terminal 13 (G/R) and variable blower control harness con-
nector M122 terminal 2 (G/R).
OK or NG
OK >> GO TO 13.
NG >> Repair harness or connector.
13. CHECK FRONT BLOWER MOTOR
Refer to ATC-100, "
Front Blower Motor" .
OK or NG
OK >> GO TO 14.
NG >> Replace front blower motor.1 - 26 : Continuity should exist.
WJIA1364E
1 - Ground. : Continuity should not exist.
WJIA1365E
13 - 2 : Continuity should exist.
WJIA1366E
Page 498 of 3419
TROUBLE DIAGNOSIS
ATC-103
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: October 20052005 QX56
3. CHECK REAR AIR CONTROL
Refer to ATC-102, "
Rear Blower Switch (Rear) Circuit" .
OK or NG
OK >> GO TO 4.
NG >> Replace rear blower switch (rear). Refer to ATC-147, "
REAR AIR CONTROL" .
4. CHECK CIRCUIT CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect rear blower switch (front) connector and rear air con-
trol connector.
3. Check continuity between rear blower switch (front) harness
connector M52 terminal 2 (BR) and rear blower switch (rear)
harness connector R208 terminal 10 (BR).
OK or NG
OK >> Inspection End.
NG >> Repair harness or connector.2 - 10 : Continuity should exist.WJIA1281E
Page 500 of 3419

TROUBLE DIAGNOSIS
ATC-105
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: October 20052005 QX56
1. DIAGNOSTIC PROCEDURE
Blower motor rotates normally at each speed.
OK or NG
OK >> Inspection End.
NG >> 1. Does not rotate at any speed, GO TO 2.
2. Does not rotate at 1 - 3 speed, GO TO 13.
3. Does not rotate at 4 speed, GO TO 18.
2. CHECK FUSES
Check 15A fuses [Nos. 10 and 11, located in the fuse block (J/B)]. Refer to PG-76, "
FUSE BLOCK-JUNCTION
BOX(J/B)" .
OK or NG
OK >> GO TO 3.
NG >> GO TO 8.
3. CHECK REAR BLOWER MOTOR POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect rear blower motor connector.
3. Select any rear blower speed except OFF.
4. Turn ignition switch ON.
5. Check voltage between rear blower motor harness connector
B134 terminal 2 (L/R) and ground.
OK or NG
OK >> GO TO 11.
NG >> GO TO 4.
4. CHECK REAR BLOWER MOTOR RELAY
Turn ignition switch OFF.
Refer to AT C - 11 0 , "
Rear Blower Motor Relay" .
OK or NG
OK >> GO TO 5.
NG >> Replace rear blower motor relay.
5. CHECK REAR BLOWER MOTOR POWER FROM RELAY TO REAR BLOWER MOTOR
1. Reconnect rear blower motor connector.
2. Disconnect rear blower motor relay J-1.
3. Turn ignition switch ON.
4. Set rear blower switch (front) to any position except OFF, REAR,
or 4 - speed.
5. Momentarily (no more than 4 seconds), connect a jumper wire
between rear blower motor relay connector J-1 (harness side)
terminals 3 and 5.
OK or NG
OK >> GO TO 6.
NG >> GO TO 10.2 - Ground : Battery voltage.
WJIA0596E
Rear blower motor should rotate.WJIA2002E
Page 501 of 3419

ATC-106
TROUBLE DIAGNOSIS
Revision: October 20052005 QX56
6. CHECK REAR BLOWER MOTOR RELAY (COIL SIDE) POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect fuse block (J/B) connector.
3. Turn ignition switch ON.
4. Set rear blower switch (front) to any position except OFF, REAR,
or 4 - speed.
5. Check voltage between fuse block (J/B) harness connector M39
terminal 3Q (W/L) and ground.
OK or NG
OK >> GO TO 7.
NG >> GO TO 20.
7. CHECK REAR BLOWER MOTOR RELAY (COIL SIDE) GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between fuse block (J/B) harness connector
M3 terminal 7N (B) and ground.
OK or NG
OK >> Replace fuse block (J/B).
NG >> Repair harness or connector.
8. REPLACE FUSE
Refer to PG-76, "
FUSE BLOCK-JUNCTION BOX(J/B)"
Fuse should not open when rear blower motor is activated.
OK or NG
OK >> Inspection End.
NG >> GO TO 9.
9. CHECK REAR BLOWER MOTOR POWER SUPPLY CIRCUIT FOR SHORT
1. Turn ignition switch OFF.
2. Disconnect battery cables and rear blower motor connector.
3. Check continuity between rear blower motor harness connector
B134 terminal 2 (L/R) and ground.
OK or NG
OK >> Check rear blower motor. Refer to ATC-100, "Front
Blower Motor" .
NG >> Repair harness or connector. 3Q - Ground : Battery voltage.
LJIA0101E
7N - Ground : Continuity should exist.
WJIA0597E
2 - Ground : Continuity should not exist.
WJIA0598E