Page 24 of 801

YH4
GRAND
VITARA
GENERAL INFORMATION 0A-21
A
ABS : Anti-lock Brake System
ATDC : After Top Dead Center
API : American Petroleum Institute
ATF : Automatic Transmission Fluid
ALR : Automatic Locking Retractor
AC : Alternating Current
A / T : Automatic Transmission
A / C : Air Conditioning
ABDC : After Bottom Dead Center
A / F : Air Fuel Mixture Ratio
A-ELR : Automatic-Emergency
Locking Retractor
B
B+ : Battery Positive Voltage
BTDC : Before Top Dead Center
BBDC : Before Bottom Dead Center
C
CKT : Circuit
CMP Sensor : Camshaft Position Sensor
(Crank Angle Sensor, CAS)
CO : Carbon Monoxide
CPP Switch : Clutch Pedal Position Switch
(Clutch Switch, Clutch Start
Switch)
CPU : Central Processing Unit
CRS : Child Restraint System
D
DC : Direct Current
DLC : Data Link Connector
(Assembly Line Diag. Link,
ALDL, Serial Data Link, SDL)
DOHC : Double Over Head Camshaft
DOJ : Double Offset Joint
DRL : Daytime Running Light
DTC : Diagnostic Trouble Code
(Diagnostic Code)
E
EBCM : Electronic Brake Control
Module, ABS Control
Module
EBD : Electric Brake force Distribution
ECM : Engine Control Module
ECT Sensor : Engine Coolant Temperature
Sensor (Water Temp.
Sensor, WTS)
EGR : Exhaust Gas Recirculation
EGRT Sensor : EGR Temperature Sensor
(Recirculated Exhaust Gas
Temp. Sensor, REGTS)
EFE Heater : Early Fuel Evaporation
Heater (Positive Temperature
Coefficient, PTC Heater)
ELR : Emergency Locking Retractor
EPS : Electronic Power Steering
EVAP : Evaporative Emission
EVAP Canister : Evaporative Emission
Canister (Charcoal Canister)
F
4WD : 4 Wheel Drive
G
GEN : Generator
GND : Ground
H
HC : Hydrocarbons
HO2S : Heated Oxygen Sensor
I
IAC Valve : Idle Air Control Valve (Idle
Speed Control Solenoid
Valve, ISC Solenoid Valve)
IAT Sensor : Intake Air Temperature
Sensor (Air temperature
Sensor, ATS)
ICM : Immobilizer Control Module
IG : Ignition
ISC Actuator : Idle Speed Control Actuator
(Motor)
ABBREVIATIONS MAY BE USED IN THIS MANUAL
Page 73 of 801

YH4
GRAND
VITARA
1B-2 AIR CONDITIONING (OPTIONAL)
Condenser Dryer (Receiver / Dryer) 1B-36. . . . . .
Air Filter Element 1B-37. . . . . . . . . . . . . . . . . . . . .
Cooling Unit (Evaporator) 1B-39. . . . . . . . . . . . . .
Expansion Valve 1B-42. . . . . . . . . . . . . . . . . . . . .
A / C Evaporator Thermistor (Evaporator
Temperature Sensor) 1B-43. . . . . . . . . . . . . . . .
Refrigerant Pipes and Hoses 1B-44. . . . . . . . . . .
A / C Switch 1B-45. . . . . . . . . . . . . . . . . . . . . . . . . .
A / C Controller 1B-46. . . . . . . . . . . . . . . . . . . . . . . .
Dual Pressure Switch 1B-47. . . . . . . . . . . . . . . . . A / C Compressor Relay and A / C
Condenser Cooling Fan Relay 1B-48. . . . . . . .
Compressor Assembly 1B-49. . . . . . . . . . . . . . . .
Magnet Clutch Assembly
(For Denso Compressor) 1B-53. . . . . . . . . . .
Magnet Clutch Assembly
(For Seiko Seiki Compressor) 1B-56. . . . . . .
Lip Type Seal (For Seiko Seiki) 1B-59. . . . . . .
REQUIRED SERVICE MATERIAL1B-61 . . . . . . . .
SPECIAL TOOLS1B-61 . . . . . . . . . . . . . . . . . . . . . .
Page 87 of 801
YH4
GRAND
VITARA
1. Blower motor main relay
2. Blower motor
3. Blower motor resistor
4. Blower motor switch
5. A / C controller
6. ECM
7. Heater mode control switch
8. Evaporator temperature sensor
9. Refrigerant pressure switch10. Compressor relay
11. Compressor
12. Condenser cooling fan relay
13. Condenser cooling fan
14. Fuse box
15. A / C fuse 25 A
16. Ignition switch
17. Main fuse box
18. Battery main fuse 80 A19. Battery
20. Generator
21. Ignition main fuse 60 A
22. Heater/A/C main fuse 60 A
23. Ignition / meter fuse 20 A
24. Rear defogger fuse 15 A
25. Heater fuse 30 A
26. Compressor thermal switch
(only IWATA production vehicle)
FOR LH VEHICLE
1B-16 AIR CONDITIONING (OPTIONAL)
WIRING CIRCUIT
Page 88 of 801
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-17
1. Blower motor main relay
2. Blower motor
3. Blower motor resistor
4. Blower motor switch
5. A / C controller
6. ECM
7. Heater mode control switch
8. Evaporator temperature sensor
9. Refrigerant pressure switch
FOR RH VEHICLE
10. Compressor relay
11. Compressor
12. Condenser cooling fan relay
13. Condenser cooling fan
14. Fuse box
15. A / C fuse 25 A
16. Ignition switch
17. Main fuse box
18. Battery main fuse 80 A19. Battery
20. Generator
21. Ignition main fuse 60 A
22. Heater/A/C main fuse 60 A
23. Ignition / meter fuse 20 A
24. Rear defogger fuse 15 A
25. Heater fuse 30 A
26. Compressor thermal switch
(only IWATA production vehicle)
Page 90 of 801
YH4
GRAND
VITARA
SYSTEM CIRCUIT
A. To heater fuse
B. To rear defogger fuse
C. To ignition / meter fuse
D. To A / C fuse
E. Only LH vehicle1. Blower motor relay
2. Blower motor
3. Blower motor switch
4. A / C switch
5. Deflloster position switch
6. Deflloster / foot position switch7. Dual pressure (refrigerant
pressure) switch
8. A / C thermistor (evaporator
temperature sensor)
9. Compressor relay
10. Compressor11. Condenser fan motor relay
12. Condenser fan motor
13. A / C controller
14. ECM
15. Compressor thermal switch
(only IWATA production vehicle)
TERMINAL ARRANGEMENT OF A / C CONTROLLER
TERMINAL ARRANGEMENT OF ECM FOR G16, J20 ENGINE
TERMINAL ARRANGEMENT OF ECM FOR H25 ENGINE
H25 engine
E61-27
G16, J20
engines
E61-8
H25 engine
E61-28
G16, J20
engines
E61-17
1919
19H25 engine
E61-5
G16, J20
engines
E61-22
AIR CONDITIONING (OPTIONAL) 1B-19
Page 92 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-21
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC2-1L/YSensor groundGround to body
(Fig. A)± 0.4 ± 0 voltEngine running
1.5 volts
(3150 )Evaporator thermistor temperature at
approx. 15C (59F) with engine
running
AC2-2W/B
Evaporator
thermistor
temperature
(evaporator temp.
sensor) input
Ground to engine
(Fig. B)
2.62 volts
(6.311 )
Evaporator thermistor temperature at
approx. 1C (34F) with engine
running
* If the temperature is less than
approx. 1C, in this case
compressor and condenser fan
should be stop (come back at more
than approx. 2.5C (less than
5840 , 2.5 V))
H25
engine
E61-27 /
G16 J20Gr/W
Signal output to
A / C controller
(A / C ON
Ground to engine
(Fig C)
10 ± 14 volts
Required A / C ON (terminal AC-A13)
at engine running with normal
condition (refer to ªINSPECTION OF
ECM AND ITS CIRCUITº in Section
6E)
G16, J20
engines
E61-8
(
permission
signal)(Fig. C)
0 ± 1 volt
Except the above-mentioned with
engine running
In this case compressor should be
stop
H25
engine
E61-28 /
Y/B
Signal input from
A / C controller
Ground to engine
0 ± 1.5 voltsRequire A / C ON
G16, J20
engines
E61-17Y/B(A / C ON request
signal)
g
(Fig. C)
10 ± 14 voltsTurn off the A / C
H25
engine
E61-5 /
G16, J20
engines
E61-22
Y/L
A / C condenser
cooling fan relay
outputGround to engine
(Fig. C)0 ± 1 volt
Blower fan motor switch and A / C or
defroster position switch (see
NOTE) ON with engine running at
evaporator thermistor temperature
input more than approx. 2.5C (less
than 2.5 V (5840 )), refrigerant
pressure switch ON and signal
input from ECM ON
Engine coolant temperature sensor
more than 113C (236F) with
engine running
10 ± 14 voltsExcept the above-mentioned with
engine running
NOTE:
Defroster position switch circuit is equipped with LH vehicle only.
Page 111 of 801
YH4
GRAND
VITARA
1
1B-40 AIR CONDITIONING (OPTIONAL)
3) Remove upper case (1) and remove evaporator (2) from lower
case (3).
4) Remove following components from evaporator.
Expansion valve (5)
Thermistor (evaporator temperature sensor) (4)
DISASSEMBLY (FOR IWATA PRODUCTION VEHICLE)
1) Remove filter (2) from cooling unit (3) assembly by removing fil-
ter cover (1).
2) Detach clamps (1) to separate evaporator upper and lower
cases from each other.
3) Remove upper case (1) and remove evaporator (2) from lower
case (3).
4) Remove following components from evaporator.
Expansion valve (5)
Thermistor (evaporator temperature sensor) (4)
Page 114 of 801
YH4
GRAND
VITARA
1. Evaporator thermistorTemperature
Resistance ( )
AIR CONDITIONING (OPTIONAL) 1B-43
A / C EVAPORATOR THERMISTOR
(EVAPORATOR TEMPERATURE SENSOR)
A thermistor is a temperature sensor to sense the temperature of
air discharged from evaporator. The electrical characteristic is
shown in the figure.
When temperature is lower than preset temperature, amplifier
makes magnet clutch turn off to prevent evaporator from frosting.
INSPECTION
Check resistance between A / C evaporator thermistor (1) termi-
nals.
If check results are as not specified, replace thermistor.
Sensor Temperature
Resistance
0C, 32F7.0 ± 7.7 k
25C, 77F2.1 ± 2.4 k
REMOVAL
Refer to ªCOOLING UNIT (EVAPORATOR)º in this section.
INSTALLATION
1) Reverse removal sequence to install thermistor.
2) Enable air bag system. Refer to ªENABLING AIR BAG SYS-
TEMº in Section 10B.
3) Evacuate and charge system. Refer to ªEVACUATINGº and
ªCHARGINGº in this section.