Page 568 of 801
YH4
GRAND
VITARA
Terminal
Switch
Terminal
Switch
ON
INT
WASHER
ON
BRINT
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-13
REAR WIPER AND WASHER (IF EQUIPPED)
INSPECTION
Rear Wiper and Washer Switch (in Combination Switch)
1) Disconnect negative cable at battery.
2) Disconnect combination switch lead wire coupler.
3) Check for continuity between terminals at each switch position
as shown below. If check result is not as specified, replace
switch.
Rear Wiper Switch
BRINT+IRBRINT+IR
OFF
INT
ON
Rear Washer Switch
BRWRBRWR
OFF
ON
Washer Pump
Refer to FRONT WIPER AND WASHER INSPECTION in this sec-
tion.
Wiper Motor
1) TESTING WIPER MOTOR
As shown left, use a 12 V battery to connect its (+) and (±) termi-
nals to terminal ªDº and Black lead wire (2) respectively. Then
motor (1) should rotate at 35 to 45 rpm.
Page 569 of 801

YH4
GRAND
VITARA
8D-14 WINDOWS, MIRRORS, SECURITY AND LOCKS
2) TESTING AUTOMATIC STOP ACTION
a) First, connect battery (+) terminal to terminal ªDº and battery
(±) terminal to black lead wire (2) and let the motor (1) turn.
b) Then disconnect terminal ªDº from battery and let the motor
stop.
c) Next connect terminal ªDº and terminal ªAº with a jumper wire
(3) and connect terminal ªBº to battery (+) terminal. Observe the
wiper motor turns once again, then stops at a given position.
d) Repeat these steps several times, and inspect if the motor
stops at the given position every time.
Rear Wiper Intermittent Relay
[ON circuit]
1) Connect positive terminal of battery to terminals ª1º and ª4º of
relay, negative terminal to terminal ª5º of relay and check voltage
between terminals ª6º and ª5º of relay.
If measured voltage is battery voltage, relay is in good condition.
If not, replace relay.
2) Connect positive terminal of battery to terminal ª2º of relay, then
disconnect positive terminal from terminal ª4º of relay and check
voltage between terminals ª6º and ª5º of relay.
If measured voltage is battery voltage, relay is in good condition.
If not, replace relay.
3) Disconnect positive terminal from terminal ª2º of relay and check
voltage between terminals ª6º and ª5º of relay.
If measured voltage is about 0 V, relay is in good condition.
If not, replace relay.
[WASH circuit]
1) Connect positive terminal of battery to terminal ª1º of relay and
negative terminal to terminal ª5º of relay. Then connect positive
terminal to terminal ª7º checking voltage between terminals ª6º
and ª5º of relay.
If measured voltage changes from about 0 V to battery voltage
0.6 to 1.5 seconds after connecting positive terminal to terminal
ª7º, relay is in good condition. If not, replace relay.
Page 570 of 801

YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-15
2) Disconnect positive terminal from terminal ª7º checking voltage
between terminal ª6º and ª5º of relay.
If measured voltage changes from battery voltage to about 0 V
2.7 to 4.6 seconds after disconnecting positive terminal from ter-
minal ª7º, relay is in good condition.
If not, replace relay.
[INT circuit]
1) Connect positive terminal of battery to terminals ª1º of relay and
negative terminal to terminal ª5º of relay. Then positive terminal
to terminal ª3º of relay checking voltage between terminals ª6º
and ª5º of relay.
If measured voltage changes from about 0 V to battery voltage
when connecting positive terminal to terminal ª3º, relay is in
good condition.
If not, replace relay.
2) Connect positive terminal of battery to terminal ª2º of relay, then
disconnect positive terminal from terminal ª2º of relay checking
voltage between terminals ª6º and ª5º of relay.
If measured voltage changes from battery voltage to about 0 V
when disconnecting positive terminal from terminal ª2º and
about 0 V to battery voltage 8 2 seconds after disconnecting
positive terminal from terminal ª2º, relay is in good condition.
If not, replace relay.
Page 575 of 801

YH4
GRAND
VITARA
Terminal
Switch
Type 1
Type 2
1. Door lock switch
2. Door lock switch coupler
Terminal
Switch
8D-20 WINDOWS, MIRRORS, SECURITY AND LOCKS
POWER DOOR LOCK SYSTEM (IF KEYLESS
ENTRY IS NOT EQUIPPED)
INSPECTION
POWER DOOR LOCK SWITCH
Check for continuity between terminals at each switch position as
shown below.
Type 1
ALK
LOCK
NEUTRAL
UNLOCK
Type 2
ABF
LOCK
OFF
UNLOCK
POWER DOOR LOCK CONTROLLER (CANVAS TOP
MODEL)
1) Disconnect power door lock controller coupler.
2) Connect (+) wire and (±) wire of 12 V battery to terminal ªAº, ªEº
and ªFº as shown in figure.
3) Disconnect cord from terminal ªEº and connect it to terminal ªGº.
4) Repeat Steps 2) and 3) several times and if relay operation is
heard every time, it means that controller is operating.
POWER DOOR LOCK CONTROLLER (HARD TOP MODEL)
1) With the driver side door key turned LOCK, check all power
doors are locked.
2) With the driver side door key turned UNLOCK, check only the
driver side power door is unlocked.
Turn the driver side door key to UNLOCK again within 5 se-
conds, check all power doors are unlocked.
If check result of Step 1) and Step 2) is satisfactory, power door lock
controller is OK. If check result is not satisfactory, go to next Step 3).
3) Disconnect negative cable at battery.
4) Disconnect coupler of power door lock controller.
5) Use a 12 V battery to connect its (+) terminal to terminal E02-1,
and its (±) terminal to terminal E02-2 and E02-3. Check all power
doors are locked.
If check result is not satisfactory, repair circuit and recheck.
If check result is satisfactory, go to next Step 6).
Page 576 of 801
YH4
GRAND
VITARA
Terminal
Key
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-21
6) Connect negative cable at battery.
7) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-7 and
groundAnytime10 ± 14 V
E02-14 and
groundAnytimecontinuity
E02-8 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is LOCK positionContinuity
E02-9 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is UNLOCK positionContinuity
If check result is not satisfactory, repair circuit and recheck.
If check result is satisfactory, replace controller.
KEY CYLINDER SWITCH (DRIVER SIDE)
Check for continuity between terminals according to the key action
shown below.
321
LOCK
OFF
UNLOCK
Page 577 of 801
YH4
GRAND
VITARA
Operation
Terminal Front Door
Rear Door
Back Door (except Canvas Top Model)
LOCK
UNLOCK
LOCK
UNLOCK
LOCK
UNLOCK
8D-22 WINDOWS, MIRRORS, SECURITY AND LOCKS
POWER DOOR LOCK ACTUATOR
1) Disconnect power door lock actuator coupler.
2) Connect 12 V battery positive and negative terminals to the door
lock actuator terminals shown below and check operation.
If it does not operate as specified in table below, replace door
lock actuator.
UNLOCKLOCK
2
3
Page 580 of 801

YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-25
POWER DOOR LOCK ACTUATOR CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller.
3) Use a 12 V battery to connect its (+) terminal to terminal E02-1,
and its (±) terminal to terminal E02-2 and E02-3. Check all power
doors are locked.
If check result is satisfactory, this circuit is OK.
POWER SUPPLY AND GROUNDING CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-7 and
groundAnytime10 ± 14 V
E02-14 and
groundAnytimeContinuity
If check result is satisfactory, this circuit is OK.
DOOR LOCK KEY AND POWER DOOR LOCK SWITCH
CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller.
3) Check for continuity between following terminals at each condi-
tion.
Terminals
ConditionSpecification
E02-8 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is LOCK positionContinuity
E02-9 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is UNLOCK positionContinuity
If check result is satisfactory, this circuit is OK.
Page 581 of 801

YH4
GRAND
VITARA
8D-26 WINDOWS, MIRRORS, SECURITY AND LOCKS
IGNITION SWITCH AND DOOR SWITCH CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-4 and
When ignition switch is OFF
position0 V
groundWhen ignition switch is ON
position10 ± 14 V
E02 10 andWhen all doors are closedNo continuityE02-10 and
groundWhen any one door is
openedContinuity
If check result is satisfactory, this circuit is OK.
DOOR KNOB SWITCH AND TURN SIGNAL RELAY CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-6 and
groundAnytime10 ± 14 V
E02-11 and
When driver side door lock
knob is pulled upContinuity
groundWhen driver side door lock
knob is pushed downNo continuity
If check result is satisfactory, this circuit is OK.