Page 490 of 523
Downloaded from www.Manualslib.com manuals search engine 486
ELECTRICAL
SYSTEM
MANULLI calibrated seal (3).
Direction of fitting of the seal (3).
Before fitting the seal, amply lubricate the seal with air conditioningcompressor oil
(SP10). The condenser
(5)has a cylinder (6)incorporating the function of aircon
fluid reservoir and with integral filtering cartridge.The inlet
(7)and the outlet (8)of the condenser (5)are equipped with
new seals (3) (MANULLI).
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Seals (MANULLI seal)
Condenser (MANULLI seal)
C5HP18VDC5HP18XD
C2 C3 XSARA PICASSO
Page 495 of 523

Downloaded from www.Manualslib.com manuals search engine 491
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Refitting.
Remove the new cartridge from its packaging.
Do not expose the cartridge, the filter and seals to pollutants.
Lightly oil the seals
(compressor oil).
Remove tool [5] from the reservoir (6).
Insert the new cartridge (5)into the reservoir (6).
Refit the safety circlip (4), using tool [6].
Make sure that the circlip (4)is correctly positioned in its location.
WARNING: Not more than 5 minutes should elapse between the removal of
the cartridge (6) from its packaging and its being fitted.
Refit:
The plastic cap (3), using tool [5] Tighten to 1,2 ±0,1 m.daN.
The condenser (reclip, pushing at «b»and «c»).
The plastic cover and the pins at «a».
The grille (2).
The screws (1).
Proceed to:
Recharge the circuit
(see corresponding operation).
Check the operation of the air conditioning (see corresponding operation).
C4AP167CC4AP165CC4AP164CC4AP163C
C2 C3 C3 PLURIEL
Page 499 of 523
Downloaded from www.Manualslib.com manuals search engine 495
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Move aside the radiator/condenser assembly.
Remove the plug (6), using tool [2].
Support the radiator/condenser assembly thus moved aside.
Remove the filtering/drying cartridge
(7), using pliers.
Refitting.Refit the filtering/drying cartridge (7).
Clean the threads of the plug (6).
It is essntial to change the O ring seals (8).
Lubricate the O ring seals (8)with aircon compressor oil.
Refit:
The plug
(6), using tool [2], tighten to 1,4 ±0,2 m.daN.
The brackets (5).
The screws (4).
The cardboard from the radiator harness.
The nuts
(1).
The air filter assembly (3).
Couple the hose (2).
Recharge the circuit (R134.a) (according to equipment)
(see corresponding operation).
Check the operation of the air conditioning.
C5HP14NCC5HP14PCC5HP14QC
XSARA PICASSO
Page 500 of 523

Downloaded from www.Manualslib.com manuals search engine 496
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Compressor lubricant
ESSENTIAL: The compressor lubricant is extremely hygroscopic; always use FRESH oil.
Checking the compressor oil level
There are three specific cases:
1/
Repairs to a system without leaks.2/Slow leak.3/Fast leak.
1/ Repairing a system without leaks.
a)Using draining/recovery equipment not fitted with an oil decanter.
Drain the system as slowly as possible via the LOW PRESSUREvalve, so as not to lose any oil.
No more oil should be added when filling the system with
R 134.a fluid.
b) Using draining/filling equipment fitted with an oil decanter. Drain the R 134.afluid from the system in accordance with the instructions in the equipment handbook.
Measure the amount of oil recovered.
Add the same amount of
NEWoil when filling the system with R 134.afluid.
c) Replacing a compressor. Remove the old compressor, drain it and measure the oil quantity.
Drain the new compressor (supplied full), so that the same amount of NEWoil is left in the compressor as was in the old compressor.
No more oil should be added when filling the system with R 134.afluid.
AIRCONAIRCON
Page 501 of 523