Page 571 of 801

YH4
GRAND
VITARA
1. Heat wire
2. Tin foil
3. Tester probe
1. VoltmeterAt center
Good
Broken
wire
broken
wire
8D-16 WINDOWS, MIRRORS, SECURITY AND LOCKS
REAR WINDOW DEFOGGER (IF EQUIPPED)
INSPECTION
DEFOGGER SWITCH
Check for continuity between terminals at each switch position as
shown below.
If check result is not as specified, replace switch.
DEFOGGER WIRE
NOTE:
When cleaning rear window glass, use a dry cloth to wipe it
along wire direction.
When cleaning glass, do not use detergent or abrasive-con-
taining glass cleaner.
When measuring wire voltage, use a tester with negative
probe wrapped with a tin foil which should be held down on
wire by finger pressure.
1) Checking wire damage
a. Turn main switch ON.
b. Turn defogger switch ON.
c. Use a voltmeter to check voltage at the center of each heat
wire, as shown.
Voltage
Criteria
Approx. 5 VGood (No break in wire)
Approx. 10 V or 0 VBroken wire
If measured voltage is 10 V, wire must be damaged between
its center and positive end. If voltage is zero, wire must be
damaged between its center and ground.
Page 573 of 801
YH4
GRAND
VITARA
Type 1
Type 2
LH steering vehicle
Terminal
Switch
Terminal
Switch
8D-18 WINDOWS, MIRRORS, SECURITY AND LOCKS
POWER WINDOW CONTROL SYSTEM
INSPECTION
POWER WINDOW MAIN SWITCH
Check switch for continuity between terminals as shown below.
Type 1
WindowDriver SidePassenger SideWindowLockWindow Switch (2)gWindow Switch (3)LockSwitch (1)CHGACEBAAF
UPUP
OFFOFFOFFOFF
DOWNDOWN
UPUP
ONOFFONOFF
DOWNDOWN
Type 2 LH steering vehicle
Window
Lock
Switch (1)
Driver
Side
Window
Switch (2)Passenger
Side
Window
Switch (3)Rear RH
Window
Switch (4)Rear LH
Window
Switch (5)
Switch (1)
KCABKCEFKCIJKCGHKCABKCEFKCIJKCGH
UPUP
OFFOFFOFFOFF
DOWNDOWN
UPUP
ONOFFONOFF
DOWNDOWN
Page 574 of 801
YH4
GRAND
VITARA
Terminal
Switch
Terminal
Switch
Position
Type 2
RH steering vehicle
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-19
Type 2 RH steering vehicle
Window
Lock
Switch (1)
Driver
Side
Window
Switch (2)Passenger
Side
Window
Switch (3)Rear RH
Window
Switch (4)Rear LH
Window
Switch (5)
Switch (1)
KCEFKCABKCIJKCGHKCEFKCABKCIJKCGH
UPUP
OFFOFFOFFOFF
DOWNDOWN
UPUP
ONOFFONOFF
DOWNDOWN
POWER WINDOW SUB SWITCH
Check switch for continuity between terminals as shown below.
CBEADCBEAD
UPUP
OFFOFF
DOWNDOWN
Page 575 of 801

YH4
GRAND
VITARA
Terminal
Switch
Type 1
Type 2
1. Door lock switch
2. Door lock switch coupler
Terminal
Switch
8D-20 WINDOWS, MIRRORS, SECURITY AND LOCKS
POWER DOOR LOCK SYSTEM (IF KEYLESS
ENTRY IS NOT EQUIPPED)
INSPECTION
POWER DOOR LOCK SWITCH
Check for continuity between terminals at each switch position as
shown below.
Type 1
ALK
LOCK
NEUTRAL
UNLOCK
Type 2
ABF
LOCK
OFF
UNLOCK
POWER DOOR LOCK CONTROLLER (CANVAS TOP
MODEL)
1) Disconnect power door lock controller coupler.
2) Connect (+) wire and (±) wire of 12 V battery to terminal ªAº, ªEº
and ªFº as shown in figure.
3) Disconnect cord from terminal ªEº and connect it to terminal ªGº.
4) Repeat Steps 2) and 3) several times and if relay operation is
heard every time, it means that controller is operating.
POWER DOOR LOCK CONTROLLER (HARD TOP MODEL)
1) With the driver side door key turned LOCK, check all power
doors are locked.
2) With the driver side door key turned UNLOCK, check only the
driver side power door is unlocked.
Turn the driver side door key to UNLOCK again within 5 se-
conds, check all power doors are unlocked.
If check result of Step 1) and Step 2) is satisfactory, power door lock
controller is OK. If check result is not satisfactory, go to next Step 3).
3) Disconnect negative cable at battery.
4) Disconnect coupler of power door lock controller.
5) Use a 12 V battery to connect its (+) terminal to terminal E02-1,
and its (±) terminal to terminal E02-2 and E02-3. Check all power
doors are locked.
If check result is not satisfactory, repair circuit and recheck.
If check result is satisfactory, go to next Step 6).
Page 576 of 801
YH4
GRAND
VITARA
Terminal
Key
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-21
6) Connect negative cable at battery.
7) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-7 and
groundAnytime10 ± 14 V
E02-14 and
groundAnytimecontinuity
E02-8 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is LOCK positionContinuity
E02-9 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is UNLOCK positionContinuity
If check result is not satisfactory, repair circuit and recheck.
If check result is satisfactory, replace controller.
KEY CYLINDER SWITCH (DRIVER SIDE)
Check for continuity between terminals according to the key action
shown below.
321
LOCK
OFF
UNLOCK
Page 578 of 801

YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-23
POWER DOOR LOCK AND KEYLESS ENTRY SYSTEM (IF KEYLESS ENTRY IS
EQUIPPED)
SYSTEM INSPECTION
STEPACTIONYESNO
1Check power door lock operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 2.Go to Step 3.
2Check keyless entry operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 4.Go to Step 6.
3Check keyless entry operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 5.Go to Step 7.
4Check hazard warning lights operation referring to
its INSPECTION in this section.
Is this operation OK?This system is OK.Go to Step 10.
5Check door lock key and power door lock switch
circuit referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
6Check ignition switch and door switch circuit
referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
7Check power door lock actuator circuit referring to
its INSPECTION in this section.
Is this circuit OK?Go to Step 8.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
If OK, go to Step 4.
If not OK, go to next
Step 8.
8Check power supply and grounding circuit
referring to its INSPECTION in this section.
Is this circuit OK?Go to Step 9.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
If OK, go to Step 4.
If not OK, go to next
Step 9.
91) Check door lock key and power door lock
switch circuit referring to its INSPECTION in
this section.
2) Check ignition switch and door switch circuit
referring to its INSPECTION in this section.
Are these circuits OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
Page 579 of 801

YH4
GRAND
VITARA
8D-24 WINDOWS, MIRRORS, SECURITY AND LOCKS
STEPACTIONYESNO
10Check that hazard warning lights flash with hazard
switch ON.
Is check result OK?Go to Step 11.Refer to ªTurn Signal
and Hazard Warning
Lightsº in DIAGNOSIS
and repair.
And go to Step 4.
11Check door knob switch and turn signal relay
circuit referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
POWER DOOR LOCK OPERATION
INSPECTION
1) With the driver side door key turned LOCK, check all power
doors are locked.
2) With the driver side door key turned UNLOCK, check only the
driver side power door is unlocked.
Turn the driver side door key to UNLOCK again within 5 se-
conds, check all power doors are unlocked.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
KEYLESS ENTRY OPERATION
INSPECTION
1) With the IG switch OFF and all doors closed, push LOCK button
on transmitter. Check all power doors are locked.
2) Push UNLOCK button on transmitter. Check only driver side
power door is unlocked.
3) Push UNLOCK button on transmitter again within 5 seconds.
Check all power doors are unlocked.
But if any door is not opened within 30 seconds after power
door(s) unlocked, all power doors are locked again automatical-
ly.
If check result of Step 1) to Step 3) is satisfactory, this operation is
OK.
HAZARD WARNING LIGHTS OPERATION
INSPECTION
1) Check that hazard warning lights flash one time when power
doors are locked by pushing LOCK button on transmitter.
2) Check that hazard warning lights flash two times when power
door(s) is (are) unlocked by pushing UNLOCK button on trans-
mitter.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
Page 580 of 801

YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-25
POWER DOOR LOCK ACTUATOR CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller.
3) Use a 12 V battery to connect its (+) terminal to terminal E02-1,
and its (±) terminal to terminal E02-2 and E02-3. Check all power
doors are locked.
If check result is satisfactory, this circuit is OK.
POWER SUPPLY AND GROUNDING CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-7 and
groundAnytime10 ± 14 V
E02-14 and
groundAnytimeContinuity
If check result is satisfactory, this circuit is OK.
DOOR LOCK KEY AND POWER DOOR LOCK SWITCH
CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller.
3) Check for continuity between following terminals at each condi-
tion.
Terminals
ConditionSpecification
E02-8 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is LOCK positionContinuity
E02-9 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is UNLOCK positionContinuity
If check result is satisfactory, this circuit is OK.