Page 1950 of 4731
DTC P1279, P1289 A/F SENSOR 1 EC-557
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
6. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect air fuel ratio (A/F) sensor 1 harness connector.
3. Turn ignition switch ON.
4. Check voltage between air fuel ratio (A/F) sensor 1 terminal 3 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E18, F48
Fuse block (J/B) connector E201
10A fuse
Harness for open or short between air fuel ratio (A/F) sensor 1 and fuse
>> Repair or replace harness or connectors.
Voltage: Battery voltage
PBIB2190E
PBIB1683E
Page 1951 of 4731
![INFINITI FX35 2005 Service Manual EC-558
[VQ35DE]
DTC P1279, P1289 A/F SENSOR 1
Revision: 2005 July 2005 FX
8. CHECK AIR FUEL RATIO (A/F) SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect EC INFINITI FX35 2005 Service Manual EC-558
[VQ35DE]
DTC P1279, P1289 A/F SENSOR 1
Revision: 2005 July 2005 FX
8. CHECK AIR FUEL RATIO (A/F) SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect EC](/manual-img/42/57020/w960_57020-1950.png)
EC-558
[VQ35DE]
DTC P1279, P1289 A/F SENSOR 1
Revision: 2005 July 2005 FX
8. CHECK AIR FUEL RATIO (A/F) SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between the following terminals. Refer to Wiring Diagram.
4. Check harness continuity between the following terminals and ground. Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK AIR FUEL RATIO (A/F) SENSOR 1 HEATER
Refer to EC-412, "
Component Inspection" .
OK or NG
OK >> GO TO 10.
NG >> Replace air fuel ratio (A/F) sensor 1.
10. CHECK MASS AIR FLOW SENSOR
Refer to EC-193, "
Component Inspection" .
OK or NG
OK >> GO TO 11.
NG >> Replace mass air flow sensor.
A/F sensor 1 terminal ECM terminal
Bank1 116
275
535
656
Bank 2 176
277
557
658
Continuity should exist.
Bank 1 Bank 2
A/F sensor 1 terminal ECM terminal A/F sensor 1 terminal ECM terminal 116176
275277
535557
656658
Continuity should not exist.
Page 1952 of 4731
DTC P1279, P1289 A/F SENSOR 1 EC-559
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
11 . CHECK PCV VALVE
Refer to EC-51, "
POSITIVE CRANKCASE VENTILATION" .
OK or NG
OK >> GO TO 12.
NG >> Repair or replace PCV valve.
12. CHECK INTERMITTENT INCIDENT
Perform EC-163, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> GO TO 13.
NG >> Repair or replace.
13. REPLACE AIR FUEL RATIO (A/F) SENSOR 1
Replace air fuel ratio (A/F) sensor 1.
CAUTION:
Discard any air fuel ratio (A/F) sensor which has been dropped from a height of more than 0.5 m
(19.7 in) onto a hard surface such as a concrete floor; use a new one.
Before installing new air fuel ratio (A/F) sensor, clean exhaust system threads using Heated Oxy-
gen Sensor Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
>> INSPECTION END
Removal and InstallationABS00AB6
AIR FUEL RATIO (A/F) SENSOR 1
Refer to EM-26, "EXHAUST MANIFOLD AND THREE WAY CATALYST"
Page 1953 of 4731
![INFINITI FX35 2005 Service Manual EC-560
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
PFP:14920
DescriptionABS006VU
SYSTEM INFINITI FX35 2005 Service Manual EC-560
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
PFP:14920
DescriptionABS006VU
SYSTEM](/manual-img/42/57020/w960_57020-1952.png)
EC-560
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
PFP:14920
DescriptionABS006VU
SYSTEM DESCRIPTION
*1: ECM determines the start signal status by the signals of engine speed and battery voltage.
*2: This signal is sent to the ECM through CAN communication line.
This system controls flow rate of fuel vapor from the EVAP canister. The opening of the vapor by-pass pas-
sage in the EVAP canister purge volume control solenoid valve changes to control the flow rate. The EVAP
canister purge volume control solenoid valve repeats ON/OFF operation according to the signal sent from the
ECM. The opening of the valve varies for optimum engine control. The optimum value stored in the ECM is
determined by considering various engine conditions. When the engine is operating, the flow rate of fuel vapor
from the EVAP canister is regulated as the air flow changes.
COMPONENT DESCRIPTION
The EVAP canister purge volume control solenoid valve uses a ON/
OFF duty to control the flow rate of fuel vapor from the EVAP canis-
ter. The EVAP canister purge volume control solenoid valve is
moved by ON/OFF pulses from the ECM. The longer the ON pulse,
the greater the amount of fuel vapor that will flow through the valve.
CONSULT-II Reference Value in Data Monitor ModeABS006VV
Specification data are reference values.
Sensor Input Signal to ECM ECM function Actuator
Crankshaft position sensor (POS)
Camshaft position sensor (PHASE) Engine speed*
1
EVAP canister
purge flow control EVAP canister purge vol-
ume control solenoid valve
Mass air flow sensor Amount of intake air
Engine coolant temperature sensor Engine coolant temperature
Battery Battery voltage*
1
Throttle position sensor Throttle position
Accelerator pedal position sensor Accelerator pedal position
Air fuel ratio (A/F) sensor 1 Density of oxygen in exhaust gas
(Mixture ratio feedback signal)
Fuel tank temperature sensor Fuel temperature in fuel tank
Wheel sensor*
2Vehicle speed
SEF337U
MONITOR ITEM CONDITION SPECIFICATION
PURG VOL C/V
Engine: After warming up
Selector lever: P or N
Air conditioner switch: OFF
No-load Idle
(Accelerator pedal is not depressed
even slightly, after engine starting) 0%
2,000 rpm —
Page 1954 of 4731
![INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-561
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
On Board Diagnosis LogicABS006VW
DTC Confirmation Proced INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-561
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
On Board Diagnosis LogicABS006VW
DTC Confirmation Proced](/manual-img/42/57020/w960_57020-1953.png)
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-561
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
On Board Diagnosis LogicABS006VW
DTC Confirmation ProcedureABS006VX
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “PURG VOL CN/V P1444” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with CONSULT-II.
5. Touch “START”.
6. Start engine and let it idle until “TESTING” on CONSULT-II changes to “COMPLETED”. (It will take approximately 10 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG RESULTS”. If “NG” is displayed, refer to EC-
564, "Diagnostic Procedure" .
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 20 seconds.
4. Select Service $07 with GST.
5. If 1st trip DTC is detected, go to EC-564, "
Diagnostic Procedure" .
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1444
1444 EVAP canister purge
volume control solenoid
valve The canister purge flow is detected during the
specified driving conditions, even when EVAP
canister purge volume control solenoid valve is
completely closed.
EVAP control system pressure sensor
EVAP canister purge volume control
solenoid valve
(The valve is stuck open.)
EVAP canister vent control valve
EVAP canister
Hoses
(Hoses are connected incorrectly or
clogged.)
PBIB0839E
Page 1955 of 4731
EC-562
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Wiring DiagramABS006VY
TBWM0398E
Page 1956 of 4731
![INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-563
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-563
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured](/manual-img/42/57020/w960_57020-1955.png)
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-563
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.) TER-
MINAL
NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
45 GY EVAP canister purge vol-
ume control solenoid valve [Engine is running]
Idle speed
Accelerator pedal is not depressed even
slightly, after engine starting BATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Engine speed is about 2,000 rpm (More
than 100 seconds after starting engine) BATTERY VOLTAGE
(11 - 14V)
111 W / B ECM relay
(Self shut-off) [Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF 0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFF BATTERY VOLTAGE
(11 - 14V)
11 9
120 R
R Power supply for ECM
[Ignition switch: ON] BATTERY VOLTAGE
(11 - 14V)
SEC990C
SEC991C
Page 1957 of 4731
![INFINITI FX35 2005 Service Manual EC-564
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Diagnostic ProcedureABS006VZ
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SU INFINITI FX35 2005 Service Manual EC-564
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Diagnostic ProcedureABS006VZ
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SU](/manual-img/42/57020/w960_57020-1956.png)
EC-564
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Diagnostic ProcedureABS006VZ
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between EVAP canister purge volume control solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M82, F102
IPDM E/R harness connector E7
20A fuse
Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB2006E
Voltage: Battery voltage
PBIB0148E
Continuity should exist.