Page 861 of 4731
BL-46
POWER DOOR LOCK SYSTEM
Revision: 2005 July 2005 FX
4. CHECK BACK DOOR SWITCH GROUND HARNESS
Check continuity between back door switch connector D109 terminal
8 and ground.
OK or NG
OK >> Check harness connection.
NG >> Repair or replace harness.
Check Key SwitchAIS004M2
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check ignition key switch “KEY ON SW” in “DATA MONITOR” mode
with CONSULT-II.
When key is inserted in ignition key cylinder
When key is removed from ignition key cylinder
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> Key switch circuit is OK.
NG >> GO TO 2. (With Intelligent Key)
NG >> GO TO 3. (Without Intelligent Key) 8 (B) – Ground : Continuity should exist.
PIIA6477E
KEY ON SW : ON
KEY ON SW : OFF
PIIA6470E
Connector Terminal
Condition of key switch Voltage (V)
Approx.
(+) (-)
M3 37
(B/W) Ground Key is inserted in IGN
key cylinder. Battery voltage
Key is removed from IGN
key cylinder. 0
PIIA6378E
Page 866 of 4731

POWER DOOR LOCK SYSTEM BL-51
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
2. CHECK OUTPUT SIGNAL
1. Connect BCM and door lock actuator (driver side) connector.
2. Check voltage between BCM connector M4 terminals 44, 50 and ground.
OK or NG
OK >> Check harness connection.
NG >> Replace BCM.
Check Door Lock Actuator (Passenger Side and Rear LH/RH)AIS004M5
1. CHECK DOOR LOCK ACTUATOR CIRCUIT
1. Disconnect BCM and each door lock actuator connectors.
2. Check continuity between BCM connector M4 terminals 50, 51 and front door lock actuator passenger side, rear door lock actu-
ator LH/RH connectors D40, D52, D72 terminals 2, 3.
3. Check continuity between BCM connector M4 terminals 50, 51 and ground.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
Con-
nector Terminal
(Wire color) Condition Voltage (V)
(Approx.)
(+) (–)
M4 44
(Y)
Ground Driver door lock/unlock
switch is turned to
UNLOCK. 0
→ Battery voltage → 0
50
(PU) Driver door lock/unlock
switch is turned to
LOCK. 0
→ Battery voltage → 0
PIIA6383E
50 (PU) – 3 (PU) : Continuity should exist.
51 (W/B) – 2 (L or Y) : Continuity should exist.
50 (PU) – Ground : Continuity should not exist.
51 (W/B) – Ground : Continuity should not exist.
PIIA6540E
Page 867 of 4731

BL-52
POWER DOOR LOCK SYSTEM
Revision: 2005 July 2005 FX
2. CHECK DOOR LOCK ACTUATOR SIGNAL
Check voltage between BCM connector M4 terminals 50, 51 and
ground.
OK or NG
OK >> Replace front door lock assembly (passenger side) or rear door lock actuator LH/RH.
NG >> Replace BCM.
Check Fuel Lid Opener Actuator AIS004M6
1. CHECK FUEL LID OPENER ACTUATOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM and fuel lid lock actuator connector.
3. Check continuity between BCM connector M4 terminals 44, 50 and fuel lid lock actuator connector B70 terminals 1, 2.
4. Check continuity between BCM connector M4 terminals 44, 50 and ground.
OK or NG
OK >> Replace fuel lid actuator.
NG >> Repair or replace harness.
Con-
nector Terminal
(Wire color) Condition Voltage (V)
(Approx.)
(+) (–)
M4 50
(PU) Ground Door lock/unlock switch
is turned to LOCK. 0
→ Battery voltage → 0
51
(W/B) Door lock/unlock switch
is turned to UNLOCK. 0
→ Battery voltage → 0
PIIA6385E
44 (Y) – 2 (L) : Continuity should exist.
50 (PU) – 1 (PU) : Continuity should exist.
44 (Y) – Ground : Continuity should not exist.
50 (PU) – Ground : Continuity should not exist.
PIIA6386E
Page 879 of 4731

BL-64
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2005 July 2005 FX
Terminals and Reference Value for BCMAIS004MF
TERMI-
NAL WIRE
COLOR ITEM CONDITION VOLTAGE (V)
Approx.
1PU Key ring illumination output sig-
nal Key ring illumination is lighting. Battery voltage
Key ring illumination is being turned off. 0
11 LG/R Ignition switch Ignition switch is in ACC or ON position Battery voltage
12 P/B Front door switch (Passenger
side) ON (door open)
→ OFF (door closed) 0 → Battery voltage
13 P/L Rear door switch RH ON (door open) → OFF (door closed) 0 → Battery voltage
18 B Remote keyless entry receiver
(Ground) —0
19 R Remote keyless entry receiver
(Power supply) —
20 Y Remote keyless entry receiver
(Signal) Stand-by
When remote keyless entry receiver
receives signal from keyfob.
37 B/W Key switch ON (Key is inserted in IGN key cylinder)
→ OFF (Key is removed from IGN key
cylinder) Battery voltage
→ 0
38 W/L Ignition switch Ignition switch is in ON or START posi-
tion Battery voltage
39 L CAN H — —
40 R CAN L — —
41 R/B Battery saver output signal 30 minutes after ignition switch is turned
to OFF 0
Ignition switch is in ON position Battery voltage
42 L/R Battery power supply (fuse) — Battery voltage
44 Y Driver door lock actuator
(Unlock) Door lock / unlock switch
(Free → Unlock) 0
→ Battery voltage
45 G/W Left turn signal lamp When door lock or unlock is operated
using key fob.*
1
(ON → OFF) Battery voltage
→ 0
46 BR/W Right turn signal lamp When door lock or unlock is operated
using key fob.*
1
(ON → OFF) Battery voltage
→ 0
47 Y/R Step lamp output signal Step lamp is lighting. 0
Step lamp is being turned off. Battery voltage
OCC3881D
OCC3879D
OCC3880D
Page 880 of 4731

REMOTE KEYLESS ENTRY SYSTEM BL-65
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
*1 : In the state that hazard reminder operates.
*2 : In the state that room lamp switch is in “DOOR” position.
Terminals and Reference Value for IPDM E/RAIS004MG
* : In the state that horn reminder operates. 48 PU/W Room lamp output signal
Room lamp is lighting.*
20
Room lamp is being turned off.*
2Battery voltage
49, 52 B Ground — 0
50 PU Door lock actuator (Lock) Door lock / unlock switch
(Free → Lock) 0
→ Battery voltage
51 W/B Passenger and rear doors lock
actuator (Unlock) Door lock / unlock switch
(Free → Unlock) 0
→ Battery voltage
54 W Battery power supply
(power window) — Battery voltage
55 G Battery power supply (Fusible
link) — Battery voltage
58 L Back door switch OFF (Door close) → ON (Door open) 9 → 0
62 W Front door switch (Driver side) OFF (Door close) → ON (Door open) Battery voltage → 0
63 P Rear door switch LH OFF (Door close) → ON (Door open) Battery voltage → 0
TERMI-
NAL WIRE
COLOR ITEM CONDITION VOLTAGE (V)
Approx.
TERMINAL WIRE
COLOR ITEM CONDITION VOLTAGE (V)
Approx.
38 B Ground — 0
48 L CAN H — —
49 R CAN L — —
51 SB Horn relay When door lock is operated using key
fob* (OFF → ON) Battery voltage
→ 0
60 B Ground — 0
Page 885 of 4731

BL-70
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2005 July 2005 FX
Trouble Diagnosis Chart by SymptomAIS004MJ
NOTE:
Always check the “Work Flow” before troubleshooting. Refer to BL-69, "Work Flow" .
Always check key fob battery before replacing key fob.
Symptom Diagnoses/service procedure Reference
page
All function of remote keyless entry system do not
operate. 1. Check key fob battery and function.
BL-72
2. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-84
3. Check remote keyless entry receiver.
BL-79
4. Replace BCM.BCS-16
The new ID of key fob cannot be entered. 1. Check key fob battery and function.
BL-72
2. Check key switch.BL-78
3. Check door switch.BL-74
4. Check ACC switch.BL-73
5. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-84
6. Replace BCM.
BCS-16
Door lock or unlock does not function with key fob.
(Power door lock system is “OK”.) 1. Check key fob battery and function.
BL-72
2. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-84
3. Replace BCM.
BCS-16
Hazard and horn reminder does not activate prop-
erly when pressing lock or unlock button of key fob. 1. Check hazard and horn reminder mode.*
*: Hazard and horn reminder mode can be changed.
First check the hazard and horn reminder setting. BL-68
2. Check door switch.
BL-74
3. Replace BCM.BCS-16
Hazard reminder does not activate properly when
pressing lock or unlock button of key fob.
(Horn reminder is “OK”.) 1. Check hazard reminder mode.*
*: Hazard reminder mode can be changed.
First check the hazard reminder setting. BL-68
2. Check hazard function with hazard switch.
BL-83
3. Replace BCM.BCS-16
Horn reminder does not activate properly when
pressing lock button of key fob.
(Hazard reminder is “OK”.) 1. Check horn reminder mode.*
*: Horn reminder can be changed.
First check the horn chirp setting. BL-68
2. Check horn function.
BL-83
3. Check IPDM E/R operation.BL-82
4. Replace BCM.BCS-16
Page 886 of 4731

REMOTE KEYLESS ENTRY SYSTEM BL-71
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Panic alarm (horn and headlamp) does not activate
when panic alarm button is continuously pressed. 1. Check panic alarm mode.*
*: Panic alarm mode can be changed.
First check the panic alarm setting. BL-68
2. Check key fob battery and function.
BL-72
3. Check headlamp function.BL-83
4. Check horn function.BL-83
5. Check IPDM E/R operation.BL-82
6. Check key switch.BL-78
7. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-84
8. Replace BCM.
BCS-16
Auto door lock operation does not activate properly.
(All other remote keyless entry system function is
OK.) 1. Check auto door lock operation mode.*
*: Auto door lock operation mode can be changed.
First check the auto door lock operation setting. BL-68
2. Replace BCM.
BCS-16
Keyless power window down (open) operation does
not activate properly.
(All other remote keyless entry system function is
OK.) 1. Check power window down operation mode.*
*: Power window down operation mode can be changed.
First check the power window down setting. BL-68
2. Check power window function.
GW-15
3. Replace BCM.BCS-16
Map lamp and ignition keyhole illumination opera-
tion does not activate properly. 1. Check map lamp and ignition keyhole illumination operation.
BL-832. Check door switch.BL-74
3. Replace BCM.BCS-16
Symptom Diagnoses/service procedure Reference
page
Page 887 of 4731
BL-72
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2005 July 2005 FX
Check Key Fob Battery and FunctionAIS004MK
1. CHECK KEY FOB BATTERY
1. Remove key fob battery. Refer to BL-88, "
Key Fob Battery Replacement" .
2. Measure voltage between battery positive and negative termi- nals, (+) and ( −).
NOTE:
Key fob does not function if battery is not set correctly.
OK or NG
OK >> GO TO 2.
NG >> Replace battery.
2. CHECK KEY FOB FUNCTION
With CONSULT-II
Check key fob function in “DATA MONITOR” mode with CONSULT-
II. When pushing each button of key fob, the corresponding monitor
item should be turned as follows.
OK or NG
OK >> Key fob is OK.
NG >> Replace key fob. Voltage : 2.5 – 3.0V
SEL237W
Condition Monitor item
Pushing LOCK KEYLESS LOCK : ON
Pushing UNLOCK KEYLESS UNLOCK : ON
Keep pushing UNLOCK RKE KEEP UNLK : ON
Pushing PANIC KEYLESS PANIC : ON
Pushing LOCK and UNLOCK at the
same time RKE LCK-UNLOCK : ON
PIIA6468E