Downloaded from www.Manualslib.com manuals search engine 491
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Refitting.
Remove the new cartridge from its packaging.
Do not expose the cartridge, the filter and seals to pollutants.
Lightly oil the seals
(compressor oil).
Remove tool [5] from the reservoir (6).
Insert the new cartridge (5)into the reservoir (6).
Refit the safety circlip (4), using tool [6].
Make sure that the circlip (4)is correctly positioned in its location.
WARNING: Not more than 5 minutes should elapse between the removal of
the cartridge (6) from its packaging and its being fitted.
Refit:
The plastic cap (3), using tool [5] Tighten to 1,2 ±0,1 m.daN.
The condenser (reclip, pushing at «b»and «c»).
The plastic cover and the pins at «a».
The grille (2).
The screws (1).
Proceed to:
Recharge the circuit
(see corresponding operation).
Check the operation of the air conditioning (see corresponding operation).
C4AP167CC4AP165CC4AP164CC4AP163C
C2 C3 C3 PLURIEL