Page 2197 of 4449
![INFINITI FX35 2004 Service Manual EC-856
[VK45DE]
DTC P0125 ECT SENSOR
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS00C28
CAUTION:
Be careful not to overheat engine.
NOTE:
If DTC Confirmation Procedure has been INFINITI FX35 2004 Service Manual EC-856
[VK45DE]
DTC P0125 ECT SENSOR
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS00C28
CAUTION:
Be careful not to overheat engine.
NOTE:
If DTC Confirmation Procedure has been](/manual-img/42/57021/w960_57021-2196.png)
EC-856
[VK45DE]
DTC P0125 ECT SENSOR
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS00C28
CAUTION:
Be careful not to overheat engine.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Check that “COOLAN TEMP/S” is above 10°C (50°F).
If it is above 10°C (50°F), the test result will be OK.
If it is below 10°C (50°F), go to following step.
4. Start engine and run it for 65 minutes at idle speed.
If “COOLAN TEMP/S” increases to more than 10°C (50°F)
within 65 minutes, stop engine because the test result will
be OK.
5. If DTC is detected, go to EC-856, "
Diagnostic Procedure" .
WITH GST
Follow the procedure “WITH CONSULT-II” above.
Diagnostic ProcedureABS00C29
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-791, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2. CHECK ENGINE COOLANT TEMPERATURE SENSOR
Refer to EC-857, "
Component Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Replace engine coolant temperature sensor.
SEF174Y
PBIB2195E
Page 2198 of 4449
![INFINITI FX35 2004 Service Manual DTC P0125 ECT SENSOR
EC-857
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
3. CHECK THERMOSTAT OPERATION
When the engine is cold [lower than 70°C (158°F)] condition, grasp INFINITI FX35 2004 Service Manual DTC P0125 ECT SENSOR
EC-857
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
3. CHECK THERMOSTAT OPERATION
When the engine is cold [lower than 70°C (158°F)] condition, grasp](/manual-img/42/57021/w960_57021-2197.png)
DTC P0125 ECT SENSOR
EC-857
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
3. CHECK THERMOSTAT OPERATION
When the engine is cold [lower than 70°C (158°F)] condition, grasp lower radiator hose and confirm the engine
coolant does not flow.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace thermostat. Refer to CO-51, "
THERMOSTAT AND WATER CONTROL VALVE" .
4. CHECK INTERMITTENT INCIDENT
Refer to EC-784, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionABS00C2A
ENGINE COOLANT TEMPERATURE SENSOR
1. Check resistance between engine coolant temperature sensor
terminals 1 and 2 as shown in the figure.
*: These data are reference values and are measured between ECM terminal
73 (Engine coolant temperature sensor) and ground.
2. If NG, replace engine coolant temperature sensor.
Removal and InstallationABS00C2B
ENGINE COOLANT TEMPERATURE SENSOR
Refer to CO-51, "THERMOSTAT AND WATER CONTROL VALVE" .
PBIB2005E
Engine coolant
temperature°C (°F)Voltage* V Resistance kΩ
20 (68) 3.5 2.1 - 2.9
50 (122) 2.2 0.68 - 1.00
90 (194) 0.9 0.236 - 0.260
SEF012P
Page 2200 of 4449
![INFINITI FX35 2004 Service Manual DTC P0127 IAT SENSOR
EC-859
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
b. Select “DATA MONITOR” mode with CONSULT-II.
c. Check the engine coolant temperature.
d. If INFINITI FX35 2004 Service Manual DTC P0127 IAT SENSOR
EC-859
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
b. Select “DATA MONITOR” mode with CONSULT-II.
c. Check the engine coolant temperature.
d. If](/manual-img/42/57021/w960_57021-2199.png)
DTC P0127 IAT SENSOR
EC-859
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
b. Select “DATA MONITOR” mode with CONSULT-II.
c. Check the engine coolant temperature.
d. If the engine coolant temperature is not less than 90°C (194°F),
turn ignition switch OFF and cool down engine.
Perform the following steps before engine coolant tempera-
ture is above 90°C (194°F).
2. Turn ignition switch ON.
3. Select “DATA MONITOR” mode with CONSULT-II.
4. Start engine.
5. Hold vehicle speed at more than 70 km/h (43 MPH) for 100 con-
secutive seconds.
6. If 1st trip DTC is detected, go to EC-859, "
Diagnostic Procedure" .
WITH GST
Follow the procedure “WITH CONSULT-II” above.
Diagnostic ProcedureABS00C2F
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-791, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2. CHECK INTAKE AIR TEMPERATURE SENSOR
Refer to EC-841, "
Component Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Replace mass air flow sensor (with intake air temperature sensor).
3. CHECK INTERMITTENT INCIDENT
Refer to EC-784, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
SEF189Y
PBIB2195E
Page 2202 of 4449
![INFINITI FX35 2004 Service Manual DTC P0128 THERMOSTAT FUNCTION
EC-861
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0128 THERMOSTAT FUNCTIONPFP:21200
On Board Diagnosis LogicABS00C2I
Engine coolant te INFINITI FX35 2004 Service Manual DTC P0128 THERMOSTAT FUNCTION
EC-861
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0128 THERMOSTAT FUNCTIONPFP:21200
On Board Diagnosis LogicABS00C2I
Engine coolant te](/manual-img/42/57021/w960_57021-2201.png)
DTC P0128 THERMOSTAT FUNCTION
EC-861
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0128 THERMOSTAT FUNCTIONPFP:21200
On Board Diagnosis LogicABS00C2I
Engine coolant temperature has not risen enough to open the thermostat even though the engine has run long
enough.
This is due to a leak in the seal or the thermostat stuck open.
DTC Confirmation ProcedureABS00C2J
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
For best results, perform at ambient temperature of –10°C (14°F) or higher.
For best results, perform at engine coolant temperature of –10°C (14°F) to 60°C (140°F).
WITH CONSULT-II
1. Replace thermostat with new one. Refer to CO-51, "THERMOSTAT AND WATER CONTROL VALVE" .
Use only a genuine NISSAN thermostat as a replacement. If an incorrect thermostat is used, the MIL may
come on.
2. Turn ignition switch ON.
3. Select “COOLAN TEMP/S” in “DATA MONITOR” mode with CONSULT-II.
4. Check that the “COOLAN TEMP/S” is above 60°C (140°F).
If it is below 60°C (140°F), go to following step.
If it is above 60°C (140°F), cool down the engine to less than 60°C (140°F), then retry from step 1.
5. Drive vehicle for 10 consecutive minutes under the following conditions.
If 1st trip DTC is detected, go to EC-861, "
Diagnostic Procedure" .
WITH GST
1. Follow the procedure “WITH CONSULT-II” above.
Diagnostic ProcedureABS00C2K
1. CHECK ENGINE COOLANT TEMPERATURE SENSOR
Refer to EC-862, "
Component Inspection" .
OK or NG
OK >>INSPECTION END
NG >> Replace engine coolant temperature sensor.
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0128
0128Thermostat functionThe engine coolant temperature does not
reach to specified temperature even though
the engine has run long enough.
Thermostat
Leakage from sealing portion of thermo-
stat
Engine coolant temperature sensor
VHCL SPEED SE 80 - 120 km/h (50 - 75 MPH)
Page 2203 of 4449
EC-862
[VK45DE]
DTC P0128 THERMOSTAT FUNCTION
Revision: 2004 November 2004 FX35/FX45
Component InspectionABS00C2L
ENGINE COOLANT TEMPERATURE SENSOR
Check resistance as shown in the figure.
If NG, replace engine coolant temperature sensor.
Removal and InstallationABS00C2M
ENGINE COOLANT TEMPERATURE SENSOR
Refer to CO-51, "THERMOSTAT AND WATER CONTROL VALVE" .
PBIB2005E
Temperature °C (°F) Resistance kΩ
20 (68) 2.1 - 2.9
50 (122) 0.68 - 1.0
90 (194) 0.236 - 0.260
SEF012P
Page 2204 of 4449
![INFINITI FX35 2004 Service Manual DTC P0132, P0152 HO2S1
EC-863
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0132, P0152 HO2S1PFP:22690
Component DescriptionABS00C2N
The heated oxygen sensor 1 is plac INFINITI FX35 2004 Service Manual DTC P0132, P0152 HO2S1
EC-863
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0132, P0152 HO2S1PFP:22690
Component DescriptionABS00C2N
The heated oxygen sensor 1 is plac](/manual-img/42/57021/w960_57021-2203.png)
DTC P0132, P0152 HO2S1
EC-863
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0132, P0152 HO2S1PFP:22690
Component DescriptionABS00C2N
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1 to 0V.
CONSULT-II Reference Value in Data Monitor ModeABS00C2O
Specification data are reference values.
On Board Diagnosis LogicABS00C2P
To judge the malfunction, the diagnosis checks that the heated oxy-
gen sensor 1 output is not inordinately high.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
Engine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S1 MNTR (B1)
HO2S1 MNTR (B2)LEAN ←→ RICH
Changes more than 5 times
during 10 seconds.
PBIB1847E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0132
0132
(Bank 1)
Heated oxygen sensor
1 circuit high voltageAn excessively high voltage from the sensor is
sent to ECM.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 1 P0152
0152
(Bank 2)
Page 2207 of 4449
EC-866
[VK45DE]
DTC P0132, P0152 HO2S1
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
16 R/LHeated oxygen sensor 1
(bank 1)[Engine is running]
Warm-up condition
Engine speed is 2,000 rpm0 - Approximately 1.0V
(Periodically change)
78 B/RSensor ground
(Heated oxygen sensor)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
Page 2209 of 4449
![INFINITI FX35 2004 Service Manual EC-868
[VK45DE]
DTC P0132, P0152 HO2S1
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground INFINITI FX35 2004 Service Manual EC-868
[VK45DE]
DTC P0132, P0152 HO2S1
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground](/manual-img/42/57021/w960_57021-2208.png)
EC-868
[VK45DE]
DTC P0132, P0152 HO2S1
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS00C2S
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-791, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2. RETIGHTEN HEATED OXYGEN SENSOR 1
1. Loosen and retighten corresponding heated oxygen sensor 1.
>> GO TO 3.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
35 BRHeated oxygen sensor 1
(bank 2)[Engine is running]
Warm-up condition
Engine speed is 2,000 rpm0 - Approximately 1.0V
(Periodically change)
78 B/RSensor ground
(Heated oxygen sensor)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
PBIB2195E
Tightening torque: 50 N·m (5.1 kg-m, 37 ft-lb)
PBIB1520E