Page 278 of 523

Downloaded from www.Manualslib.com manuals search engine 274
INJECTION
PARTICLE FILTER SAFETY AND CLEANLINESS REQUIREMENTS
Operations on the fuel additive circuit.
IMPERATIVE: For all operations on the additive circuit, wear protective goggles and gloves that are resistant to hydrocarbons.
The work area must be ventilated.
In the event of any significant dispersion of additive:
Wear a breathing mask for filtering the particles.
Recover as much of the product as possible.
Place the product thus recovered in an appropriately labelled container. Wash the soiled area with copious amounts of water.
Dispose of materials and solid residues in an authorised recovery point.
IMPERATIVE:The filling kit should be recycled following a repair. All «Eolys» additive containers that have been opened should be
disposed of.
Cleanliness rules.
ESSENTIAL: The operator should wear clean overalls.
Before working on the injection circuit, it may be necessary to clean the unions of the following sensitive components(see corresponding operations).
Fuel filter.
Fuel high pressure pump.
Fuel high pressure regulator.
Fuel high pressure common injection rail. Fuel high pressure piping. Diesel injector carriers.
IMPERATIVE: After dismantling, immediately blank the unions of the sensitive components with plugs, to prevent any ingress of impurities.
ALL TYPES
Page 490 of 523
Downloaded from www.Manualslib.com manuals search engine 486
ELECTRICAL
SYSTEM
MANULLI calibrated seal (3).
Direction of fitting of the seal (3).
Before fitting the seal, amply lubricate the seal with air conditioningcompressor oil
(SP10). The condenser
(5)has a cylinder (6)incorporating the function of aircon
fluid reservoir and with integral filtering cartridge.The inlet
(7)and the outlet (8)of the condenser (5)are equipped with
new seals (3) (MANULLI).
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Seals (MANULLI seal)
Condenser (MANULLI seal)
C5HP18VDC5HP18XD
C2 C3 XSARA PICASSO
Page 495 of 523

Downloaded from www.Manualslib.com manuals search engine 491
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Refitting.
Remove the new cartridge from its packaging.
Do not expose the cartridge, the filter and seals to pollutants.
Lightly oil the seals
(compressor oil).
Remove tool [5] from the reservoir (6).
Insert the new cartridge (5)into the reservoir (6).
Refit the safety circlip (4), using tool [6].
Make sure that the circlip (4)is correctly positioned in its location.
WARNING: Not more than 5 minutes should elapse between the removal of
the cartridge (6) from its packaging and its being fitted.
Refit:
The plastic cap (3), using tool [5] Tighten to 1,2 ±0,1 m.daN.
The condenser (reclip, pushing at «b»and «c»).
The plastic cover and the pins at «a».
The grille (2).
The screws (1).
Proceed to:
Recharge the circuit
(see corresponding operation).
Check the operation of the air conditioning (see corresponding operation).
C4AP167CC4AP165CC4AP164CC4AP163C
C2 C3 C3 PLURIEL
Page 499 of 523
Downloaded from www.Manualslib.com manuals search engine 495
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Move aside the radiator/condenser assembly.
Remove the plug (6), using tool [2].
Support the radiator/condenser assembly thus moved aside.
Remove the filtering/drying cartridge
(7), using pliers.
Refitting.Refit the filtering/drying cartridge (7).
Clean the threads of the plug (6).
It is essntial to change the O ring seals (8).
Lubricate the O ring seals (8)with aircon compressor oil.
Refit:
The plug
(6), using tool [2], tighten to 1,4 ±0,2 m.daN.
The brackets (5).
The screws (4).
The cardboard from the radiator harness.
The nuts
(1).
The air filter assembly (3).
Couple the hose (2).
Recharge the circuit (R134.a) (according to equipment)
(see corresponding operation).
Check the operation of the air conditioning.
C5HP14NCC5HP14PCC5HP14QC