Page 879 of 3371
BL-114
AUTOMATIC BACK DOOR SYSTEM
Revision: August 20072004 QX56
Terminals and Reference Value for BCMEIS002SZ
26 V Back door handle switch signalHandle operation 0
Other 5 Terminal Wire
ColorItem ConditionVoltage (V)
(Approx.)
Terminal Wire
ColorItem ConditionVoltage (V)
(Approx.)
10 G Hazard lamp flash inputBack door active 0
Other 5
22 W/V Power window serial link —
42 GR Glass hatch ajar switchOpen 0
Closed 5
43 R/BBack door latch (door ajar
switch)Open 0
Closed 5
67 B Ground — 0
70 W/B Battery power supply — Battery voltage
PIIA2344E
Page 882 of 3371

AUTOMATIC BACK DOOR SYSTEM
BL-117
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Back Door Power Supply and Ground Circuit InspectionEIS002T2
1. BACK DOOR POWER SUPPLY CIRCUIT INSPECTION
1. Turn ignition switch OFF.
2. Disconnect back door control unit.
3. Check voltage between back door control unit connector B55
terminals 3, 10 and ground.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
2. BACK DOOR GROUND CIRCUIT INSPECTION
Check continuity between back door control unit connector B55 ter-
minal 1, 2 and ground.
OK or NG
OK >> Circuit is OK.
NG >> Repair or replace harness.
During auto closing operations, if obstruction is detected, the
door does not operate in reverse.Back door motor assembly —
During close or cinch operations, the door does not operate in
reverse if the back door handle is operated.Handle switch systemBL-127
When the keyfob is operated, the back door does not operate
automatically.Remote keyless entry system inspectionBL-44Power window serial linkBL-114
Pinch strip system inspectionBL-122
Auto closure does not operate.Half-latch switch systemBL-124Cinch latch motor systemBL-128
Handle switch systemBL-127
The back door does not open.
(Closure motor rotation is not reversed.)Open switch systemBL-125
Handle switch systemBL-127
Warning chime does not sound. Back door warning chime systemBL-123
Auto closure operation works, but the back door is not fully
closedClose switch systemBL-126Handle switch systemBL-127
Cinch latch motor systemBL-128
Back door latch assembly mechanism dam-
aged or worn.— Symptom Suspect systems Refer to
3 (Y/R) - Ground : Approx. battery voltage
10 (L/B) - Ground : Approx. battery voltage
WIIA0567E
1 (B) - Ground : Continuity should exist.
2 (B) - Ground : Continuity should exist.
LIIA0801E
Page 893 of 3371

BL-128
AUTOMATIC BACK DOOR SYSTEM
Revision: August 20072004 QX56
Cinch Latch Motor System InspectionEIS002TC
1. CINCH LATCH MOTOR CIRCUIT INSPECTION
1. Turn ignition switch OFF.
2. Disconnect back door latch and back door control unit.
3. Check continuity between back door control unit connector (A)
B55 terminals 11, 12 and back door latch (cinch latch motor)
connector (B) D503 terminals 1, 2.
4. Check continuity between back door latch (cinch latch motor)
connector (B) D503 terminals 1, 2 and ground.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
2. CINCH LATCH MOTOR OPERATION INSPECTION
Connect battery power to terminals 1 and 2 on the back door latch
and check motor operation.
OK or NG
OK >> GO TO 3.
NG >> Replace the back door latch.
3. CINCH LATCH MOTOR SIGNAL INSPECTION
1. Reconnect back door latch and back door control unit.
2. While fully opening and closing the back door, check voltage
between back door control unit connector B55 terminals 11, 12
and ground.
OK or NG
OK >> Cinch latch motor circuit is OK.
NG >> Replace the back door control unit.1 (L) - 12 (L) : Continuity should exist.
2 (Y) - 11 (Y) : Continuity should exist.
1 (L) - ground : Continuity should not exist.
2 (Y) - ground : Continuity should not exist.
LIIA2263E
1 (+) - 2 (-) : It operates.
1 (-) - 2 (+) : It operates. (Reverse rotation)
LIIA1937E
11 (Y) - Ground
12 (L) - Ground
LIIA0836ESIIA1480E
Page 907 of 3371

BL-142
IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
Revision: August 20072004 QX56
Terminals and Reference Value for BCMEIS002TQ
CONSULT-IIEIS002TR
CONSULT-II INSPECTION PROCEDURE
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carries out CAN communication.
1. Turn ignition switch OFF.
2. Insert IVIS (NATS) program card into CONSULT-II.
3. Connect CONSULT-II and CONSULT-II CONVERTER to data
link connector.
4. Turn ignition switch ON.
5. Touch “START”.
Terminal Wire
ColorItem ConditionVoltage (V)
(Approx.)
21 G NATS antenna amp. Ignition switch (OFF → ON)Just after turning ignition switch
ON: Pointer of tester should move.
23 G/O Security indicator lampGoes OFF → illuminates (Every 2.4
seconds)Battery voltage → 0
25 BR NATS antenna amp. Ignition switch (OFF → ON)Just after turning ignition switch
ON: Pointer of tester should move.
38 W/L Ignition switch (ON or START)Ignition switch (ON or START posi-
tion)Battery voltage
39 W CAN-H — —
40 R CAN-L — —
57 Y/R Battery power supply — Battery voltage
67 B Ground — 0
70 W/B Battery power supply — Battery voltage
Program card : NATS (AEN04A-1) or later
BBIA0369E
PBR4 55 D
Page 911 of 3371

BL-146
IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
Revision: August 20072004 QX56
Trouble DiagnosesEIS002TT
SYMPTOM MATRIX CHART 1
Self-diagnosis related item
*: When IVIS (NATS) detects trouble, the security indicator lights up while ignition key is in the “ON” position.SymptomDisplayed “SELF-DIAG
RESULTS” on CON-
SULT-II screen.Diagnostic Procedure
(Reference page)System
(Malfunctioning part or
mode)Reference Part No. Of
Illustration On System
Diagram
Security indicator
lighting up*
Engine cannot be
startedCHAIN OF ECM-IMMU
[P1612]PROCEDURE 1
(BL-148
)In rare case, “CHAIN OF
ECM-IMMU” might be
stored during key regis-
tration procedure, even if
the system is not mal-
functioning.—
Open circuit in battery
voltage line of BCM cir-
cuitC1
Open circuit in ignition
line of BCM circuitC2
Open circuit in ground
line of BCM circuitC3
Open or short circuit
between BCM and ECM
communication lineC4
ECM B
BCM A
DIFFERENCE OF KEY
[P1615]PROCEDURE 2
(BL-149
)Unregistered key D
BCM A
CHAIN OF IMMU-KEY
[P1614]PROCEDURE 5
(BL-152
)Malfunction of key ID
chipE5
Communication line
between ANT/ AMP and
BCM:
Open circuit or short cir-
cuit of battery voltage
line or ground lineE1
E2
Open circuit in power
source line of ANT/ AMP
circuitE3
Open circuit in ground
line of ANT/ AMP circuitE4
NATS antenna amp. E6
BCM A
ID DISCORD, IMM-ECM
[P1611]PROCEDURE 3
(BL-150
)System initialization has
not yet been completed.F
ECM B
LOCK MODE
[P1610]PROCEDURE 4
(BL-151
)LOCK MODE D
Security indicator light-
ing up*DON'T ERASE
BEFORE CHECKING
ENG DIAGWORK FLOW
(BL-145
)Engine trouble data and
IVIS (NATS) trouble data
have been detected in
ECM—
Page 913 of 3371

BL-148
IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
Revision: August 20072004 QX56
Diagnostic Procedure 1EIS002TU
Self-diagnostic results:
“CHAIN OF ECM-IMMU” displayed on CONSULT-II screen
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagno-
sis of malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BL-142, "
CONSULT-II"
.
1. CONFIRM SELF-DIAGNOSTIC RESULTS
Confirm SELF-DIAGNOSTIC RESULTS “CHAIN OF ECM-IMMU”
displayed on CONSULT-II screen.
NOTE:
In rare case, “CHAIN OF ECM-IMMU” might be stored during key
registration procedure, even if the system is not malfunctioning.
Is CONSULT-II screen displayed as above?
Yes >> GO TO 2.
No >> GO TO BL-146, "
SYMPTOM MATRIX CHART 1" .
2. CHECK POWER SUPPLY CIRCUIT FOR BCM
1. Disconnect BCM.
2. Check voltage between BCM connector M20 terminal 70 and ground.
OK or NG
OK >> GO TO 3.
NG >> Check the following:
50A fusible link (letter f , located in fuse and fusible
link box)
Harness for open or short between fuse and BCM
connector
Ref. Part No. C1
3. CHECK IGN SW. ON SIGNAL
1. Turn ignition switch ON.
2. Check voltage between BCM connector M18 terminal 38 and ground.
OK or NG
OK >> GO TO 4.
NG >> Check the following:
10A fuse [No. 59, located in the fuse and relay box]
Harness for open or short between fuse and BCM
connector
Ref. part No. C2
PIIA1260E
70 (W/B) - Ground : Battery voltage
LIIA1071E
38 (W/L) - Ground : Battery voltage
LIIA0527E
Page 918 of 3371

IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
BL-153
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
4. CHECK POWER SUPPLY FOR NATS ANTENNA AMP.
1. Turn ignition switch ON.
2. Check voltage between NATS antenna amp. connector M21 terminal 1 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace fuse or harness. Ref. part No. E3
5. CHECK NATS ANTENNA AMP. SIGNAL LINE- 1
Check voltage between NATS antenna amp. connector M21 terminal
2 and ground with analog tester.
OK or NG
OK >> GO TO 6.
NG >>
Repair or replace harness. Ref. part No. E1
NOTE:
If harness is OK, replace BCM, refer to BCS-19, "
Removal and Installation of BCM" . Perform
initialization with CONSULT-II. For initialization, refer to “CONSULT-II Operation Manual NATS-
IVIS/NVIS”. 1 (W) - Ground : Battery voltage
LIIA1498E
LIIA1642E
Connector terminals
(wire colors)
Position of ignition key cylinderVoltage (V)
(Approx.)
( + ) ( - )
2 (G) GroundBefore inserting ignition key Battery voltage
After inserting ignition keyPointer of tester should move for approx. 30 seconds,
then return to battery voltage
Just after turning ignition
switch ONPointer of tester should move for approx. 1 second,
then return to battery voltage
Page 919 of 3371

BL-154
IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
Revision: August 20072004 QX56
6. CHECK NATS ANTENNA AMP. SIGNAL LINE- 2
Check voltage between NATS antenna amp. connector M21 terminal
4 and ground with analog tester.
OK or NG
OK >> GO TO 7.
NG >>
Repair or replace harness. Ref. part No. E2
NOTE:
If harness is OK, replace BCM, refer to BCS-19, "
Removal and Installation of BCM" . Perform
initialization with CONSULT-II. For initialization, refer to “CONSULT-II Operation Manual NATS-
IVIS/NVIS”.
7. CHECK NATS ANTENNA AMP. GROUND LINE CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect NATS antenna amp.
3. Check continuity between NATS antenna amp. connector M21 terminal 3 and ground.
OK or NG
OK >> NATS antenna amp. is malfunctioning. Ref. part No. E6
NG >>
Repair or replace harness.
NOTE:
If harness is OK, replace BCM, perform initialization
with CONSULT-II. For initialization, refer to “CON-
SULT-II Operation Manual NATS-IVIS/NVIS”.
LIIA1643E
Connector terminals
(wire colors)
Position of ignition key cylinderVoltage (V)
(Approx.)
( + ) ( - )
4 (BR) GroundBefore inserting ignition key Battery voltage
After inserting ignition keyPointer of tester should move for approx. 30 seconds,
then return to battery voltage
Just after turning ignition
switch ONPointer of tester should move for approx. 1 second,
then return to battery voltage
3 (B) - Ground : Continuity should exist.
LIIA1283E