YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-15
1. Main fuse
2. Main relay
3. ECM/PCM
4. Immobilizer indicator lamp
(Vehicle not equipped with
monitor coupler) For G16 / J20 engine For H25 engine
G16 / J20 Engine
H25 Engine
TABLE B IMMOBILIZER INDICATOR LAMP CHECK
(IMMOBILIZER INDICATOR LAMP DOSE NOT LIGHT AT IGNITION
SWITCH ON)
STEPACTIONYESNO
11) Turn ignition switch ON.
Do other indicator / warning lights in
combination meter come ON?Go to Step 2.ªIGº fuse blown, main fuse blown,
ignition switch malfunction,
ªB / Wº circuit between ªIGº fuse
and combination meter or poor
coupler connection at
combination meter.
21) Turn ignition switch OFF and
disconnect connectors from ECM /
PCM.
2) Check for proper connection to ECM /
PCM at terminal E61-5 for G16 / J20
engine or E61-23 for H25 engine.
3) If OK, then using service wire, ground
terminal E61-5 for G16 / J20 engine or
E61-23 for H25 engine in connector
disconnected.
Does immobilizer indicator lamp turn on
at ignition switch ON?Substitute a known-
good ECM / PCM and
recheck.Bulb burned out or ª(b)º wire
circuit open.
YH4
GRAND
VITARA
10B-12 AIR BAG SYSTEM
1. Data link connector (DLC)
2. DLC cable adapter
3. DLC cable
-1. ªAIR BAGº
warning lamp
-2. ªAIR BAGº fuse box
-3. ªAIR BAGº
monitor coupler
3-1. Diagnostic switch
terminal
-4. Air bag harness
(covered yellow tube)
EXAMPLE: When driver air bag initiator circuit resistance high (Code No.21) is set
Malfunction indicator lamp
(ªAIR BAGº warning lamp)
Turn ON
Turn OFF
Time (sec.) Code No. 21 Code No. 21 Code No. 21 1
DIAGNOSTIC TROUBLE CODE (DTC) CHECK
[Using SUZUKI scan tool]
1) Turn ignition switch OFF.
2) After setting cartridge to Tech 1, connect it to data link connector
(DLC) located on underside of instrument panel at driver's seat
side.
Special Tool
(A): 09931-76011 (Tech 1)
(B): Mass storage cartridge
(C): 09931-76030
3) Turn ignition switch ON.
4) Read DTC according to instructions displayed on Tech 1 and
print it or write it down. Refer to Tech 1 operator's manual for fur-
ther details.
5) After completing the check, turn ignition switch OFF and discon-
nect Tech 1 from data link connector (DLC).
[Not using SUZUKI scan tool]
1) Check that malfunction indicator lamp (ªAIR BAGº warning
lamp) comes ON when ignition switch is turned ON.
If it does not come ªONº, proceed to ªTable Bº on p.10B-18.
2) Using service wire, ground diagnosis switch terminal in monitor
coupler.
3) Read DTC from flashing pattern of malfunction indicator lamp
(ªAIR BAGº warning lamp). (Refer to ªDiagnostic Trouble Code
Tableº on p.10B-14 and 10B-15.)
4) After completing the check, turn ignition switch OFF and discon-
nect service wire from ªAIR BAGº monitor coupler.