Page 1659 of 2643

AISIN AUTOMATIC TRANSAXLE 5A2 – 69
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE (DTC) P0743
TORQUE CONVERTER CLUTCH (TCC) ELECTRICAL
Conditions for Setting the DTC
S TCM detects that the ON signal of the lockup sole-
noid monitor during 0.5 seconds when lockup sole-
noid driver outputs the OFF signal.(When the TCC
circuit is open or short to battery).
S The above detection 2 times at shifting continuous-
ly.(When the Tcc circuit is open or short to battery).
S TCM detects that the OFF signal of the lockup sole-
noid monitor during 0.3 seconds when lockup sole-
noid driver outputs the ON signal.(When the TCC
circuit is short to ground).
S The above detection 1 time at shifting continuous-
ly.(When the TCC circuit is short to ground).
Action Taken When the DTC Sets
S TCM will request the illumination of MIL and store
DTC when TCM detects failures on two consecu-
tive ignition cycles.
S No TCC lockup solenoid
S 1st gear fixed under the 10km/hConditions for Clearing the DTC
S The TCM turns off the MIL when no further failures
detected for three consecutive ignition cycles.
S The scan tool can clear the DTC from the TCM his-
tory.
S The TCM clears the DTC from the TCM history
memory after forty consecutive warm up cycles
without fault.
S TCM detects the ON signal of the lockup solenoid
monitor during 160 ms when lockup solenoid driver
outputs the ON signal and TCM detects the OFF
signal of the lockup solenoid monitor during 160 ms
when lockup solenoid driver outputs the OFF sig-
nal.
Cause of Failure
S Wiring harness or connector between lockup sole-
noid and TCM
S Lockup solenoid
S TCM
Page 1662 of 2643

5A2 – 72IAISIN AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE (DTC) P0748
PRESSURE CONTROL SOLENOID (PCS) ELECTRICAL
Conditions for Setting the DTC
S TCM detects that the feed back voltage is greater
than 4.9 volts and detects the detection 500 milli-
seconds continuously.(When the PCS circuit is
short to battery).
S TCM detects that the feed back voltage is less than
70.mV for 70 milliseconds and detects the 12.5
seconds continuously.(When the PCS circuit is
short to ground or open).
Action Taken When the DTC Sets
S TCM will request the illumination of MIL and store
DTC when TCM detects a failure on the first ignition
cycle.
S No lockup control
S No engine torque reduction control
S No engagement pressure control
S No 4th gearS No self–learning control
S After failure decision : emergency mode
Conditions for Clearing the DTC
S The TCM turns off the MIL when no further failures
detected for three consecutive ignition cycles.
S The scan tool can clear the DTC from the TCM his-
tory.
S The TCM clears the DTC from the TCM history
memory after forty consecutive warm up cycles
without fault.
S TCM detects the feed back voltage is between
70mV and 4.9 v for 12.5 seconds continuously.
Cause of Failure
S Wiring harness or connector between Pressure
Control Solenoid (PCS) and TCM
S PCS
S TCM
Page 1665 of 2643

AISIN AUTOMATIC TRANSAXLE 5A2 – 75
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE (DTC) P0751
SHIFT SOLENOID 1 (SS1) STUCK OFF
Conditions for Setting the DTC
S Shift Solenoid 1 (SS1) is stuck ON/OFF.
S D range selected
S Engine water normal temperature
S 20 seconds have passed since the transaxle was
placed in D.
S Engine revolution is 600 rpm or greater.
S No failure of output speed sensor / input speed
sensor / engine revolution / water temperature sig-
nal / solenoid electrical / ranger sensor / throttle
signal
Action Taken When the DTC SetsS TCM will request the illumination of MIL and store
DTC when TCM detects failures on two consecu-
tive ignition cycles.
Conditions for Clearing the DTC
S The TCM turns off the MIL when no further failures
detected for three consecutive ignition cycles.
S The scan tool can clear the DTC from the TCM his-
tory.
S The TCM clears the DTC from the TCM history
memory after forty consecutive warm up cycles
without fault.
Cause of Failure
S Shift Solenoid 1 (SS1)
S Inside Valve Body
S TCM
Page 1667 of 2643

AISIN AUTOMATIC TRANSAXLE 5A2 – 77
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE (DTC) P0753
SHIFT SOLENOID 1 (SS1) ELECTRICAL
Conditions for Setting the DTC
S TCM detects that the ON signal of the Shift Sole-
noid 1 (SS1) monitor during 0.5 seconds when SS1
driver outputs the OFF signal.(When the SS1 circuit
is open or short to battery).
S TCM detects that the OFF signal of the Shift Sole-
noid 1 (SS1) monitor during 0.3 seconds when SS1
driver outputs the ON signal.(When the SS1 circuit
is short to ground).
S The above detection 2 times at shifting continuous-
ly.
Action Taken When the DTC Sets
S TCM will request the illumination of MIL and store
DTC when TCM detects a failure on the first ignition
cycle.
S No lockup control
S No engine torque reduction control
S No engagement pressure control
S No timing solenoid control for N–D
S No self–learning control
S After failure decision : emergency modeTCM Shifting Pattern (Range : D)
Normal
SS1 FAIL
GearSS1SS2GearSS1SS2
1 stONON3 rdFAILOFF
2 ndONOFF3 rdFAILOFF
3 rdOFFOFF3 rdFAILOFF
4 thOFFON4 thFAILON
Conditions for Clearing the DTC
S The TCM turns off the MIL when no further failures
detected for three consecutive ignition cycles.
S The scan tool can clear the DTC from the TCM his-
tory.
S The TCM clears the DTC from the TCM history
memory after forty consecutive warm up cycles
without fault.
S TCM detects the ON signal of the SS1 monitor dur-
ing 160 ms when SS1 driver outputs the ON signal
and TCM detects the OFF signal of the SS1 moni-
tor during 160 ms when SS1 driver outputs the
OFF signal.
Page 1670 of 2643

5A2 – 80IAISIN AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE (DTC) P0756
SHIFT SOLENOID 2 (SS2) STUCK OFF
Conditions for Setting the DTC
S Shift Solenoid 2 (SS2) is stuck ON/OFF.
S D range selected
S Engine water normal temperature
S 20 seconds have passed since the transaxle was
placed in D.
S Engine revolution is 600 rpm or greater.
S No failure of output speed sensor / input speed
sensor / engine revolution / water temperature sig-
nal / solenoid electrical / ranger sensor / throttle
signalAction Taken When the DTC Sets
S TCM will request the illumination of MIL and store
DTC when TCM detects failures on two consecu-
tive ignition cycles.
Conditions for Clearing the DTC
S The TCM turns off the MIL when no further failures
detected for three consecutive ignition cycles.
S The scan tool can clear the DTC from the TCM his-
tory.
S The TCM clears the DTC from the TCM history
memory after forty consecutive warm up cycles
without fault.
Cause of Failure
S Shift Solenoid 2 (SS2)
S Inside Valve Body
S TCM
Page 1672 of 2643

5A2 – 82IAISIN AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE (DTC) P0758
SHIFT SOLENOID 2 (SS2) ELECTRICAL
Conditions for Setting the DTC
S TCM detects that the ON signal of the Shift Sole-
noid 2 (SS2) monitor during 0.5 seconds when SS2
driver outputs the OFF signal.(When the SS2 circuit
is open or short to battery).
S TCM detects that the OFF signal of the Shift Sole-
noid 2 (SS2) monitor during 0.3 seconds when SS2
driver outputs the ON signal.(When the SS2 circuit
is short to ground).
S The above detection 2 times at shifting continuous-
ly.
Action Taken When the DTC Sets
S TCM will request the illumination of MIL and store
DTC when TCM detects a failure on the first ignition
cycle.
S No lockup control
S No engine torque reduction control
S No engagement pressure control
S No timing solenoid control for N–D
S No self–learning control
S After failure decision : emergency modeTCM Shifting Pattern (Range : D)
Normal
SS2 FAIL
GearSS1SS2GearSS1SS2
1 stONON2 ndONFAIL
2 ndONOFF2 ndONFAIL
3 rdOFFOFF3 rdOFFFAIL
4 thOFFON3 rdOFFFAIL
Conditions for Clearing the DTC
S The TCM turns off the MIL when no further failures
detected for three consecutive ignition cycles.
S The scan tool can clear the DTC from the TCM his-
tory.
S The TCM clears the DTC from the TCM history
memory after forty consecutive warm up cycles
without fault.
S TCM detects the ON signal of the SS2 monitor dur-
ing 160 ms when SS2 driver outputs the ON signal
and TCM detects the OFF signal of the SS2 moni-
tor during 160 ms when SS2 driver outputs the
OFF signal.
Page 1675 of 2643

AISIN AUTOMATIC TRANSAXLE 5A2 – 85
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE (DTC) P0785
TIMING SOLENOID (ST) ELECTRICAL
Conditions for Setting the DTC
S TCM detects that the ON signal of the Timing Sole-
noid (ST) monitor during 0.5 seconds when ST driv-
er outputs the OFF signal.(When the ST circuit is
open or short to battery).
S TCM detects that the OFF signal of the Timing So-
lenoid (ST) monitor during 0.1 seconds when ST
driver outputs the ON signal.(When the ST circuit is
short to ground).
S The above detection 3 times at shifting continuous-
ly.
Action Taken When the DTC Sets
S TCM will request the illumination of MIL and store
DTC when TCM detects a failure on the first ignition
cycle.
S After failure decision : emergency modeConditions for Clearing the DTC
S The TCM turns off the MIL when no further failures
detected for three consecutive ignition cycles.
S The scan tool can clear the DTC from the TCM his-
tory.
S The TCM clears the DTC from the TCM history
memory after forty consecutive warm up cycles
without fault.
S TCM detects the ON signal of the ST monitor dur-
ing 100 ms when ST driver outputs the ON signal
and TCM detects the OFF signal of the ST monitor
during 160 ms when ST driver outputs the OFF sig-
nal.
Cause of Failure
S Wiring harness or connector between Timing Sole-
noid (ST) and TCM
S ST
S TCM
Page 1678 of 2643
5A2 – 88IAISIN AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE (DTC) P1781
ENGINE TORQUE SIGNAL ERROR
Conditions for Setting the DTC
S TCM detects that malfunction of engine speed sig-
nal for 2 seconds.
S No DTC U2105
Action Taken When the DTC Sets
S TCM will request the illumination of MIL and store
DTC when TCM detects a failure on the first ignition
cycle.
S No engine torque reduction control
S No engagement pressure control
S No 4th gear
S No self–learning controlConditions for Clearing the DTC
S The TCM turns off the MIL when no further failures
detected for three consecutive ignition cycles.
S The scan tool can clear the DTC from the TCM his-
tory.
S The TCM clears the DTC from the TCM history
memory after forty consecutive warm up cycles
without fault.
Cause of Failure
S Wiring harness or connector between ECM and
TCM
S ECM
S TCM