INFINITI FX35 2004  Service Manual EC-1042
[VK45DE]
DTC P0461 FUEL LEVEL SENSOR
Revision: 2004 November 2004 FX35/FX45
DTC P0461 FUEL LEVEL SENSORPFP:25060
Component DescriptionABS00C70
The fuel level sensor is mounted in the fuel leve

Page 2385 of 4449

INFINITI FX35 2004  Service Manual EC-1044
[VK45DE]
DTC P0462, P0463 FUEL LEVEL SENSOR CIRCUIT
Revision: 2004 November 2004 FX35/FX45
DTC P0462, P0463 FUEL LEVEL SENSOR CIRCUITPFP:25060
Component DescriptionABS00C75
The fuel level sens

Page 2387 of 4449

INFINITI FX35 2004  Service Manual EC-1046
[VK45DE]
DTC P0500 VSS
Revision: 2004 November 2004 FX35/FX45
DTC P0500 VSSPFP:32702
DescriptionABS00C7A
NOTE:
If DTC P0500 is displayed with DTC U1000 or U1001, first perform the trouble diag

Page 2389 of 4449

INFINITI FX35 2004  Service Manual EC-1048
[VK45DE]
DTC P0506 ISC SYSTEM
Revision: 2004 November 2004 FX35/FX45
DTC P0506 ISC SYSTEMPFP:23781
DescriptionABS00C7F
NOTE:
If DTC P0506 is displayed with other DTC, first perform the trouble

Page 2391 of 4449

INFINITI FX35 2004  Service Manual EC-1050
[VK45DE]
DTC P0507 ISC SYSTEM
Revision: 2004 November 2004 FX35/FX45
DTC P0507 ISC SYSTEMPFP:23781
DescriptionABS00C7J
NOTE:
If DTC P0507 is displayed with other DTC, first perform the trouble

Page 2393 of 4449

INFINITI FX35 2004  Service Manual EC-1052
[VK45DE]
DTC P0550 PSP SENSOR
Revision: 2004 November 2004 FX35/FX45
DTC P0550 PSP SENSORPFP:49763
Component DescriptionABS00C7N
Power steering pressure (PSP) sensor is installed to the power

Page 2398 of 4449

INFINITI FX35 2004  Service Manual DTC P0605 ECM
EC-1057
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0605 ECMPFP:23710
Component DescriptionABS00C7V
The ECM consists of a microcomputer and connectors

Page 2399 of 4449

INFINITI FX35 2004  Service Manual EC-1058
[VK45DE]
DTC P0605 ECM
Revision: 2004 November 2004 FX35/FX45
PROCEDURE FOR MALFUNCTION B
 With CONSULT-II
1. Turn ignition switch ON and wait at least 1 second.
2. Select “DATA MONITOR” m