An additional on-board power supply control unit is
needed in the Audi A6 ´05 because of the huge
range of functions it offers.
Functions
Control unit 2 for on-board power supply J520
includes the following functions:
– Activate the solenoid valve for Servotronic N119
– Sliding roof convenience opening/closing
– Speed signal for sliding roof
– Tilt sensor for anti-theft warning system
– Glove compartment release
Installation position
Control unit 2 for on-board power supply is located
behind the glove compartment in the module
carrier on the passenger’s side.
Versi on s
Two different versions of control unit 2 for on-board
power supply are available, depending on the
vehicle equipment.
–Low version
(only includes glove compartment release and
Servotronic function only)
–High version
(also with sliding roof/anti-theft warning system)
Convenience electrics
Control unit 2 for on-board power supply J520
326_103
Downloaded from www.Manualslib.com manuals search engine 53
Function diagram
326_082
Legend
E316 Glove compartment button
J520 Control unit 2 for on-board power supply
N119 Solenoid valve for Servotronic
V1 Motor for sliding roof
V327 Motor for glove compartment releaseAdditional signals
1CAN Convenience High
2CAN Convenience Low
Downloaded from www.Manualslib.com manuals search engine 54
The tilt sensor for the anti-theft warning system is
integrated directly in control unit 2 for on-board
power supply J520 in the new Audi A6 ‘05.
The fluid-filled sensor registers changes in the
vehicle tilt both transversely and longitudinally,
thereby preventing incorrect triggering as a result of
shaking through viscous fluid and electronic delay.
The current tilt values can be read out using
measured-value blocks.
Diagnosis
– Measured-value blocks
Measured-value blocks are available for the
following functions:
– Servotronic
– Sliding roof
– Tilt angle
–Actuator test
Checks can be carried out for the following
functions, depending on the version:
– Glove compartment release
– Servotronic valve
– Sliding roof activation (can be measured
using a multimeter on the on-board power
supply control unit, sliding roof does not
open, however, if it is not released by the
central control unit for the convenience
system)
–Coding
The High-Line version of control unit 2 for
on-board power supply J520 must be coded for
the following functions:
– Tilt sensor (with or without)
– Sliding roof (with or without)
Convenience electrics
Note
The tilt sensor function can be switched off
using a button in the driver’s door panel.
Reference
For further information on the tilt sensor
function, please refer to the SSP 254,
Audi A4 ‘01 – Technology.
Tilt sensor for anti-theft warning system